Download Service Manual - daikin tech.co. uk
Transcript
SiBE041029EB Drawing of Inverter Main Functions The following drawing shows a schematic view of the inverter principle: Refrigerant circulation rate (high) AC power Amount of heat exchanged air (small) DC power high speed Amount of heat exchanged air (large) high f low f low speed 50 Hz freq= constant 60 Hz freq=variable Amount of heat exchanged air (large) Amount of heat exchanged air (small) capacity= variable Refrigerant circulation rate (low) Inverter Features (R2812) The inverter provides the following features: The regulating capacity can be changed according to the changes in the outdoor Frequency Limits temperature and cooling / heating load. Quick heating and quick cooling The rotation speed of the compressor is increased when starting the heating (or cooling). This enables to reach the set temperature quickly. Even during extreme cold weather, high capacity is achieved. It is maintained even when the outdoor temperature is 2°C. Comfortable air conditioning A fine adjustment is integrated to keep the room temperature constant. Energy saving heating and cooling Once the set temperature is reached, the energy saving operation enables to maintain the room temperature at low power. The following functions regulate the minimum and maximum frequency: Frequency Low High Forced Cooling Operation Function and Control Functions Four way valve operation compensation. Refer to page 34. Compressor protection function. Refer to page 34. Discharge pipe temperature control. Refer to page 35. Input current control. Refer to page 36. Freeze-up protection control. Refer to page 37. Heating peak-cut control. Refer to page 37. Defrost control. Refer to page 39. Refer to page 104 for detail. 18