Download Operating Instructions Type 3005

Transcript
Type 3005
Installation
Adjusting cams for limit switch contacts
Cam
Cam
Key
Key
Adjustment travel
Fig. 13:
Adjustment travel
Adjusting limit switch clockwise
Fig. 14:
Adjusting limit switch anti-clockwise
Procedure:
→→Adjust the two upper cams with a suitable key (see Fig. 13:Adjusting limit switch clockwise and Fig. 14:Adjusting
limit switch anti-clockwise).
→→On completion of the adjustment work, re-attach the hood 3, the position indicator, the seal and the glass
hood 1.
The rotary actuator is supplied ex works with the following settings:
The limit switch CLOSED (FCF) is actuated by the cam (closed position).
The limit switch OPEN (FCO) is preset to a rotation angle of 90°.
Feedback
4-6
2
3
7
FC2
Power supply and control
1
5
FC1
T/E
D
C
A
C
FCF
D
B
FC0
Motor
=
Fig. 15:
Internal wiring of drive
25