Download Operating Instructions for ZHRV5 Series Relay Single
Transcript
IEC60947-5-1 Operating Instructions for ZHRV5 Series Relay Single-phase voltage control relay Function Features 35mm symmetrical DIN rail conforming to EN/IEC 60715 Mounting support Controls its own supply voltage(True RMS measurement). User may select operation mode through knob. Measuring frequency range:45Hz-65Hz,DC. Panel Diagram The relay is only 18mm wide. ZHRV5-01 panel description: Voltage measurement accuracy <1%. Control status is indicated by a LED. The relays are designed for clip-on mounting on rail. U> U< Applications 2 Over/under voltage fault LED.UE UE U 40 50 60 Protect electrical equipment and motors from over-voltage and under-voltage. Normal/emergency power supply switching. 30 70 20 80V AC/DC H 10 12 14 8 6 5 Model and Connotation Tt / ZHRV5 1 Relay output and time delay LED.R/T R/T 3 Operating function selector knob (overvoltage/undervoltage, locking/non-locking) 4 Voltage threshold adjusting knob.U 16 18 20% 4 5 Hysteresis control knob.H 6 2 8 0.1 10s 6 Time delay control knob . Tt ZHRV5-01 Rated supply voltage codes (see Table 2) Function code(see Table 1) ZHRV5-02 panel description: ZHRV5 series relay Table 1 Function code Overvoltage U>40 50 60 ● ● ZHRV5-02 30 70 <U 20 80V AC/DC Supply voltage limits Range of adjustment D12 DC 12V DC 7...20V DC 9...15V AD48 AC/DC 24...48V AC /DC15...100V AC/DC 20...80V AD240 AC/DC 110...240V AC/DC 50...270V AC/DC 65...260V A220 AC 220V AC 160...270V AC 180...260V 4 Over voltage threshold adjusting knob .U> 30 70 20 80V AC/DC Tt Rated supply voltage 3 Undervoltage fault LED.U< U<40 50 60 Table 2 Rated supply voltage code 2 Overvoltage fault LED.U> >U Over / undervoltage in windows mode ZHRV5-01 1 Relay output and time delay LED.R/T R/T Undervoltage 4 5 Under voltage threshold adjusting knob .U< 6 2 8 0.1 10s 6 Time delay control knob . Tt ZHRV5-02 LED functions Table 3 R / T:yellow LED Function Technical Parameters Output relay energized DC12V,AC/DC24...48V,AC/DC110V...240V , AC220V Rated supply frequency 50/60Hz +-10%,0 Tripping delay ZHRV5-01:5...20%of threshold setting Overvoltage Hysteresis ZHRV5-02:3%fixed of threshold setting Adjustable 0.1...10s,10% Measurement error <1%over the whole range with voltage variation Run up delay at power up 0.5s time delay Konb setting accuracy 1%of scale value Reset delay 1000ms Rated insulation voltage 460V IP degree of protection IP20 Pollution degree 3 Electrical durability 100000 cycles U<:red LED Setting error Rated supply voltage Time delay U>:red LED UE:red LED Undervoltage Knob for setting of threshold value 11 12 13 40 50 60 10 14 30 70 9 15V DC 20 80V AC/DC D12 AD48 220 220 230 210 240 200 250 260V 180 AC 140 160 180 200 120 100 220 240 80 260V 65 AC/DC Mechanical durability 1000000 cycles Height above sea level <=2000m Operation temperature -5...40℃ Relative humidity <=50%(40℃) Storage temperature -25...75℃ Conventional heat current 5A U>40 50 60 Utilisation category AC-15 30 70 30 70 Contact capacity Ue/Ie:250V/1.5A 20 80V 20 80V Output type 1/CO AD240 A220 U> -1- U< U<40 50 60 R 12 11 14 Function Diagrams Operating Instructions ZHRV5-01 ZHRV5-01 Un 1.Select operating function selector knob ;the relay takes a reading of operating functions after power-on.In case of knob setting error, LED will flash at the same time, which indicate the setting error. Normal operation will be resumed through resetting after power-off. If the operating function is changed after power-on, all LED indicators would flash while the relay operates based on original operating functions;the LED would resume the normal indication after the original setting is recovered. 2.Regulate the Voltage threshold adjusting knob to set protection threshold value. 3.Regulate the h ysteresis control knob ; hysteresis is 5%...20%of threshold value. 4.When measured volte exceeds the set threshold value of voltage,R/T LED would flash and the UE LED would go ON . When fault time exceeds the set time delay(0.1s...10s) interval,output relay would be disconnected and R/T LED would go OFF. 5.When "over-voltage, non-locking" mode is activated, if the operating voltage is less than the difference between voltage threshold value and lagged value , the output relay would be actuated and the R / T LED would go ON . When "under-voltage, non-locking" mode is activated, if the operating voltage is more than the sum of voltage threshold value and lagged value, the output relay would be actuated and the R / T LED would go ON . 6.In case of "locking" mode, the operating voltage exceeds threshold value and output relay would keep an off-state. The power must be turned off before resetting the relay. U< U> U> H U LED:R / T LED : UE Overvoltage, non - locking mode 11 U< U> Tt 14 12 <Tt Un U> H U LED:R / T Overvoltage, locking mode LED:UE 11 Undervoltage, non-locking mode ZHRV5-02 1.Regulate the overvoltage and undervoltage threshold adjusting knob threshold value . The set overvoltage threshold value must be larger than undervoltage threshold value. Otherwise, all LEDs would flash and the output relay would be disconnected. 2.Fixed Hysteresis is 5% . 3.When measured voltage exceeds the threshold value, R/T LED would flash and the U> (U<) LED would go ON. When fault time exceeds the set time delay(0.1s...10s) interval, output relay would be disconnected and R/T LED would go OFF. 4.When operating voltage is lower than the difference between overvoltage threshold value and lagged value or higher than the sum of undervoltage and lagged value,the output relay would be actuated and the R / T LED would go ON . Note: hysteresis = set threshold value * set hysteresis value . Un U H U< U< U> Tt 14 12 LED : R / T LED:UE 11 <Tt Tt 14 12 Overall Dimensions A1 Us U H U< U< U> A2 R U> U< R/T UE Undervoltage, locking mode U 40 50 60 LED:R / T LED:UE 11 70 30 20 H 10 12 14 8 6 5 Tt 14 12 Tt 80V AC/D C 16 18 20% 4 6 2 8 0.1 10s ZHRV5-01 ZHRV5-02 12 U> H H U< 18±0 . 3 Wiring Diagram U LED:R / T L N LED:U> LED:U< 11 14 66.2max 68.5max 14 11 Tt Tt <Tt F1 <Tt A1+ 12 U> :Overvoltage threshold U< :Undervoltage threshold H :Hysteresis U :Controlled signal Tt :Delay on threshold crossing 12 A212 11 R 14 11 14 Warning 1. This product shall be installed , operated and maintained by professional personnel. 2 . Whether or not the product functions normally , user shall not dismantle or repair the said product without permission, and we shall not assume any responsibility for the accident as a result thereof. 3 . Please refer to the wiring diagram in Operation Instructions when arranging wires. 4 . Never place power input line in the same conduit with other wires with heavy current. Please use shielded wire if necessary so as not to bring about interference that may influence the normal operation of relay. 5 . Do not use this product in areas with dust , corrosive gases and with exposure to direct sunlight and rain. 6 . Never use this product in medium with explosion hazard and with gases that may corrode metals and destroy the insulation, and do not use this product in a space with conductive dust. 7 . Please store and use this product at rated supply voltage and stated temperature , height above sea level and humidity . 8 . Failure to follow these instructions can result in death, serious injury, or equipment damage. 9. The warranty period of this product shall be 18 months under normal use . -2-