3. System Configuration and Wiring 3. System Configuration and Wiring Wiring to the connector, X4 Wiring to the connector, X5 : Twisted pair) Negative direction torque limit input (0 to ±10V) Select with Pr3.17. Provide a power supply for the external scale on your part or use the following power output (250mA or less). Application Torque monitor output 42 A, B, Z phase Endoder signal input IM SP 43 I/F of external scale signals 1kΩ 1kΩ 20kΩ 20kΩ 14kΩ Velocity monitor output ( Power supply output The functions of the following pin can be changed using parameters. Input: 8, 9, 26, 27, 28, 29, 30, 31, 32, 33 Output: 10-11, 12, 34-35, 36-37, 38-39, 40 FG 50 41 COM- ZSP Zero speed detection output 12 TLC Torque in-limit output External brake release output At-speed output VDC 12 to 24V Remarks 40 11 BRKOFF+ 10 BRKOFF- 39 AT-SPEED+ 38 AT-SPEED- ALM- 36 ALM+ Servo-Alarm output 37 35 S-RDY+ 34 S-RDY- Servo-Ready output 8 31 A-CLR 9 POT Alarm clear input Positive direction over-travel inhibition input Negative direction over-travel inhibition input Control mode switching input Speed zero clamp input NOT 28 DIV1 26 ZEROSPD 32 C-MODE 29 SRV-ON 27 GAIN Servo-ON input Gain switching input CL INH 30 33 7 COM+ 4.7kΩ X4 – – + 10kΩ 16 17 GND CCWTL/TRQR P-ATL/TRQR 16 17 GND 10kΩ + 20kΩ 20kΩ 14kΩ N-ATL 18 Wiring example when control mode Pr0.01=5 or Pr3.17=1 Torque command input or velocity limit input (0 to ±10V) 15 14 GND SPR/TRQR/SPL 47kΩ – + 20kΩ Divider 20kΩ 47kΩ 47kΩ 47kΩ CZ GND 25 19 Z-phase output (open collector) Z-phase output 24 OZ- OZ+ 23 B-phase output 49 48 OB+ OB- 22 OA- OA+ Connect on to External Scale X1 to X7 are used for the secondary circuit. To connect these terminals to the primary power supply (particularly, the 24 VDC power supply for brake), insulation is required. Do not connect these terminals to the same power supply. − B28 − Frame ground Symbol Connector Pin No. Contents EX5V 1 Supply the power of external scale or A, B, Z phase encoder. EX0V 2 Connected to ground of control circuit. EXPS 3 /EXPS 4 EXA 5 /EXA 6 EXB 7 /EXB 8 EXZ 9 /EXZ 10 FG Shell Serial signal The transmission / reception method. Parallel signal reception Correspondence speed : 4Mpps (after quadruple) Connected with ground terminal in the servo driver. Connector (plug): MUF-PK10K-X (by J.S.T. Mfg. Co., Ltd.) • Caution 1) The manufacturers applicable external scales for this product are as follows. • Mitutoyo Corp. • Magnescale Co., Ltd. For the details of the external scale product, contact each company. 2) Recommended external scale ratio is 1/40 ≤ External scale ratio ≤ 160 If you set up the external scale ratio to smaller value than 50/position loop gain (Pr1.00 and Pr.1.05), you may not be able to control per 1 pulse unit. Setup of larger scale ratio may result in larger noise. Remarks X1 to X7 are used for the secondary circuit. To connect these terminals to the primary power supply (particularly, the 24 VDC power supply for brake), insulation is required. Do not connect these terminals to the same power supply. − B29 − English 21 A-phase output Wiring Example of Torque Control Mode