6. THE TEST LABEL Every time the printer is switched on it will print a label with a whole series of data on the status of the printer. The following is a sample of a test label and the most important points are explained. The Programming Manual gives a complete description of each of the values contained in the test label. EPROM Version ST314 25 E1.4 Printer serial number 00000 066 003 047 07:47:43 Mer 08-Mar-2000 Max. label length Serial speed >T314210423792B583808100004390439 Ymax:297 mm. Mem:512 kb >S64001040101000 >B28N1 >A00 >C/ >L000 P150150255255255 P150H0256 G00330000N00000000 *02 K1001J1510V08105600 PWM:623 – 20.49 mV. $&%0000000000000000 08:print speed 10:paper feed speed Photosensor 5: strobe speed selected 600:print power set Label offset 623:effective print power 20.49:printhead tension in mV Value of selected photosensor The effective print power is different to that set if the temperature control is activated. Activating the temperature control continually regulates the printing power. The Programming manual gives an extensive explanation of the significance of all of the above parameters. It is advisable to keep a test label once the printer has been installed . This will be useful in the event that the printer configuration changes for any reason and it will then be possible to reconfigure it using the information from the test label. 10