No. Accessory part Qty. No. Adjustable Feet Qty. Drain Elbow 1 2 Accessory part 4 3 Reducing Adapter 1 4 1 Packing No. Part Qty. i 2-way Valve Kit 1 ii Room Thermostat 1 Electromotoric Actuator 2-port Valve Analog Type Programmable Type Specifications Maker AC230V -- Siemens Siemens AC230V Siemens It is recommended to purchase the field supply accessories from the specific maker whom listed in above table. 1 Dimension Diagram Main Components Diagram Tube Position Diagram 598 400 Model SFA21/18 VVI46/25 RAA20 REV200 cdef 717 b 1 k a f e h d c b 0 9 8 a g i l 2 j 3 g 7 475 380 300 230 159 102 Anode Bar 1800 ENGLISH Field Supply Accessories Attached accessories 4 h m 5-1 5-2 FRONT VIEW 478 SIDE VIEW 674 60 612 427 i 29 70 60 679 670 562 5 145 30 19 6 Adjustable Feet 1 position 36 Tube Connector Function BOTTOM VIEW h i Drain Water Hole b c d e f g Model Capacity (L) ADC0309* 1 Connector Size Water Inlet (From Space Heating/Cooling) Water Outlet (To Space Heating/Cooling) Cold Water Inlet (Domestic Hot Water Tank) Hot Water Outlet (Domestic Hot Water Tank) Refrigerant Gas Refrigerant Liquid Domestic Hot Water Tank Discharge Pressure Relief Valve Drainage a 185 R 1¼" R 1¼" R ¾" R ¾" 7/18-14UNF 7/16-20UNF Rc 1/2" ----- Weight (kg) Empty Full 135 320 1 2 3 4 5-1 5-2 6 7 8 9 0 a b c d e f g h i j k l m Control Panel Water Pump Control Board Cover PCB, Printed Circuit Board Single Phase RCCB/ELCB (Main Power) Single Phase RCCB/ELCB (Backup Heater) Water Filter Set Anode Bar (Not Visible) Heater Cover Heater Assembly 3-Way Valve Overload Protector (Not Visible) Expansion Vessel (Not Visible) Air Purge Valve Pressure Relief Valve Flow Switch Water Pressure Gauge Top Front Plate Bottom Front Plate Top Plate Right Plate Left Plate Rear Plate Tank Sensor (Not Visible) SELECT THE BEST LOCATION Install the Tank Unit in indoors with frost free weather proof location only. Must install on a flat horizontal and solid hard surface. A place where Tank Unit’s operation noise will not cause discomfort to the user. A place where Tank Unit is far from door way. There should not be any heat source or steam near the Tank Unit. A place where accessible for maintenance. A place where air circulation in the room is good. Ensure to keep minimum distance of spaces as illustrated below from wall, ceiling, or other obstacles. A place where flammable gas leaking might not occur. A place where drainage can be easily done (e.g. Utility room). Secure the Tank Unit to prevent it being knocked over accidentally or during earthquakes. Transport and Handling Required space for installation • • • • (Unit : mm) Min. 300 M 10 in. 0 . in M 00 1 in. M 00 7 M 10 in. 0 • Be careful during transportating the unit so that it is not damaged by impact. Only remove the packaging material once it has reached it is desired installation location. It may need three or more people to carry out the installation work. The weight of Tank Unit might cause injury if carried by one person. The Tank Unit can be transported either in vertical or horizontal. - If it transported in horizontal, make sure Front of packaging material (printed with “FRONT”) must facing upwards. - If it transported in vertical, use the hand holes on sides, slide and move to the desired location. Fix the Adjustable Feet 1, if the Tank unit installed on a uneven surface. Hold Hold arrow section to slide and move Hold 3