Download User Manual
Transcript
UIM241XX Miniature Integrated Stepper Motor Controller 4. BDRη Set RS232 Baud Rate Format: BDRη; Description: Set RS232 Baud Rate η = 9600, 19200, 38400, 56000, 100000, 115200, 250000; Other value of baud rate is also available, but it must be integral multiple of 100. ACK: AA [Reserved] BD FF Comment: [Reserved] >> Factory use; BD >> Message ID of instruction BDR. Note: The new baud rate will be stored in the controller’s non-volatile memory (EEPROM). New baud rate will take effect after the controller is restarted. UI Robot Technology Co. Ltd. M4120130828EN Page 51