Download bdiGDB User Manual

Transcript
bdiGDB for BDI3000 (PowerPC MPC85xx/P10xx/P2020)
User Manual
21
3.2 Configuration File
The configuration file is automatically read by the BDI after every power on.
The syntax of this file is as follows:
; comment
[part name]
identifier parameter1
identifier parameter1
.....
[part name]
identifier parameter1
identifier parameter1
.....
etc.
parameter2 ..... parameterN
parameter2 ..... parameterN
; comment
parameter2 ..... parameterN
parameter2 ..... parameterN
Numeric parameters can be entered as decimal (e.g. 700) or as hexadecimal (0x80000).
Note about how to enter 64bit values:
The syntax for 64 bit parameters is :
Hex values may also be entered as:
[<high word>_]<low word>
0xnnnnnnnnnnnnnnnn
The "high word" (optional) and "low word" can be entered as decimal or hexadecimal. They are handled as two separate values concatenated with an underscore.
Examples:
0x0123456789abcdef
0x01234567_0x89abcdef
1_0
256
3_0x1234
0x80000000_0
=>>
=>>
=>>
=>>
=>>
=>>
0x0123456789abcdef
0x0123456789abcdef
0x0000000100000000
0x0000000000000100
0x0000000300001234
0x8000000000000000
© Copyright 1997-2014 by ABATRON AG Switzerland
V 1.08