Download CE MultiTester MI 2094 User Manual
Transcript
CE MultiTester MI 2094 User Manual Version 5.0, Code No. 20 750 799 Distributor: TOLEKA AB – Fenix väg 28 – 134 44 GUSTAVSBERG – 08-574 103 50 Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail: [email protected] © 2002, 2004 METREL No part of this publication may be reproduced or utilized in any form or by any means without permission in writing from METREL. 2 MI 2094 CE MultiTester General presentation 1. General presentation ............................................................................................................. 4 Safety in use ............................................................................................................................. 4 1.2 Warranty.............................................................................................................................. 5 1.3. List of measurements carried out by the instrument................................................ 7 1.4 List of applicable standards ........................................................................................... 7 2. Description of the instrument.............................................................................................. 8 3. Technical specifications.....................................................................................................10 3.1. Withstanding test (PROG.HV and HV position)........................................................10 3.2. Burn out (HV position)...................................................................................................11 3.3. Low resistance (Continuity position)..........................................................................11 3.4. Voltage drop scaled to 10 A~ (option in Continuity position).................................12 3.5. Insulation resistance.....................................................................................................14 3.6. Leakage current .............................................................................................................14 3.7. Substitute leakage current ...........................................................................................15 3.8. Touch leakage current ..................................................................................................15 3.9. Functional test ................................................................................................................16 3.10. Discharge time (DISC.TIME position)......................................................................17 3.11. General..........................................................................................................................18 4. Measurements ......................................................................................................................19 4.1. Withstanding test: ..........................................................................................................19 4.2. Withstanding test with preset voltage/time diagram:..............................................25 4.3. Low resistance test with currents of 0.1A / 0.2A / 10A / 25A~ ...............................27 4.4. Voltage drop scaled to test current of 10 A~ .............................................................30 4.5. Insulation resistance.....................................................................................................31 4.6. Discharge time - external (input MAINS TEST).........................................................36 4.7. Discharge time-internal................................................................................................38 4.8. Leakage current .............................................................................................................40 4.9 Subtitute leakage current...............................................................................................42 4.10 Touch leakage current.................................................................................................43 4.11. Functional test..............................................................................................................45 4.12. Autotest..........................................................................................................................48 5. Operation ................................................................................................................................53 5.1. Warnings .........................................................................................................................53 5.2. Memorizing results ........................................................................................................54 5.3. Recalling of stored results...........................................................................................57 5.4. RS 232 Communication...............................................................................................58 5.5. System configuration.....................................................................................................59 5.6. Contrast of the display ..................................................................................................62 5.7. Use of remote control pedal ........................................................................................63 5.8. Use of WARNING LAMP................................................................................................65 5.9. Use of barcode reader..................................................................................................66 5.10. Use of EXT/DOOR input .............................................................................................67 5.10.1. DOOR input ...............................................................................................................67 5.10.2 EXTERNAL input........................................................................................................67 6. Maintenance...........................................................................................................................70 6.1. Metrological check .........................................................................................................70 6.2. Service..............................................................................................................................70 3 MI 2094 CE MultiTester General presentation 6.3. Cleaning ..........................................................................................................................70 6.4. Replacing the fuses ( properly trained service personnel only!) ..........................70 7. PC Software - CE Link..........................................................................................................72 7.1. Installing CE Link...........................................................................................................72 7.2. Introduction notes ..........................................................................................................72 7.3. Download data ...............................................................................................................74 7.4. Open data file..................................................................................................................77 7.5. Printing documents .......................................................................................................80 7.5.1 Printing selected rows................................................................................................80 7.5.2 Print separately ............................................................................................................82 7.6. Header programming ...................................................................................................83 7.7. Sequence editor.............................................................................................................84 1. General presentation Safety in use • Use the instrument in accordance with the manual, otherwise the instrument • • • • • • • may be dangerous for the operator! Read this instruction manual carefully, otherwise use of the instrument may be dangerous for the operator, for the instrument or for equipment under test! Use only grounded mains outlets to supply the instrument! Do not use any damaged mains outlet or damaged mains connection cable! A competent authorized person must only carry out Service or calibration procedure! Only a skilled person, who is familiar with hazardous voltage operations, can handle CE MultiTester! Disconnect all unused test leads before starting measurement; otherwise the instrument can be damaged! In case of failure of the instrument test results may be impaired. It is a good practice to regularly confirm/check the accuracy of the tester (by simple field calibration, comparison to known reference values etc). Meaning of , signs on front panel: Insulation section Dangerous voltage may be present; measurements shall be carried out only on de-energized object Continuity section Measurements shall be carried out only on de-energized object. Read instructions on how to replace blown-up fuse., measurements shall be carried 4out only on de-energized object. MI 2094 CE MultiTester General presentation instructions on how to replace blown-up fuse., measurements shall be carried out only on de-energized object. Withstanding section Dangerous voltage may be present., Sswitch off the instrument immediately if the red warning lamp (fig. 1., pos. 12, fig.1.) does not light after switching on HV generator, and service the instrument. Always handle as the test leads are energized. Touch Leakage Current TEST SOCKET 230V / 16A 50Hz Dangerous voltage is present on the TEST SOCKET (fig.1., pos.10, fig.1.) after pressing the START/STOP push button, . Main plug 230V~ / 50Hz 16A MAIN F1 F2,5A/250V MAIN F2 F2,5A/250V TEST SOCKET F3 T16A/250V TEST SOCKET F4 T16A/250V Dangerous voltage is present on the FUSES fuses. - sSwitch off the instrument and disconnect all test cables and mains cord before replacing the fuses or opening the instrument. 1.2 Warranty Unless stated differently, our instruments are guaranteed against any manufacturing or material defect. They do not bear the specification known as the safety specification. Our guarantee, which may not under any circumstances exceed the amount of the invoiced price, is for the repair of our faulty equipment only, carriage paid to our workshops. It is applicable for normal use of our instruments and does not 5 MI 2094 CE MultiTester General presentation apply to any damage or destruction caused, notably by error in mounting, mechanical accident, faulty maintenance, defective use, overload or excess voltage. Our responsibility is strictly limited to the pure and simple replacement of the faulty parts of our equipment; the buyer expressly renounces any attempt to find u s responsible for damages or losses caused directly or indirectly.Our guarantee is applicable for twelve (12) months after the date at which the equipment is made available. The repair, modification or replacement of a part during the guarantee period will not result in this guarantee being extended. 6 MI 2094 CE MultiTester General presentation 1.3. List of measurements carried out by the instrument • • • • • • • • • Withstanding programmed voltage - time sequence test Withstanding voltage test High voltage burn-out test Continuity test Voltage drop test Insulation resistance test Leakage current tests (leakage, substitute, touch) Functional tests (power, voltage, current, cos _, frequency) Discharge time measurement 1.4 List of applicable standards CE MultiTester is designed in accordance with the following standards: • • EN 61010-1 ............ safety EN 61326................ electromagnetic compatibility Measurements in compliance with: • • • • • • • • • • • • • EN 60204-1 ............ Electrical equipment of machines EN 60335-1 ............ Household and similar electrical appliances EN 60439-1 ............ Switch-gear and control-gear assemblies EN 60598-1 ............ Luminaries IEC 60745............... Hand-held motor-operated tools IEC 60755............... Residual current operated protect. devices EN 60950................ Safety of information technology equipment EN 61010-1 ............ Safety requirements for electrical equipment IEC 61029............... Transportable motor-operated tools EN 61558-1 ............ Transformers and power supply units EN 60065................ Audio, video, and similar electronic apparatus VDE 701 T1............. Repair and modification inspections VDE 702 T1............. Repeat tests of electrical appliances The CE MultiTester instrument supply upper standards up to 16 A according to its maximum power capability. Measurements according to standards above are possible only up to 16 A ( maximum power capability of the CE MultiTester). 7 MI 2094 CE MultiTester Description of the instrument 2. Description of the instrument RS232C CE MultiTester ISO + MI2094 1000V= WARNING LAMP 12V~ / 0,3A EXT / DOOR IN REMOTE BAR-CODE READER 600 Vmax CAT III 300V DISCHARGING TIME Touch Leakage Current TEST SOCKET 230V~ / 50Hz 16A 230V / 16A 50Hz MAIN F1 F2,5A/250V MAIN F2 F2,5A/250V TEST SOCKET F3 T16A/250V TEST SOCKET F4 T16A/250V I F1 F2 F3 F4 MEM HELP RS232 SET CONTINUITY P1 10V 25A~ C2 O P2 LEAK.CURRENT ISO TEST ON C1 CONTINUITY FUNCTIONALITY HV DISC.TIME PROG.HV WITHSTANDING AUTOTEST 5KV~ Fig.1. Front panel layout Legend: 1 ...... REMOTE connector to connect REMOTE CONTROL PEDAL 2 ...... WARNING LAMP connector to connect WARNING LAMP 3 ...... RS 232 connector to connect external printer or PC 4 ...... EXT/DOOR IN connector 5 ...... BAR CODE READER connector 6 ...... LCD dot matrix display with continuous backlight 7 ...... Positive INSULATION test terminal 8 ...... Grounded INSULATION test terminal 9 ...... DISCHARGE TIME-TEST test terminals 10.... TEST SOCKET 230V /16A 11.... TOUCH LEAKAGE test terminal 12 CONTINUITY test terminals (current test terminals C1, C2, and potential test terminals P1, P2) 13.... WITHSTANDING test terminals 8 MI 2094 CE MultiTester Description of the instrument 14.... SET key (press when the instrument is switched ON): • Set date / time • Set serial port baud rate • Set barcode reader baud rate • Clear records memory • Clear devices / records • Clear program memory • Load default setting • INPUT DOOR IN disabled / enabled • EARTH CONTROL disabled / enabled 15.... RS232 key: • Select RS 232 communication mode • Transmit memorized data to PC 16.... ROTARY SWITCH to select desired function 17.... HELP key: 18.... MEM key: • Memorize results • Recall memorized results 19 General keys F1 to F4 (function of each key is shown on display) 20.... START/STOP push button 21.... TEST ON warning lamp 22.... POWER ON/OFF switch with indication lamp 23.... T16A 250V 6.3x 32 fuses protect test socket from overloading 24.... F 2.5A 250V fuses protect instrument’s power supply 25.... Mains connector 9 MI 2094 CE MultiTester Technical specifications 3. Technical specifications 3.1. Withstanding test (PROG.HV and HV position) Nominal test voltage: adjustable (100 V÷ 5000) V / (50 Hz, 60) Hz at Umains = 230 V, Pload = 500 VA Open circuit test voltage:............Un (nominal test voltage) (-1 % / +10 %) at Umains = 230 V Output dDifferential output:........2 HV plugs Voltage shape: ............................sinusoidal Test voltage readout Range (kV) 0.100 ÷ 0.999 1.000 ÷ 5.000 Resolution (kV) 0.001 0.001 Accuracy ± (2 % of reading + 5 dig.) ± (3 % of reading + 5 dig.) Two different voltage procedure modes: • Standard voltage mode • Programmable voltage mode (parameters t1, t2, t3, U1, U2) Trip-out out test current for nominal test voltages up to 1000 V adjustable to 0.5*, 1.0*, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 450, 500 mA. * except inat Autotest For test voltages greater than 1000 V, maximum current limit depends on max high voltage power characteristic (500 VA = max. power). Accuracy of trip-out test current:.........±10 % of set value. Test current readout (sin wave) *0.0 ÷ 500.0 Resolution (mA) 0.1 0.0 ÷ 500.0 0.1 Range (mA) Accuracy ± (5 % of reading + 5 digit) absolute value ± (30 % of reading +10 digit) resistive or capacitive value** * (1.5 -– 500) mA inat Autotest ** not displayed at ‘Trip out ’ STOP IIIARC=+22 Absolute value of test current is always displayed ( selected resistive ( ) or capacitive ( ) component. ) together with Maximum Ttrip out time: < 30 ms after break through. Timer: adjustable 1 s - 9 min 59 s with resolution of 1 s. Timer OFF function available. 10 MI 2094 CE MultiTester Technical specifications 3.2. Burn out (HV position) Selectable voltage ..................................................(100 V÷ 5000) V Minimum burn out time before overheating: ......10 s I max.:.........................................................................(50 mA ÷ 60) mA 3.3. Low resistance (Continuity position) Resistance readout for currents 10 A and 25 A Range R (Ω)* 0.000 ÷ 0.999 1.000 ÷ 2.000 2.001 ÷ 9.999 * autoranging Resolution (Ω) Accuracy 0.001 0.001 0.001 ± (3 % of reading + 3 dig.) ± (3 % of reading + 10 dig.) indicator only Resolution (Ω) Accuracy 0.01 0.1 ± (5 % of reading + 12 dig.) ± (5 % of reading + 6 dig.) Resistance readout for current 0.10 A Range R (Ω)* 0.00 ÷ 9.99 10.0 ÷ 100.0 * autoranging Resistance readout for current 0.20 A Range R (Ω)* 0.00 ÷ 9.99 10.0 ÷ 100.0 * autoranging Resolution (Ω) Accuracy 0.01 0.1 ± (5 % of reading + 6 dig.) ± (5 % of reading + 6 dig.) Max. output voltage:........................................<6 V∼ Measuring current (electronically stabilized) selectable 100 mA, 200 mA, 10 A, 25 A - 100 mA at R < 50 Ω (Umains : 230 V, original test leads) - 200 mA at R < 8 Ω (Umains : 230 V, original test leads) - 10 A ............ at R < 0.5 Ω (Umains : 230 V, original test leads) - 25 A ............ at R < 0.2 Ω (Umains : 230 V, original test leads) Current shape:................................................sinusoidal Threshold Limit value adjustable:...............10 mΩ ÷ 1.0 Ω (in steps of 10 mΩ ), 1.0 Ω ÷ 2.0 Ω (in steps of 100 mΩ), or ignored (*** Ω sign is selected) Timer:................................................................adjustable 1 s ÷ 59 s, resolution 1 s Connectionsystem:.......................................4 wire, safety connectors, electrically separated 11 MI 2094 CE MultiTester Technical specifications Test voltage readout with currents 10 A and 25 A Range (V) 0.000 – 10.000 Resolution (V) 0.001 Accuracy ± (3 % of reading + 0.05 V) Test voltage readout with currents 0.1 A and 0.2 A Range (V) 0.000 – 10.000 Resolution (V) 0.001 Accuracy ± (5 % of reading + 0.1 V) Test current readout 10 A and 25 A Range (A) 0.0 – 30.0 Resolution (A) 0.1 Accuracy ± (3 % of reading + 5 dig.) Test current readout 0.1A and 0.2A Range (A) 0.000 – 1.000 Resolution (A) 0.001 Accuracy ± (5 % of reading + 5 dig.) 3.4. Voltage drop scaled to 10 A~ (option in Continuity position) Voltage drop readout (scaled to 10A~) Range ΔU (V) 0.00 – 10.00 10.00 – 99.99 Resolution (V) 0.01 0.01 Accuracy ± (3 % of reading + 3 dig.) indicator only Resolution (A) 0.1 Accuracy ± (3 % of reading + 3 dig.) Test current readout Range (A) 0.0 – 30.0 ThresholdLimit value of voltage drop versus wire section: 2 ThresholdLimit voltage drop (V) 5.0 5.0 3.3 2.6 1.9 1.4 1.0 Wire section (mm ) 0.5 0.75 1 1.5 2.5 4 ≥6 Any of the wire sections in the previous table can be selected in order to evaluate voltage drop result. 12 MI 2094 CE MultiTester Technical specifications 13 MI 2094 CE MultiTester Technical specifications Max. output voltage:.....................10 V∼ Electronically stabilized current Current shape:.............................sinusoidal Measuring current (external resistance. of (0.0 Ω - 0.5) Ω connected to original test cable):..........................................>10 A∼ Timer:.............................................adjustable (1 s - 59) s, resolution 1 s Connection system:....................4 wire, safety connectors, electrically separated 3.5. Insulation resistance • Nominal voltage 250 V, 500 V, 1000 V Insulation resistance readout: Range* (MΩ) 0.000 - 1.999 2.000 – 199.9 Resolution ** (MΩ) 0.001 0.001, 0.01, 0.1 200 - 999 1 Accuracy ± (5 % of reading + 10 dig.) ± (3 % of reading + 3 dig.) ± (10 % of reading + 10 dig.) * autoranging, depends on test voltage ** depends on test voltage Measuring range (stable and accurate result even with capacitive load): .. (0 MΩ - 1) MΩ Nominal voltage:............(250 V, 500 V, 1000) V (+30 % / - 0 %) Short circuit current: ......3.5 mA max. Measuring current: ........1 mA min. at (250 kΩ / 250 V, 500 kΩ / 500 V, 1000) kΩ / 1000 V Settable limits: ...............0.2 MΩ - 200.0 MΩ (resolution 0.1 MΩ), no limit (*** MΩ sign is selected) Timer:...............................adjustable 1 s - 9 min 59 s with resolution of 1 s Timer OFF function available. Subresult:........................measuring voltage Output: .............................2 safety plugs, grounded Auto-discharge after test. 3.6. PE leakage current Leakage current readout: Range (mA) 0.00 – 3.99 4.0 – 20.0 Resolution (mA) 0.01 0.1 Accuracy ± (5 % of reading + 3 dig.) ± (5 % of reading + 3 dig.) Settable limits: .............................(0.1 mA – 20.0) mA (in step of 0.1 mA) Output: ...........................................16 A power test socket 14 MI 2094 CE MultiTester Technical specifications Timer:.............................................adjustable 1 s - 9 min 59 s with resolution 1 s Timer OFF function available. Frequency response………….complies to EN61010-Figure A1 3.7. Substitute leakage current Substitute leakage current readout: Range (mA) 0.00 – 20.0 Resolution (mA) 0.01 Accuracy ± (5 % of reading + 3 dig.) Settable limits: .............................no, (0.1 mA – 20.0) mA (in step of 0.1 mA) Short circuit current: ....................< 30 mA Open circuit voltage:....................40 V Output: ...........................................16 A power test socket Displayed current is calculated to 230 V. Frequency response………….complies to EN61010-Figure A1 3.8. Touch leakage current Touch leakage current readout: Range (mA) 0.00 – 2.00 Resolution (mA) 0.01 Accuracy ± (5 % of reading + 3 dig.) Settable limits: .............................no, (0.1 mA – 2.0) mA (in step of 0.1 mA) Output: ...........................................16 A power test socket + TOUCH safety plug RAmeter: 2 k_ Frequency response………….complies to EN61010-Figure A1 15 MI 2094 CE MultiTester Technical specifications 3.9. Functional test Active Power, Apparent Power, Voltage, Current and Frequency monitoring on the test socket: Active Power, Apparent Power Range (W) 0 – 199.9 200 – 3500 Resolution (W) 0.1 1 Accuracy ± (5 % of reading + 10 digit) ± (5 % of reading + 3 digit) Resolution (V) 1 Accuracy ± (2 % of reading + 2 digit) Resolution (A) 0.001 0.01 Accuracy ± (3 % of reading + 5 dig.) ± (5 % of reading + 5 dig.) Resolution 0.01 Accuracy ± (3 % of reading + 3 dig.) Resolution (Hz) 0.01 Accuracy ± (0.1% of reading +3 dig.) Test voltage readout Range (V) 0 – 400 V Test current readout Range (A) 0 – 0.999 1.00 – 15.99 Cos _ readout Range 0 – 1.00 Frequency readout Range (Hz) 45.00 – 65.00 ThresholdLimit Apparent Power:.......adjustable (10 VA ÷ 3500) VA (10 VA ÷ 100) VA (resolution 1 VA) (100 VA ÷ 3500) VA (resolution 10 VA) Output: ....................................................16 A power test socket Timer: adjustable 1 s - 9 min 59 s with resolution 1 s Timer OFF function available. 16 MI 2094 CE MultiTester Technical specifications 3.10. Discharge time (DISC.TIME position) • Discharge time on power plug (external) Max. working voltage......................................750V p Min. working voltage.......................................(70 Vp, 140) V p Measuring range ............................................(0 s - 10) s Resolution .......................................................0.1 s ThresholdLimit of discharging time............1 s Accuracy ...........................................................±(2 % of reading + 0.2 s) Safe voltage level............................................60 V, 120 V Internal resistance of input...........................96 MΩ • Discharge time on internal electronic components (internal) Max. working voltage......................................750 V p Min. working voltage.......................................(70 Vp, 140) V p Measuring range ............................................(0 s - 10) s Resolution ......................................................0.1 s ThresholdLimit of discharging time............5 s Accuracy ...........................................................±(2% of reading + 0.2 s) Safe voltage level............................................60 V, 120 V Internal resistance of input...........................96 MΩ 17 MI 2094 CE MultiTester Technical specifications 3.11. General Mains voltage: ..............................230 V (-10 % ÷ +6 %) / (50 Hz, 60) Hz Max. power consumption:..........660 VA (without load on TEST SOCKET) Max. power consumption:..........3.85 kVA (with load on TEST SOCKET) Display:..........................................LCD dot matrix, (160 x 116) dots with cont. backlight RS232 interface:..........................1 start bit, 8 data bits, 1 stop bit RS232 baud rate adjustable:....9600, 19200, 38400 Baud Memories:.....................................1638 memory locations Remote control signals:.............START / STOP, SAVE EXT/ Door in signals:..................Next test, Pass / Fail result, External input, Door in Bar code reader:..........................EAN13 Bar code baud rate adjustable: 2400, 4800 or 9600 Baud Measurement circuitry protection: F1.......F 2.5 A / 250 V (5 mm × 20) mm) (general protection of the instrument) F2.......F 2.5 A / 250 V (5 mm × 20) mm) (general protection of the instrument) F3.......T 16 A / 250 V (6.3 mm × 32 mm) (test socket protection) F4.......T 16 A / 250 V (6.3 mm× 32 mm) (test socket protection) Note ! For correct operation of the instrument fuses F3 and F4 must be in good condition because the test socket is the point from which the instrument observes the input voltage (zero crossing for soft start of internal generator). Case: ................................................................shock proof plastic / portable Dimensions (w × h × d):...............................(410 m m× 175 mm× 370) mm Mass (without accessories):........................13.5 kg Pollution degree: ............................................2 Degree of protection (at closed cover): ......IP 50 Overvoltage category:.....................................Cat III / 300V, Cat II / 600V Protection classification:...............................I Working temp. range: ....................................(0 0C ÷ +40) 0C Ref. temp. range:............................................(+105 0C ÷ +3530) 0C Ref. humidity range:.......................................(+40 RH ÷ +70) % RH Storage temp. range:.....................................(-10 0C ÷+ 60) 0C Max. working humidity:...................................85% RH (0 0C ÷ +40) 0C) Max. storage humidity:...................................90% RH (-10 0C ÷ +40) 0C) 80% RH (+40 0C ÷ +60) 0C) Accuracies apply for 1 year in reference conditions. Temperature coefficient outside this limits is 0.1% of measured value per 0C° and 1 digit. Withstanding proof test: • Between mains and withstanding terminals 7500 Veff / 1 min • Between mains and other terminals or accessible metallic parts 2200 Veff / 1 min 18 MI 2094 CE MultiTester Measurements 4. Measurements 4.1. Withstanding test: Warning ! • • • • • • • Disconnect all unused test leads before starting measurement; otherwise the instrument can be damaged! Only a skilled person, who is familiar with hazardous voltage operations, can perform this measurement! Check instrument and test leads for any sign of damage or abnormality before connecting them to the instrument. DO NOT use test probes in case of any damage or abnormality! Always handle the instrument and connected accessories as the Withstanding test sockets and leads are under the hazardous voltage! Never touch exposed probe tip, connected equipment under test, or any other energized part during the measurements. Make sure that NOBODY else can contact them either! Connect test probes only for withstanding measurement, and disconnect them immediately after the test! DO NOT touch any part of test probe in front of the barrier (keep your fingers behind the finger guards on of the probe) – possible danger of electric shock! Always set the lowest possible trip-out current. HV (high voltage) position OBJECT UNDER TEST CE MultiTester MI2094 iC (0 - 230) V/ (50, 60)Hz regulated iR 100V - 5 kV V C LOAD A Fig. 2. Test circuitry 19 iA RLOAD MI 2094 CE MultiTester Measurements iR 0 Re iA i= i +C i A R i.....absolute value of test current A iC i.....capacitive current C i.....resistive current R -jIm Fig. 3. Test current diagram How to carry out the measurement STEP 1. Set rotary switch to HV (high voltage) position. The following heading is displayed: Function name Tripping out current Nominal test voltage Leakage current (main result) Character of selected part of leakage current Selected (resistive or capacitive) part of leakage current Set timer value Test voltage Timer key to set timer value or to switch it on/off Un key to select nominal test voltage Burn key to set burn mode Ilim key to select tripping out current or to select character of displayed leakage current Fig. 4. Main menu in HV function STEP 2. • Select test parameters as follows: Test voltage - Use U N key to select appropriate test voltage that can be set using ↑ ↓ keys from 100 V to 1000 V in 10 V steps and from 1000 V to 5000 V in 50 V steps. 20 MI 2094 CE MultiTester Measurements Selected test voltage Fig. 5. Test voltage selection menu - Press Exit key to exit Test voltage selection menu. • Trip-out current / character of displayed part of leakage current - Press Ilim key in order to reach menu for trip-out current selection and character of displayed part of leakage current (resistive or capacitive). See the following figure. Selected tripping out current Absolute value of test current Character of selected part of leakage current Fig. 6. Trip-out current selection menu - Use ↑ and ↓ keys to select appropriate trip-out current. Press Chr I in order to change the character of displayed part of leakage current. If the selected part is resistive, sign is displayed behind mA unit. For capacitive part sign is displayed behind mA unit. Press Exit key to exit Trip-out current selection menu. NOTE ! The set thresholdLimit value of test current is always compared with the absolute value of test current. 21 MI 2094 CE MultiTester • Measurements Timer value / timer OFF/ON - Press Timer key and the menu for timer value selection is displayed. Use ↑ and ↓ keys to select appropriate test time value. To deactivate the timer press Toff key or Ton key to activate it. See the following figure. After pressing Toff key After presing Toff key test time is not displayed To activate timer press Ton key Fig. 7. Timer value selection menu - • Press Exit key to exit Timer value selection menu. BURN mode - Press Burn key to select Burn out mode. In this mode current is limited only by the internal generator characteristics. Instead of tripping out current value BURN message is displayed Press Ilim key to cancel Burn mode Fig. 8. Main menu in HV function when the BURN mode is selected NOTE ! The result of BURN test cannot be saved 22 MI 2094 CE MultiTester STEP 3. Measurements Connect test probes (pistols) to the instrument as shown in figure below. Fig. 9. Connection of test probes STEP 4. Close DOOR IN