Download Operating Instructions for ZHRV5 Series Relay Single

Transcript
IEC60947-5-1
Operating Instructions for ZHRV5 Series Relay
Single-phase voltage control relay
Function Features
35mm symmetrical DIN rail conforming to
EN/IEC 60715
Mounting support
Controls its own supply voltage(True RMS measurement).
User may select operation mode through knob.
Measuring frequency range:45Hz-65Hz,DC.
Panel Diagram
The relay is only 18mm wide.
ZHRV5-01 panel description:
Voltage measurement accuracy <1%.
Control status is indicated by a LED.
The relays are designed for clip-on mounting on
rail.
U>
U<
Applications
2 Over/under voltage fault LED.UE
UE
U 40 50 60
Protect electrical equipment and motors from over-voltage and
under-voltage.
Normal/emergency power supply switching.
30
70
20
80V
AC/DC
H 10 12 14
8
6
5
Model and Connotation
Tt
/
ZHRV5
1 Relay output and time delay LED.R/T
R/T
3 Operating function selector knob
(overvoltage/undervoltage, locking/non-locking)
4 Voltage threshold adjusting knob.U
16
18
20%
4
5 Hysteresis control knob.H
6
2
8
0.1
10s
6 Time delay control knob . Tt
ZHRV5-01
Rated supply voltage codes (see Table 2)
Function code(see Table 1)
ZHRV5-02 panel description:
ZHRV5 series relay
Table 1
Function code
Overvoltage
U>40 50 60
●
●
ZHRV5-02
30
70 <U
20
80V
AC/DC
Supply voltage
limits
Range of
adjustment
D12
DC 12V
DC 7...20V
DC 9...15V
AD48
AC/DC 24...48V
AC /DC15...100V
AC/DC 20...80V
AD240
AC/DC 110...240V
AC/DC 50...270V
AC/DC 65...260V
A220
AC 220V
AC 160...270V
AC 180...260V
4 Over voltage threshold adjusting knob .U>
30
70
20
80V
AC/DC
Tt
Rated supply
voltage
3 Undervoltage fault LED.U<
U<40 50 60
Table 2
Rated supply
voltage code
2 Overvoltage fault LED.U>
>U
Over / undervoltage in windows mode
ZHRV5-01
1 Relay output and time delay LED.R/T
R/T
Undervoltage
4
5 Under voltage threshold adjusting knob .U<
6
2
8
0.1
10s
6 Time delay control knob . Tt
ZHRV5-02
LED functions
Table 3
R / T:yellow LED
Function
Technical Parameters
Output relay
energized
DC12V,AC/DC24...48V,AC/DC110V...240V , AC220V
Rated supply frequency
50/60Hz +-10%,0
Tripping delay
ZHRV5-01:5...20%of threshold setting
Overvoltage
Hysteresis
ZHRV5-02:3%fixed of threshold setting
Adjustable 0.1...10s,10%
Measurement error
<1%over the whole range with voltage variation
Run up delay at power up
0.5s time delay
Konb setting accuracy
1%of scale value
Reset delay
1000ms
Rated insulation voltage
460V
IP degree of protection
IP20
Pollution degree
3
Electrical durability
100000 cycles
U<:red LED
Setting error
Rated supply voltage
Time delay
U>:red LED
UE:red LED
Undervoltage
Knob for setting of threshold value
11
12 13
40
50 60
10
14
30
70
9
15V
DC
20
80V
AC/DC
D12
AD48
220 220 230
210
240
200
250
260V
180
AC
140 160 180
200
120
100
220
240
80
260V
65
AC/DC
Mechanical durability
1000000 cycles
Height above sea level
<=2000m
Operation temperature
-5...40℃
Relative humidity
<=50%(40℃)
Storage temperature
-25...75℃
Conventional heat current
5A
U>40 50 60
Utilisation category
AC-15
30
70
30
70
Contact capacity
Ue/Ie:250V/1.5A
20
80V
20
80V
Output type
1/CO
AD240
A220
U>
-1-
U<
U<40 50 60
R
12
11
14
Function Diagrams
Operating Instructions
ZHRV5-01
ZHRV5-01
Un
1.Select operating function selector knob ;the relay takes a reading of operating functions after power-on.In case of knob setting error, LED will flash at the same time, which indicate the setting error. Normal operation will be resumed through resetting after power-off. If the operating function is
changed after power-on, all LED indicators would flash while the relay operates based on original operating functions;the LED would resume the normal indication after the original setting is recovered.
2.Regulate the Voltage threshold adjusting knob to set protection threshold
value.
3.Regulate the h ysteresis control knob ; hysteresis is 5%...20%of threshold
value.
4.When measured volte exceeds the set threshold value of voltage,R/T
LED would flash and the UE LED would go ON . When fault time exceeds the set time delay(0.1s...10s) interval,output relay would be disconnected and R/T LED would go OFF.
5.When "over-voltage, non-locking" mode is activated, if the operating voltage is less than the difference between voltage threshold value and lagged
value , the output relay would be actuated and the R / T LED would go
ON . When "under-voltage, non-locking" mode is activated, if the operating
voltage is more than the sum of voltage threshold value and lagged value,
the output relay would be actuated and the R / T LED would go ON .
6.In case of "locking" mode, the operating voltage exceeds threshold value
and output relay would keep an off-state. The power must be turned off before resetting the relay.
U<
U>
U>
H
U
LED:R / T
LED : UE
Overvoltage,
non - locking mode
11
U<
U>
Tt
14
12
<Tt
Un
U>
H
U
LED:R / T
Overvoltage,
locking mode
LED:UE
11
Undervoltage,
non-locking mode
ZHRV5-02
1.Regulate the overvoltage and undervoltage threshold adjusting knob threshold value . The set overvoltage threshold value must be larger than undervoltage threshold value. Otherwise, all LEDs would flash and the output relay would be disconnected.
2.Fixed Hysteresis is 5% .
3.When measured voltage exceeds the threshold value, R/T LED would flash
and the U> (U<) LED would go ON. When fault time exceeds the set time delay(0.1s...10s) interval, output relay would be disconnected and R/T LED
would go OFF.
4.When operating voltage is lower than the difference between overvoltage
threshold value and lagged value or higher than the sum of undervoltage
and lagged value,the output relay would be actuated and the R / T LED
would go ON .
Note: hysteresis = set threshold value * set hysteresis value .
Un
U
H
U<
U<
U>
Tt
14
12
LED : R / T
LED:UE
11
<Tt
Tt
14
12
Overall Dimensions
A1
Us
U
H
U<
U<
U>
A2
R
U>
U<
R/T
UE
Undervoltage,
locking mode
U 40 50 60
LED:R / T
LED:UE
11
70
30
20
H 10 12 14
8
6
5
Tt
14
12
Tt
80V
AC/D C
16
18
20%
4
6
2
8
0.1
10s
ZHRV5-01
ZHRV5-02
12
U>
H
H
U<
18±0 . 3
Wiring Diagram
U
LED:R / T
L
N
LED:U>
LED:U<
11
14
66.2max
68.5max
14
11
Tt
Tt
<Tt
F1
<Tt
A1+
12
U> :Overvoltage threshold
U< :Undervoltage threshold
H :Hysteresis
U :Controlled signal
Tt :Delay on threshold crossing
12
A212
11
R
14
11
14
Warning
1. This product shall be installed , operated and maintained by professional personnel.
2 . Whether or not the product functions normally , user shall not dismantle or repair the said product without permission, and we shall not assume any responsibility for the accident as a result thereof.
3 . Please refer to the wiring diagram in Operation Instructions when arranging wires.
4 . Never place power input line in the same conduit with other wires with heavy current. Please use shielded wire if necessary so as not to bring about interference that may influence the normal operation of relay.
5 . Do not use this product in areas with dust , corrosive gases and with exposure to direct sunlight and rain.
6 . Never use this product in medium with explosion hazard and with gases that may corrode metals and destroy the insulation, and do not use this product in a space
with conductive dust.
7 . Please store and use this product at rated supply voltage and stated temperature , height above sea level and humidity .
8 . Failure to follow these instructions can result in death, serious injury, or equipment damage.
9. The warranty period of this product shall be 18 months under normal use .
-2-