Download Bedienungsanleitung Operating Instructions
Transcript
Problem “Water level too low” Potential cause Solution Not enough water in the bath. >> Refill the water until Otherwise: >> Call Customer Service. “Flow rate heating” 14. Maintenance Backflow preventer with dirt filter With the option “Integrated Filling” a backflow preventer with dirt filter is integrated into the pool. >> Have the dirt filter and backflow preventer checked regularly by a qualified plumber as described in their respective operating instructions. >> Call Customer Service. “Difference water sensors” “Timeout Filling” the water level is about 50 mm above the uppermost jet. see page >> Check water connection. Pool has not reached maximum fill level. Pipe pressure too low, pipe not supplying enough water. Otherwise: >> Call Customer Service. Heating deactivated because of insufficient water flow rate. >> Check the suction outlet, Otherwise: >> Call Customer Service. inlet jet, coarse filter and fine filter of the hygiene and temperature circuit for objects that may cause clogging. >> Call Customer Service. “Connection defective” Residual-current circuit-breaker >> Check the residual-current circuit-breaker regularly as described in its operating instructions. O3 Generator The basic disinfection of the pool is performed by an O3 generator, a disinfection unit that generates ozone using an ultra-violet (UV) lamp. The duty life of the UV lamp is limited to 20,000 hours and 1,000 hours before expiry of the duty life a message “Maintenance O3-generator” will be displayed on the operator’s panel. >> Arrange an appointment, at the most 2 months after the warning is first displayed, with our Customer Service, phone.+49 180 5332343. In normal operation this replacement has to be made every 6-7 years. You have entered the wrong PIN. >> Enter the correct PIN 15. Technical Data Forgot PIN? >> Enter PIN 2412. 15.1 Identification Plate “Maintenance O3generator” The maximum operating life of the O3 generator has expired. >> Arrange an appointment, “Function not present” Sound and integrated filling are optional modules. “Wrong PIN” 46 at the most two months after the warning is first displayed, with your local Customer Service. The identification plate is on the back page of the Operators Manual. This product conforms to all the appropriate EU guidelines. 15.2 Whirlpool Rated voltage Frequency Max. rated power •Heater element •Whirl system Protection class 220–240 V - (AC) 71xxx 00 8 xx00 71xxx 00 8 xx06 50 Hz, 60 Hz 3 KW 3 KW I 47