DIGITAL CONTROL INCORPORATED
2. From the Main menu, select the HAG menu option. The HAG menu displays with the
Enable HAG option highlighted for selection and the current or default (12 in. or 0.30
m) HAG setting shown in the description line at the bottom of the screen. If the HAG
had previously been enabled, the disable option would show automatically highlighted
for selection.
Set HAG
Disable HAG
Exit
Enable HAG
Description of
highlighted selection
with current HAG setting
in inches or meters
HAG Menu
3. To change the HAG value shown at the bottom of the screen, select Set HAG and
enter a new value (for help with using the onscreen keypad, see Using the Keypad on
page 22). After you press the execute button on that screen, the receiver beeps four
times and returns to the Main menu. Select HAG again from the Main menu, then
select Enable HAG to use your new HAG setting. Skip the following step.
4. If the HAG value shown at the bottom of the screen is acceptable, select Enable HAG.
The receiver beeps four times as it enables HAG and returns to the Main menu.
Depth readings (holding the trigger) must now be taken with the receiver held at this height.
As noted above, to prevent incorrect readings, HAG must be manually turned on each time
the F5 is turned on.
58
DigiTrak F5 Operator’s Manual