TRAK-IT TOOL MODEL C3, C3 ST
TROUBLESHOOTING
SYMPTOM
POSSIBLE PROBLEMS
SERVICE
1a. Inoperative indicator lights on
charger.
1a. Try Battery in tool after 3 hours on charge cycle.
If tool functions properly charger lights are not
working correctly. Replace charger, or monitor
charging time to ensure Battery Cell has adequate
time for recharging. It's normal for Battery to feel
warm after properly charging.
1b. Damaged charger.
1b. Discontinue use immediately and unplug from
power source. Replace charger and tag or dispose
of charger to prevent accidental reuse or connection
to power source.
2a. Red and green LEDs on charger
are blinking alterately.
2a. Battery is hot.
2a. Remove battery from charger and allow to cool.
2b. Red and green LEDs on charger
are blinking simultaneously.
2b. Battery damaged or cycle life
exhausted.
2b. Replace Battery .
1a. Battery is not charged.
1a. Charge Battery according to Operating Manual.
Preparing Tool for Operation –
Battery/Charger Problems
1. Battery Cell does not appear to
accept charge. Green charger light
does not come on after several
hours.
Normal Stage of Operation
1. Fan does not run.
1b. Battery Terminals or Handle battery
contacts are oily, dirty, or corroded.
1b. Clean Battery Cell terminals Clean Handle Battery
Cell contacts as required
1c. There is electrical short somewhere.
1c. The tool must be looked into by an Authorized
Powers Fasteners Service Technician.
2. Fan does not run, or runs slower
than normal.
2. Battery is discharged
2. Charge Battery Cell.
3. Fan runs intermittently.
3. Battery is loose or contacts are bent.
3. Snap battery back into its locked position. Bend
contacts back into proper position.
1a. Lockout Bar is stuck in lockout
position.
1a. Check safety cam bushing screw for excessive
tightness. Open nose piece door if necessary and
clean out build-up of debris from track
1b. Contact Arm is bent, or build-up of
debris in track restricts operation.
1b. Inspect Contact Arm for cleanliness and possible
damage. Clean track with cloth. If Contact Arm is
damaged return to Authorized Powers Fasteners
Customer Service Representative for Service.
1c. Follower is not behind strip.
1c. Put follower behind strip.
1d. Cylinder head O-Ring pinched.
1d. Contact Authorized Powers Fasteners Customer
Service Representative for service.
2a. Fuel Cell is empty.
2a. Replace Fuel Cell.
2b. Spark wire out of spark plug.
2b. Contact Authorized Powers Fasteners Distributor
Customer Service Representative for service.
2c. Spark does not occur.
2c. Contact Authorized Powers Fasteners Customer
Service Representative for service.
19
Pre-Combustion/Combustion
Stage of Operation
1. Contact Arm does not depress
fully--tool does not operate.
2. Tool will not cycle--fan runs.
19