80
DATA PROCESSING AND NETWORK INTERFACING
control and monitoring. A third computer could be used by a quality control
monitoring group assigned to make needed chromatographic adjustments.
Finally, a fourth computer could be assigned to forms generation.
8.3 NETWORKING CONNECTION
At first, to make all this work, data would be moved from computer to
computer on diskette by “sneaker net.” Once local area networks (LANs)
were set up, the data file could be moved electronically point to point from
computer to computer. Eventually, with wide area networks (WANs) in place,
files such as reports and data sets could be moved from location to location, to
computers of different types, even to facilities in other states.
Care had to be taken that data was not wiped from the original computer
until it was certain that the next processing computer had received a copy.
Archival storage of the original data set was important when data might have
to be defended in court or before a government regulating organization.
Large, sequentially stored tape data sets were built to provide this legacy
archive. These archives may never be needed, but they must be accessible
when the data is required. This has lead to one of the potential problems facing
contracting analytical laboratories, which will be discussed next.
8.4 REPLACEMENT CONTROL AND PROCESSING SYSTEMS
Over time, a problem began to arise with the GC/MS system. The mass
spectrometer has changed little in the last 15 years, except to become smaller
and more compact. Compared to the state-of-the-art computers, the heart of
the original processing and control system rapidly became outdated. Hard
disks were too small to meet the rising sample demand, the computers were
too slow, and the programming was too difficult to use. In addition, the
operating system and proprietary data storage system were incompatible with
systems from other manufacturers. If a laboratory bought systems from more
than one vendor, different systems from the same vendor over time, or
acquired other laboratories with different systems, incompatibilities resulted.
Only certain operators could run certain machine. If the operators were sick,
the machines were sick. If the operator went on maternity leave, the machine
was down or someone else had to be trained to run it.
Replacement computers with newer operating systems and better, faster
software appeared to be the answer, but replacing a computer was like doing a
heart transplant. The new software must be able to control the mass