Transcript
SANDTOFT ROOF TILE FIXING SPECIFICATIONS - ZONAL METHOD Lindum Tiles - with counterbattens Site altitude: 0 - 100 m Headlap 75 mm 100mm Pitch 35-44º 45-55º Below 35º Below 35º 35-44º Zone 1 5m E D D D D 10 m E D D D D 15 m E D D D D Zone 2 5m E D D D D 10 m E D D D D 15 m D E D D D Zone 3 For Zone 3 calculation to BS 6399 and BS 5534 is required. Site altitude: 100 - 200 m Headlap 75 mm 100mm Pitch Below 35º 35-44º 45-55º Below 35º 35-44º Zone 1 5m E D D D D 10 m D E D D D 15 m D D E D D Zone 2 5m E D D D D 10 m E D E E D 15 m D E D E E Zone 3 For Zone 3 calculation to BS 6399 and BS 5534 is required. Site altitude: 200 - 300 m Headlap 75 mm 100mm Pitch Below 35º 35-44º 45-55º Below 35º 35-44º Zone 1 5m D D D E D 10 m D D D E D 15 m E D E E D Zone 2 5m D D E E D 10 m E D E E D 15 m E* D E E* D Zone 3 For Zone 3 calculation to BS 6399 and BS 5534 is required. 45-55º E E E E E E 45-55º E E E E E E 45-55º E E E E E E Site altitude: > 300 m Calculation to BS 6399 and BS 5534 is required. Zonal fixing specifications Key A No fixings required B Each tile once nailed (right hand hole on flat tiles) C Each tile twice nailed (flat tiles only) D Each tile clipped E Each tile once nailed and clipped F Each tile twice nailed and clipped X Wind uplift force exceeds tile resistance (contact Sandtoft's Technical Team on 0870 1452021) * = Improved Nail 20