Download Start 2012 - User manual

Transcript
Laying Multiple Modes
It is only possible to associate the Multiple Laying concept with the “Semiautomatic section
selection” and “Automatic section selection” modes.
Operation is very simple: setting Serial at the end of a first cable laying operation, the command
continues considering the previous destination symbol (or point) as start for a new cable laying (with
the same characteristics) consecutive to the one that has just been made.
Setting Parallel at the end of a first cable laying operation, the command continues considering the
previous start symbol (or point) as start for a new cable laying.
In practice it allows you to continue laying the same cables without quitting the function.
Appropriate use of the multiple cable laying
function allows considerable time saving during
operations for drafting the cables in the sections.
The following figures show us some examples of application:
Serial
The bundle of cables 3(1x2.5) is laid
between the various symbols using serial
multiple laying.
In the initial laying SB1 was selected as start
element and EL1 as destination, then from
EL1 to EL2 as new destination, then from
EL2 to EL3 …
It should be noted that the same cable
bundle has been laid in each section.
Parallel
The bundle of cables 3(1x2.5) has been laid
between the various symbols using parallel
multiple laying.
In the initial laying E1 was selected as start
element and XS1 as destination, then still
from E1 to XS2 as new destination, then
from E1 to XS3 …
It should be noted that 3 cable bundles have
been laid in the initial section, in the next one
2 ...
Multiple laying is not allowed using the “Select section manually” mode.
19 Cables • 317