Download Operators Manual
Transcript
CxHy : Unburnt HydroCarbon reading in % of LEL of Methane, the sensor is calibrated with Methane. Displayed when a HydroCarbon sensor fitted. LEL is the Lower Explosive Limit of a gas when mixed with air, for Methane this has the ratio of 19:1 Air:Methane. Below the LEL the mixture can not ignite and burn. In the Flue an unburnt HydroCarbons should be well below this level or there is the potential for an explosion. LOSS : Total losses calculated from Combustion Theory. This is the summation of the next three parameters. DRY : Calculated heat lost in turning the Carbon in the fuel to Carbon Dioxide (CO2). WET : Calculated heat lost in turning the Hydrogen in the fuel into water (H2O). CO LOSS % : Calculated loss due to partially burnt Carbon. Any Carbon Monoxide (CO) in the flue has the potential to be turned into Carbon Dioxide and release more heat, hence this heat is lost up the flue. OS11 % : Oxygen sensor life indicator. This is an approximation calculated from the output voltage of the sensor in fresh air. Note ! This is not valid when a combustion test is being performed. H2xc : The Carbon Monoxide sensor is Hydrogen compensated. This parameter is the reading from the Hydrogen sensor built into CO sensor. It is an indication of the level if Hydrogen in the flue and can NOT be used as an exact level, it is only used to cross compensate the CO sensor. AUX1 : Auxilliary sensor position, to be used for future sensors. KM9106 Operators Manual 59