Download Bedienungsanleitung Operating Instructions

Transcript
Problem
“Water level too low”
Potential cause
Solution
Not enough water
in the bath.
>> Refill the water until
Otherwise:
>> Call Customer Service.
“Flow rate heating”
14. Maintenance
Backflow preventer with dirt filter
With the option “Integrated Filling” a backflow preventer with dirt filter is integrated
into the pool.
>> Have the dirt filter and backflow preventer checked regularly by a qualified
plumber as described in their respective operating instructions.
>> Call Customer Service.
“Difference water
sensors”
“Timeout Filling”
the water level is
about 50 mm above the
uppermost jet.
see
page
>> Check water connection.
Pool has not reached
maximum fill level.
Pipe pressure too low,
pipe not supplying enough
water.
Otherwise:
>> Call Customer Service.
Heating deactivated
because of insufficient
water flow rate.
>> Check the suction outlet,
Otherwise:
>> Call Customer Service.
inlet jet, coarse filter and
fine filter of the hygiene
and temperature circuit
for objects that may cause
clogging.
>> Call Customer Service.
“Connection defective”
Residual-current circuit-breaker
>> Check the residual-current circuit-breaker regularly as described in its operating
instructions.
O3 Generator
The basic disinfection of the pool is performed by an O3 generator, a disinfection unit
that generates ozone using an ultra-violet (UV) lamp. The duty life of the UV lamp
is limited to 20,000 hours and 1,000 hours before expiry of the duty life a message
“Maintenance O3-generator” will be displayed on the operator’s panel.
>> Arrange an appointment, at the most 2 months after the warning is first displayed,
with our Customer Service, phone.+49 180 5332343.
In normal operation this replacement has to be made every 6-7 years.
You have entered the
wrong PIN.
>> Enter the correct PIN
15. Technical Data
Forgot PIN?
>> Enter PIN 2412.
15.1 Identification Plate
“Maintenance O3generator”
The maximum operating
life of the O3 generator
has expired.
>> Arrange an appointment,
“Function not present”
Sound and integrated
filling are optional
modules.
“Wrong PIN”
46
at the most two months
after the warning is first
displayed, with your local
Customer Service.
The identification plate is on the back page of the Operators Manual. This product
conforms to all the appropriate EU guidelines.
15.2 Whirlpool
Rated voltage
Frequency Max. rated power
•Heater element
•Whirl system
Protection class
220–240 V - (AC)
71xxx 00 8 xx00
71xxx 00 8 xx06
50 Hz,
60 Hz
3 KW
3 KW
I
47