Figure D: Lower End
_______________________________________________________________________________________________
1: Choke Valve
The Choke Valve is normally fully open. The Choke Valve, when closed,
directs the air stream through the Pressure Vessel and can be used to clean
out the Feed Unit. The choke valve in the closed position causes sponge
media to quickly exit the Feed Unit.
1
4
5
2
2: Air Motor Moisture Separator
The Air Motor Moisture Separator, which automatically drains when full,
protects the air motor from excess moisture.
3
3: Air Motor Lubricator
The Air Motor Lubricator injects oil automatically from a reservoir into the
air stream.
1
6
4: Auger Tunnel End Cap
The Auger Tunnel End Cap allows access to the auger for cleaning purposes.
5: Blast Hose Connection
The Blast Hose Connection is a two-pronged universal Blast Hose connector
fitting, which allows for connection from the Blast Hose to the Feed Unit.
6: Clean Out Trap
The Clean Out Trap is removable to check for obstructions at the Auger.
Figure D
Sponge-Jet B-VAC User Manual – 10-February-2005
Page 33 of 55