Download Operating Instructions - Cont
Transcript
5 I Startup Starting the motor 0 The following travel cycle shows by way of example how the motor is started with the assignment of terminals X12:1 … X12:4 and analog setpoints. Binary output X10:3 (DBØØ "/Brake") is used for switching brake contactor K12. "1" Input DIØØ /Controller inhibit "0" "1" Input DIØ1 CW/Stop "0" "1" Input DIØ2 CCW/Stop "0" "1" Input DIØ3 Enable / Stop "0" Output DBØØ /Brake "1" "0" 10V Analog input n1 (AI11) 5V 0V n [rpm ] nmax Speed 50 % nmax nmin nstart-stop 0 -50 % nmax t11 up t11 up t11 up t11 down t11 down t11 up Stop ramp t13 -nmax NOTE The motor is not energized in the event of controller inhibit. A motor without brake will coast to standstill. 62 Operating Instructions – MOVITRAC® B