Download User Manual Interroll DriveControl

Transcript
DriveControl HC-EC100 / HC-EC110
Product information
'LUHFWLRQRIWUDYHO
5HYHUVHGLUHFWLRQRIWUDYHO
52//(5
'5,9(
External direction set in NPN mode
6PDUW)ZGLQ
5HYLQ
6HQVRULQ
*1'
9'&
*1'
9'&
WRGRZQVWUHDP=3$FDUG
5(9LQ
WRXSVWUHDP=3$FDUG
9'&
*1'
):'LQ
DIP switch settings:
• SW5: ON / OFF (If SW5 is ON, direction setting is transferred downstream.)
• SW4: ON / OFF (If SW4 is ON, direction setting is transferred upstream.)
• SW3: ON / OFF (If REV signal is active, SW3 has to be OFF.)
• SW2: ON / OFF
• SW1: OFF
Start options:
• FWD connected to GND at NPN mode causes ccw rotation.
• REV connected to GND at NPN mode causes cw rotation.
• FWD and REV connected to GND at NPN mode causes coast mode.
Hint
• FWD signal acts like a jog signal, disregarding ZPA functionality and
photoeye signals.
• REV signal reverses motor and logic direction; upstream becomes
downstream and C sensor becomes B sensor.
22
Version 1.0 (11/2007) en
Original language