Download ENG
Transcript
ENG type of heads system flow-rate lb/h A B C D line length E 32 feet 80 feet 160 feet air water air water air water air water ID mm ID mm ID mm ID mm ID mm ID mm ID mm ID mm 65 11 8 6 4 3 5/8 1/2 3/4 5/8 3/4 5/8 1 3/4 130 22 15 11 9 6 3/4 1/2 1 5/8 1 1/4 5/8 1 1/4 3/4 260 44 30 22 18 12 1 1/4 1/2 1 1/4 5/8 1 3/8 5/8 1 1/2 3/4 500 85 58 43 34 23 1 3/8 1/2 1 1/2 5/8 1 3/4 5/8 2 1/4 3/4 Note: If the air line is more than 50 metres log, size the line so that the pressure drop does not exceed 0.2 bar. Try to limit the number of connections in the air and water lines to the minimum possible. The use of elbow or “T” connectors and reducers/adapters will increase the pressure drop in the lines. The diameters shown in the tables have been selected considering the use of a pair of connectors in each line, if the number of connectors doubles choose the next largest diameter. maintenance distribution cabinet no. heads installed per type 16 feet “MCmultizone” +030221981 - rel. 2.1 - 21.05.2009 38