Download GC/MS : A Practical User's Guide
Transcript
80 DATA PROCESSING AND NETWORK INTERFACING control and monitoring. A third computer could be used by a quality control monitoring group assigned to make needed chromatographic adjustments. Finally, a fourth computer could be assigned to forms generation. 8.3 NETWORKING CONNECTION At first, to make all this work, data would be moved from computer to computer on diskette by “sneaker net.” Once local area networks (LANs) were set up, the data file could be moved electronically point to point from computer to computer. Eventually, with wide area networks (WANs) in place, files such as reports and data sets could be moved from location to location, to computers of different types, even to facilities in other states. Care had to be taken that data was not wiped from the original computer until it was certain that the next processing computer had received a copy. Archival storage of the original data set was important when data might have to be defended in court or before a government regulating organization. Large, sequentially stored tape data sets were built to provide this legacy archive. These archives may never be needed, but they must be accessible when the data is required. This has lead to one of the potential problems facing contracting analytical laboratories, which will be discussed next. 8.4 REPLACEMENT CONTROL AND PROCESSING SYSTEMS Over time, a problem began to arise with the GC/MS system. The mass spectrometer has changed little in the last 15 years, except to become smaller and more compact. Compared to the state-of-the-art computers, the heart of the original processing and control system rapidly became outdated. Hard disks were too small to meet the rising sample demand, the computers were too slow, and the programming was too difficult to use. In addition, the operating system and proprietary data storage system were incompatible with systems from other manufacturers. If a laboratory bought systems from more than one vendor, different systems from the same vendor over time, or acquired other laboratories with different systems, incompatibilities resulted. Only certain operators could run certain machine. If the operators were sick, the machines were sick. If the operator went on maternity leave, the machine was down or someone else had to be trained to run it. Replacement computers with newer operating systems and better, faster software appeared to be the answer, but replacing a computer was like doing a heart transplant. The new software must be able to control the mass