Download CO N TRO LLER ATR142 Manuale Installatore User Manual
Transcript
- REG O LATO RE - CO N TRO LLER ATR1 4 2 M a nua le I nsta lla tore Use r M a nua l Summary 1 2 3 Introduction...........................................................................................4 Model Identification...............................................................................4 Technical Data .....................................................................................5 3.1 3.2 3.3 4 5 Dimensions and Installation..................................................................6 Electrical wirings...................................................................................7 5.1 6 Wiring diagram ........................................................................................... 7 Display and Key Functions .................................................................10 6.1 6.2 6.3 7 Numeric Indicators (Display) .................................................................... 11 Meaning of Status Lights (Led) ................................................................ 11 Keys.......................................................................................................... 11 Controller Functions ...........................................................................12 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.12 8 Modifying Main Setpoint and Alarm Setpoint Values ............................... 12 Auto-Tune ................................................................................................. 12 Manual Tuning.......................................................................................... 12 Automatic Tuning...................................................................................... 13 Soft Start................................................................................................... 13 Automatic/Manual Regulation for % Output Control ................................ 13 Pre-Programmed Cycle ............................................................................ 14 Memory Card (optional)............................................................................ 15 Loading default values.............................................................................. 16 LATCH ON Functions............................................................................... 16 Digital Input Functions .............................................................................. 18 Dual Action Heating-Cooling .................................................................... 19 Serial Communication ........................................................................21 8.1 8.2 9 Slave......................................................................................................... 21 Master....................................................................................................... 26 Configuration ......................................................................................28 9.1 10 11 12 13 2 General Features........................................................................................ 5 Hardware Features..................................................................................... 5 Software Features ...................................................................................... 6 Modify Configuration Parameter............................................................... 28 Table of Configuration Parameters .....................................................29 Alarm Intervention Modes...................................................................43 Table of Anomaly Signals ...................................................................48 Summary of Configuration parameters ...............................................49 Sommario 14 Introduzione........................................................................................52 15 Identificazione del modello .................................................................52 16 Dati tecnici..........................................................................................53 16.1 16.2 16.3 Caratteristiche generali............................................................................. 53 Caratteristiche hardware .......................................................................... 53 Caratteristiche software............................................................................ 54 17 Dimensioni e installazione ..................................................................54 18 Collegamenti elettrici ..........................................................................55 18.1 Schema di collegamento .......................................................................... 55 19 Funzione dei visualizzatori e tasti .......................................................58 19.1 19.2 19.3 Indicatori numerici (display)...................................................................... 59 Significato delle spie di stato (led) ............................................................ 59 Tasti .......................................................................................................... 59 20 Funzioni del regolatore .......................................................................60 20.1 20.2 20.3 20.4 20.5 20.6 20.7 20.8 20.9 20.10 20.11 20.12 Modifica valore setpoint principale e setpoint di allarme.......................... 60 Auto-tune .................................................................................................. 60 Lancio del Tuning Manuale ...................................................................... 60 Tuning Automatico.................................................................................... 61 Soft Start................................................................................................... 61 Regolazione automatico / manuale per controllo % uscita ...................... 61 Ciclo pre-programmato............................................................................. 62 Memory Card (opzionale) ......................................................................... 63 Caricamento valori di default .................................................................... 64 Funzione LATCH ON................................................................................ 64 Funzioni da Ingresso digitale.................................................................... 66 Funzionamento in doppia azione (caldo-freddo) ...................................... 67 21 Comunicazione Seriale.......................................................................69 21.1 21.2 Slave......................................................................................................... 69 Master....................................................................................................... 74 22 Configurazione ...................................................................................76 22.1 23 24 25 26 Modifica parametro di configurazione ...................................................... 76 Tabella parametri di configurazione ....................................................77 Modi d’intervento allarme....................................................................91 Tabella segnalazioni anomalie............................................................96 Promemoria configurazione................................................................97 3 1 Introduction Thank you for choosing a Pixsys controller. With the ATR142 model Pixsys makes available in a single device all the resources relevant to sensor input and actuators command, in addition to the extended power range 24…230 Vac/Vdc. With 17 sensors to select and outputs configurable as relay or SSR command, the user or retailer can reduce warehouse stock by rationalising investment and device availability. The series is completed with models equipped with serial communication RS485 Modbus. The configuration is further simplified by the Memory cards which are equipped with internal battery and therefore don’t require cabling to power the controller. 2 Model Identification The range of ATR142 controllers comes in two versions. Refer to the table below to easily select your preferred model. Models available, with power 24…230 Vac/Vdc +/-15% 50/60Hz – 4,6VA ATR142-ABC 2 relays (8A+5A) + 1 SSR ATR142-ABC-T 1 relays 8A + 1 Ssr + RS485 4 3 Technical Data 3.1 General Features Displays 4 0.40 inch displays + 4 0.30 displays Operating 0-45°C, humidity 35..95uR% temperature Sealing IP65 front panel (with gasket) IP30 casing and IP20 terminals Material Polycarbonate UL94V0 self-extinguishing Weight 100 g 3.2 Hardware Features Analogue AN1 input Configurable via software Input Thermocouple type K, S, R, J Automatic compensation of cold junction from 0°C to 50°C. Thermoresistance: PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (β 3435K) Linear: 0-10V, 0-20 or 4-20mA, 0-40mV Potentiometers: 6KΩ, 150KΩ, Relay 2 relays (ATR142-ABC) output 1 relay (ATR142-ABC-T) Configurable as command and/or alarm output SSR output 1 SSR Configurable as command output and/or alarm output. Supply Power supply 24..230 Vac/Vdc +/-15% 50/60Hz Tolerance (25°C) +/-0.2 % ± 1 digit for thermocouple input, thermo resistance and V/mA. Cold junction accuracy 0.1°C/°C Contacts: Q1: 8A-250V~ for resistive loads Q2: 5A-250V~ for resistive loads 12Vdc/30mA Power consumption 4.6VA 5 3.3 Software Features Regulation algorithms ON-OFF with hysteresis. P, PI, PID, PD with proportional time Proportional band Integral time Derivative time Controller functions 0...9999°C or °F 0,0...999,9 sec (0 excluded) 0,0...999,9 sec (0 excluded) Manual or automatic Tuning, configurable alarms, protection of command and alarm setpoints, activation of functions via digital input, preset cycle with Start/Stop. 4 Dimensions and Installation Dima di foratura 28.5 x 70.5 mm Frontal panel cut-out Spessore suggerito 2÷8 mm Suggested thickness Guarnizione per 32x74 Cod. 1620.00.082 (optional) Gasket for 32x74 Memory Card (optional) Cod. MEMORY C241 MEMORY C.121 42mm inserimento Memory Card 42mm insert Memory Card Memory Card (optional) with battery Cod. MEMORY C243 U1 C1 35 mm 6 3 77 mm 6 1 NC 2 1 1 7 53 mm 5 Electrical wirings Although this controller was designed to resist noises in industrial environments, pease notice following safety guidelines: • Separate the feeder line • Avoid placing near from the power lines. units with remote control switches, electromagnetic contactors, high powered motors and in all instances use specific filters. • Avoid placing near power units, particularly if phase controlled. 5.1 Wiring diagram The connections are reported below for the three models available. PIXSYS ATR142-ABC 2 wire 4/20mA Power 8A 230V Resistive 1/2HP 5A 230V Resistive 1/8HP Q1 Q2 PT/NI100/1K PTC/NTC 1 1 2 3 4 5 6 7 8 9 10 11 12 Memory PIXSYS ATR142-ABC-T 2 wire 4/20mA Power 8A 230V Resistive 1/2HP PT/NI100/1K Q1 PTC/NTC RS485 1 1 2 3 4 5 6 7 8 9 10 11 12 Memory 7 Power 1 2 2 4. ..23 0 V A C /D C Switching power supply with extended range 24…230 Vac/dc ±15% 50/60Hz – 5,5VA. AN1 Analogue Input Shield/Schermo - 12 + Tc 11 Shield/Schermo 11 B PT /NI100 10 A 12 C For thermocouples K, S, R, J. • Comply with polarity • For possible extensions, use a compensated wire and terminals suitable for the thermocouples used (compensated) • When shielded cable is used, it should be grounded at one side only For thermoresistances PT100, NI100 • For the three-wire connection use wires with the same section • For the two-wire connection short-circuit terminals 10 and 12 • When shielded cable is used, it should be grounded at one side only to avoid ground loop currents RED WHITE RED Shield/Schermo 11 PTC/NTC 10 9 V/ I 12 + 11 +VDC 10 8 Shield/Schermo 10 11 12 For thermoresistances NTC, PTC, PT500, PT1000 e potentiometers • When shielded cable is used, it should be grounded at one side only to avoid ground loop currents For linear signals V/mA • Comply with polarity • When shielded cable is used, it should be grounded at one side only to avoid ground loop currents Examples of Connection for linear input 12 For signals 0….10V 0...10V 11 Comply with polarity 12 0/4...20mA 11 9 PRESSURE TRANSMITTER For signals 0/4….20mA with three-wire sensor Comply with polarity C=Sensor output B=Sensor ground A=Sensor power 12 For signals 0/4..20mA with external power of sensor 0/4...20mA 11 E xternal supply PRESSURE TRANSMITTER Comply with polarity C=Sensor output B=Sensor ground 12 For signals 0/4...20mA with two-wire sensor 4...20mA 9 PRESSURE TRANSMITTER Comply with polarity C=Sensor output A=Sensor power supply Serial input + 7 R S4 85 - 6 Shield/Schermo RS485 Modbus RTU communication 11 Do not use LT (line termination) resistors For networks with more than five instruments supply in low voltage 9 Relay Q1 Output 7 Capacity: Q1 • n.o. contact : 8A/250V~ - ½HP • n.c. contact : 8A/250V~ for resistive loads Q2 • 5A/250V~ for resistive loads Q2 6 5 4 Q1 3 SSR output 8 SSR command output 12V/30mA SSR 9 Digital Input on ATR243-20ABC 10 Digital input using parameter . The use of digital input in this version is possible only with TC sensors, 0…10V, 0/4…20mA and 0…40mV 11 6 Display and Key Functions 1 9 12 1 2 M T 10 3 10 4 5 3 R 6 11 7 8 2 6.1 Numeric Indicators (Display) Normally displays the process. During the configuration phase, it displays the parameter 1 being inserted. Normally displays the setpoint. During the 2 configuration phase, it displays the parameter value being inserted. 6.2 Meaning of Status Lights (Led) 3 ON when the output command is on. For motorised valve command, led in on when valve is opening and blink when closing. 4 ON when alarm 1 is on. 5 ON when alarm 2 is on. 6 ON when the “Manual” function is on. ON when the controller is running an “Autotune” cycle. 7 8 ON when the controller communicates via serial port. 6.3 Keys 9 • Allows to increase the main setpoint. • During the configuration phase, allows to slide through parameters. Together with the SET key it modifies them. SET key it allows to increase the alarm • Pressed after the setpoint. • Allows to decrease the main setpoint. • During the configuration phase, allows to slide through 10 parameters. Together with the SET key it modifies them. SET 11 SET 12 FNC • Pressed after the key it allows to decrease the alarm setpoint. • Allows to display the alarm setpoint and runs the autotuning function. • Allows to vary the configuration parameters. • Allows to display the alarm setpoint and runs the autotuning function. • Allows to vary the configuration parameters. 11 7 Controller Functions 7.1 Modifying Main Setpoint and Alarm Setpoint Values The setpoint value can be changed from the keyboard as follows: Press Effect 1 Value on display 2 changes or 2 Operation Increases or decreases the main setpoint Visualize alarm setpoint on display 1 Value on display 2 Increases or decreases the changes alarm set point value SET 3 o 7.2 Auto-Tune The Tuning procedure calculates the controller parameters and can be manual or automatic according to selection on parameter 46 . 7.3 Manual Tuning The manual procedure allows the user greater flexibility to decide when to update PID algorithm work parameters. The procedure can be activated in two ways. • By running Tuning from keyboard: Press the FNC key until display 1 shows the writing display 2 showing , press , display 2 shows The led switches on and the procedure begins. • By running Tuning from digital input: Select on parameter 50 . On first activation of digital input (commutation on front panel) the led switches on and on second activation switches off. 12 with . 7.4 Automatic Tuning Automatic tuning activates when the controller is switched on or when the setpoint is modified to a value over 35%. To avoid an overshoot, the treshold where the controller calculates the new PID parameters is determined by the setpoint value minus the ). “Set Deviation Tune” ( see Parameter 47 To exit Tuning and leave the PID values unchanged, just press the FNC key until display 1 shows the writing , press , display 2 shows showing The led switches off and the procedure finishes. with the display . 7.5 Soft Start To reach the setpoint the controller can follow a gradient expressed in units (e.g. degree/hour). Set the increase value in parameter 51 with the desired units/hour; only on subsequent activation the controller uses the soft start function. Automatic/manual tuning cannot be enabled if the Soft start is active. 7.6 Automatic/Manual Regulation for % Output Control This function allows you to select automatic functioning or manual command of the output percentage. With parameter 49 • The first selection the writing , you can select two methods. allows you to enable the FNC on display 1, while display two shows key with . Press the key to show ; it is now possible, during the process display, to change the output percentage using the keys and . To return to automatic mode, using the same procedure, select on display 2: the led switches off and functioning returns to automatic mode. 13 • • • The second selection enables the same functioning, but with two important variants: If there is a temporary lack of voltage or after switch-off, the manual functioning will be maintained as well as the previously set output percentage value. If the sensor breaks during automatic functioning, the controller moves to manual mode while maintaining the output percentage command unchanged as generated by the PID immediately before breakage. 7.7 Pre-Programmed Cycle The pre-programmed cycle function activates by setting in parameter 48 . The controller reaches setpoint1 basing on the gradient set in parameter 51 , then it reaches maximum power up to setpoint2. When the process reaches maximum power, this setpoint is maintained for the time set in parameter 52 . On expiry, process will reach ambient temperature according to gradient entered on parameter 64 will be desabled and display will visualize , then command output . The cycle starts at each activation of the controller, or via digital input if it is enabled for this type of functioning (see parameter 50 14 ). 7.8 Memory Card (optional) Parameters and setpoint values can be duplicated from one controller to another using the Memory card. There are two methods: • With the controller connected to the power supply Insert the memory card when the controller is off. On activation display 1 shows and display 2 shows (Only if the correct values are saved in the memory card). By pressing the FNC key display 2 shows , then confirm using the key. The controller loads the new data and starts again. • With the controller not connected to power supply. The memory card is equipped with an internal battery with an autonomy of about 1000 uses. Insert the memory card and press the programming buttons. When writing the parameters, the led turns red and on completing the procedure it changes to green. It is possible to repeat the procedure without any particular attention. Updating Memory Card To update the memory card values, follow the procedure described in the first method, setting display 2 to so as not to load the 2 parameters on controller . Enter configuration and change at least one parameter. Exit configuration. Changes are saved automatically. 2 If on activation the controller does not display it means no data have been saved on the memory card, but it is possible to update values. 15 7.9 Loading default values This procedure makes it possible to restore factory settings of the instrument. Premere 1 FNC for 3 seconds. 2 or 3 Effetto Display 1 shows with the 1st digit flashing, while display 2 shows Change the flashing digit and move to the next SET to confirm Eseguire Enter password ET one using the S key. Instrument loads default settings Turn off and on the instrument 7.10 LATCH ON Functions For use with input (potentiometer 6KΩ) and (potentiometer 150KΩ ) and with linear input (0…10V, 0...40mV, 0/4…20mA), you can associate start value of the scale (parameter 6 ) to the minimum position of the sensor and value of the scale end (parameter 7 ) to the maximum position of the sensor (parameter 8 configured as ). It is also possible to fix the point in which the controller will display 0 (however keeping the scale range between and using the “virtual zero” option by setting or parameter 8 . If you set each activation of the tool; if you set fixed once tuned. 16 ) in the virtual zero will reset after the virtual zero remains To use the LATCH ON function configure as you wish the parameter .3 For the calibration procedure refer to the following table: Press 1 FNC Effect Operation Position the sensor on Exit parameters configuration. the minimum functioning Display 2 shows the writing value (associated with . 2 Set the value to minimum. The display shows ) Position the sensor on the maximum functioning position (associated with ) To exit the standard 3 Set the value to maximum. The display shows 4 NC procedure press F . For “virtual zero” settings position the sensor on the zero point. Set the virtual zero value. SET The display shows N.B.: for selection of To exit the procedure press FNC . the procedure in point 4 should be followed on each re-activation. MAX MIN 3 ZERO The tuning procedure starts by exiting the configuration after changing the parameter. 17 7.11 Digital Input Functions Digital input is programmable for several functions which are useful to simplify controller operability. Select the desired function on parameter . 50 • Hold function (enabled by setting or ) allows to lock the reading of sensors when the digital input is active (useful for wide ranging oscillation on less significant values). During the lock phase, display 2 flashes and shows • . Enables/disables the autotuning function from digital input if the parameter is set on . or . • Enable regulation with • Switch from automatic to manual functioning if or is set on . • Start of pre-programmed cycle (see paragraph 7.7) with . • Change setpoint function. This function is useful where there are 2 to 4 working thresholds required during system functioning without having to press the arrow keys. To enable the function use the parameter , by selecting the number of setpoints desired (no. thresholds switch). They can be switched during functioning by pressing the SET key. N.B.: The digital input functions are not available with sensors PT100, NI100, NTC, PTC, PT500, PT1000 e potentiometers. 18 7.12 Dual Action Heating-Cooling ATR142 is also suitable also for systems requiring a combined heatingcooling action. The command output must be configured as Heating PID ( = and with a greater than 0), and one of the alarms ( or ) must be configured as . The command output must be connected to the actuator responsible for heat, while the alarm will control cooling action. The parameters to configure for the Heating PID are: = Command output type (Heating) : Heating proportional band : Integral time of heating and cooling : Derivative time of heating and cooling : Heating time cycle The parameters to configure for the Cooling PID are the following (example: action associated to alarm1): = Alarm1 selection (cooling) : Proportional band multiplier : Overlapping/Dead band : Cooling time cycle The parameter (that ranges from 1.00 to 5.00) determines the proportional band of cooling basing on the formula: * Cooling proportional band = This gives a proportional band for cooling which will be the same as heating band if = 1.00, or 5 times greater if = 5.00. The integral time and derivative time are the same for both actions. The parameter determines the percentage overlapping between the two actions. For systems in which the heating output and cooling output must never be simultaneously active a dead band ( ≤ 0) must be configured, and vice versa you can configure an overlapping ( > 0). 19 The following figure shows an example of dual action PID (heating= 0 and cooling) with = 0. (COOL) * SPV <0 PV (HEAT) ACTIVE ACTIVE COMMAND OUTPUT (HEAT) ALARM OUTPUT (COOL) (COOL) * =0 SPV (HEAT) PV ACTIVE ACTIVE COMMAND OUTPUT (HEAT) ALARM OUTPUT (COOL) (COOL) * SPV >0 (HEAT) PV ACTIVE ACTIVE 20 COMMAND OUTPUT (HEAT) ALARM OUTPUT (COOL) The parameter cycle has the same meaning as the heating time . The parameter (cooling fluid) pre-selects the proportional and the cooling PID time cycle band multiplier on the type of cooling fluid: Cooling fluid type Air Oil Water Once selected, the parameter and 1.00 1.25 2.50 , the parameters basing 10 4 2 , can however be changed. 8 Serial Communication 8.1 Slave ATR142-ABC-T, equipped with RS485, can receive and broadcast data via serial communication using MODBUS RTU protocol. The is set as . device operates as slave if parameter 59 This function enables the control of multiple controllers connected to a supervisory system (SCADA). Each controller responds to a master query only if the query contains the same address as that in the parameter . The addresses permitted range from 1 to 254 and there must not be controllers with the same address on the same line. Address 255 can be used by the master to communicate with all the connected equipment (broadcast mode), while with 0 all the devices receive the command, but no response is expected. ATR142 can introduce a delay (in milliseconds) in the response to the master request. This delay must be set on parameter 58 Each parameter change is saved by the controller in the EEPROM memory (100000 writing cycles), while the setpoints are saved with a delay of ten seconds after the last change. 21 NB: Changes made to words that are different from those reported in the following table can lead to malfunction. Modbus RTU protocol features Baud-rate Can be selected on parameter 70 4800bit/sec 9600bit/sec 19200bit/sec 28800bit/sec 38400bit/sec 57600bit/sec Format 8, N, 1 (8bit, no parity, 1 stop) Supported WORD READING (max 20 word) (0x03, 0x04) functions SINGLE WORD WRITING (0x06) MULTIPLE WORDS WRITING (max 20 word) (0x10) The list below includes all the available addresses, where: RO = Read Only R/W = Read/Write WO = Write Only Modbus address 0 1 5 6 50 51 22 Description Device type Software version Slave Address Boot version Automatic addressing System code comparison Read Write RO RO R/W RO WO WO Reset value EEPROM EEPROM EEPROM EEPROM - 500 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 Loading default values: 9999 restore all values 9998 restore all values except for baudrate and slave address 9997 restore all values except for slave address 9996 restore all values except for baudrate Process (with tenths of degree for temperature sensors; digits for linear sensors) Setpoint1 Setpoint2 Setpoint3 Setpoint4 Alarm1 Alarm2 Setpoint gradient Outputs status (0=off, 1=on) Bit 0 = Q1 relay Bit 1 = Q2 relay Bit 2 = SSR Heating output percentage (0-10000) Cooling output percentage (0-10000) Alarms status (0=none, 1=active) Bit0 = Alarm 1 Bit1 = Alarm 2 Manual reset: write 0 to reset all the alarms. In reading (0=not resettable, 1=resettable): Bit0 = Alarm 1 Bit1 = Alarm 2 WO 0 RO ? R/W R/W R/W R/W R/W R/W RO RO EEPROM EEPROM EEPROM EEPROM EEPROM EEPROM EEPROM 0 RO 0 RO 0 RO 0 WO 0 23 1013 1014 1015 1016 1017 1018 1019 1100 1101 1102 1103 1104 1 Error flags Bit0 = Eeprom writing error Bit1 = Eeprom reading error Bit2 = Cold junction error Bit3 = Process error (sensor) Bit4 = Generic error Bit5 = Hardware error Bit6 = Master off-line Bit7 = Missing calibration data Cold junction temperature (tenths of degree) Start/Stop 0=controller in STOP 1=controller in START Lock conversion ON/OFF 0=Lock conversion off 1=Lock conversion on Tuning ON/OFF 0=Tuning off 1=Tuning on Automatic/manual selection 0=automatic 1=manual OFF LINE1 time (milliseconds) Process visualized (decimal as display) Setpoint1 visualized (decimal as display) Setpoint2 visualized (decimal as display) Setpoint3 visualized (decimal as display) Setpoint4 visualized (decimal as display) RO 0 RO ? R/W 0 R/W 0 R/W 0 R/W 0 R/W RO 0 ? R/W EEPROM R/W EEPROM R/W EEPROM R/W EEPROM If value is 0, the control is disabled. If different from 0, it is the max. time which can elapse between two pollings before the controller goes off-line. If it goes off-line, the controller returns to Stop mode, the control output is disabled but the alarms are active. 24 1105 1106 1107 1108 1109 1110 1111 2001 ... 2060 3000 3001 ….. 3008 3009 ….. 3016 3017 3018 Allarme1 visualized (decimal as display) Allarme2 visualized (decimal as display) Setpoint gradient (decimal as display) Heating output percentage (0-1000) Heating output percentage (0-100) Cooling output percentage (0-1000) Cooling output percentage (0-100) Parameter 1 ... Parameter 60 Disabling serial control of machine 2 First word display1 (ASCII) ….. Eighth word display1 (ASCII) First word display2 (ASCII) ….. Eighth word display2 (ASCII) Word LED Bit 0 = LED 1 Bit 1 = LED 2 Bit 2 = LED 3 Bit 3 = LED MAN Bit 4 = LED TUN Bit 5 = LED REM Word keys (write 1 to command keys) R/W EEPROM R/W EEPROM RO EEPROM RO RO RO RO R/W ... R/W WO R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 EEPROM ... EEPROM 0 0 0 0 0 0 0 0 R/W 0 Bit 0 = Bit 1 = Bit 2 = Bit 3 = 2 SET FNC By writing 1 on this word, the effects of the writing are cancelled on all the Modbus addresses from 3001 to 3022. Control therefore returns to the controller. 25 3019 3020 3021 Word serial outputs Bit 0 = Q1 relay Bit 1 = Q2 relay Bit 2 = SSR Word serial outputs state if off-line Bit 0 = Q1 relay Bit 1 = Q2 relay Bit 2 = SSR Word serial process R/W 0 R/W 0 R/W 0 8.2 Master The device works as master if the value selected on parameter 59 is other than . 8.2.1 Master Mode in retransmission Selecting this mode, the device will write the value to be retransmitted at the address selected on parameter 60 of the slave devices having same ID as the value selected on parameter 57 . Regarding retransmission of setpoint values, after writing the value on slaves, ATR142 starts reading the corresponding word, so that any modification of value on the slave will be automatically updated also on the Master. Two successive pollings will be delayed for the time selected on parameter 57 . The following table includes the options allowing the Master mode in retransmission and the relevant retransmitted value. Descrizione Write process value Write Process Write and read command setpoint value Read/Write Command Setpoint Write Output Percentage Write output percentage rated by P.I.D. function (Range 0-10000) Write and read alarm 1 setpoint value Read/Write Alarm 1 26 The read/written value might be rescaled according to the proportion described in the following table: Limiti valore ingresso Min. Max. Limiti valore riscalato Min. Max. Write Process Lower Limit Input Upper Limit Input Lower Limit Retransmission Upper Limit Retransmission Read/Write Command Setpoint Lower Limit Setpoint Upper Limit Setpoint Lower Limit Retransmission Upper Limit Retransmission Write Output Percentage 0 10000 Lower Limit Retransmission Upper Limit Retransmission Read/Write Alarm 1 Setpoint Lower Limit Setpoint Upper Limit Setpoint Lower Limit Retransmission Upper Limit Retransmission The input value (included between minimum and max limit) is linearly converted into the retransmitted value which is included between min and max output value. and have the Rescaling is not executed if parameters same value. 8.2.2 Master Mode Remote process To enable this function it is necessary to select on parameter 59 . In this mode the process value on ATR142 is a value read via serial communication. The ID of the slave must be same as value selected on parameter 57 and the word to read is selected on parameter 60 . Two successive pollings will be delayed for the time selected on parameter 57 The read value might be rescaled according to the proportion described in the following table: 27 Limits of read value Read Process Min. Max. Lower Limit Retransmission Upper Limit Retransmission Limits of rescaled value Min. Max. Lower Limit Input Upper Limit Input 9 Configuration 9.1 Modify Configuration Parameter For configuration parameters see paragraph 10. Press Effect FNC Display 1 shows with the 1st digit flashing, while display 2 shows 1 for 3 seconds. 2 or 3 . Change the flashing digit and move to the next one Operation Enter password ET SET to confirm using the S key. Display 1 shows the first parameter and display 2 shows the value. 4 or 5 SET + or 6 FNC 28 Slide up/down through parameters Increase or decrease the value displayed by pressing firstly SET and then an arrow key. End of configuration parameter change. The controller exits from programming. Enter the new data which will be saved on releasing the keys. To change another parameter return to point 4. 10 Table of Configuration Parameters The following table includes all parameters. Some of them will not be visible on the models which are not provided with relevant hardware features. no. 1 Display Parameter description Entering range Select command Command output type Output Default ATR142-ABC COMMAND ALARM 1 ALARM 2 Q2 Q1 SSR Q1(opens) Q2(closes) Q1 Q2 Q1 SSR SSR SSR Q2 - ATR142-ABC-T COMMAND ALARM 1 Q1 SSR Q1(opens) SSR(closes) SSR Q1 - 29 no Display 2 Sensor Parameter description Analog input configuration Entering range Tc-K (-260..1360°C) (Default) Tc-S (-40..1760°C) Tc-R (-40..1760°C) Tc-J (-200..1200°C) PT100 (-200..600°C) PT100 (-200..140°C) NI100 (-60…180°C) NTC10K (-40..125°C) PTC1K (-50…150°C) PT500 (-100..600°C) PT1000(-100..600°C) 0…10Volt 0…20mA 4…20mA 0…40mVolt Potenz.Max6KΩ F.S. Potenz.Max 150KΩF.S. 3 Decimal Point Select number of displayed decimal points Lower limit setpoint 4 Lower Limit Setpoint ∗ Default -999…+9999 digit∗ (degrees if temperature) Default: 0. The display of the decimal point depends on the setting of parameter and the parameter 30 . -999…+9999 digit* (degrees if temperature) Default: 1750. Setpoint Lower range limit -999…+9999 digit* 6 Lower Linear An1 only for Default: 0. linear input Input Upper range limit -999…+9999 digit* 7 Upper Linear An1 only for Default: 1000. linear input Input Automatic setting (Disabled) Default 8 of limits for (Standard) Latch On Linear input Function (Virtual Zero Stored) 5 Upper limit Upper Limit setpoint 9 Offset Calibration 10 Gain Calibration 11 Action type 12 Command Reset (Virtual Zero Initialized) Offset calibration -999…+1000 digit* for linear Number added sensors and potentiometers. to displayed -200.0…+100.0 tenths for value of process temperature sensors. (normally Default: 0.0. corrects the room temperature value) Gain calibration -10.0%…+10.0% Value multiplied Default: 0.0. with process value to perform calibration on working point Regulation type : Heating (N.O.) Default : Cooling (N.C.) : HEat Off Over Setpoint Type of reset for (Automatic Reset) state of Default command (Manual Reset) contact (always automatic in PID (Manual Reset Stored) functioning) 31 13 Command State Error 14 Command Led 15 Command Hysteresis State of contact Default for command output in case of error State of the OUT1 led Default corresponding to the relevant contact Hysteresis in -999…+999 digits∗ ON/OFF or dead (tenths of degree if temperature) band in P.I.D. Default: 0.0. Command delay (only in ON/OFF Command functioning). Delay (In case of servo valve it also functions in PID and represents the delay between the opening and closure of the two contacts) Allows or not to 17 Command change the command Setpoint Protection setpoint value Proportional 18 Proportional band Process inertia in Band units (E.g.: if temperature is in °C) 16 ∗ -180…+180 seconds (tenths of second in case of servo valve). Negative: delay in switching off phase. Positive: delay in activation phase. Default: 0. Default 0 on/off if equal to 0. Default 1-9999 digit* (degrees if temperature) The display of the decimal point depends on the setting of parameter and parameter 32 . Integral time. Process inertia in Integral seconds Time Derivative time. 20 Derivative Normally ¼ the integral time Time Cycle time (for 21 Cycle Time PID on remote control switch 10/15sec, for PID on SSR 1 sec) or servo time (value declared by servo-motor manufacturer) Limit of output 22 power % Output 19 0.0-999.9 seconds (0 integral disabled) Default: 0. 0.0-999.9 seconds (0 derivative disabled) Default: 0. 0.1-300.0 seconds Default: 10.0. For motorised valve minimum time in 1.0. 10-100 % Default: 100. Power Limit 23 Alarm 1 Alarm 1 selection. Intervention of the alarm is associated with AL1 (Disabled) Default (Absolute Alarm) (Band Alarm) (High Deviation Alarm) (Low Deviation Alarm) (Absolute Com. setpoint Alarm) (Start Alarm) Active in Run (Cooling) (Timer 1 Start Alarm) (Timer 1 End Alarm) (Timer 2 Start Alarm) (Timer 2 End Alarm) (Timer 1-2 Start Alarm) (Timer 1-2 End Alarm) 33 24 Alarm 1 output (n.o. start) Default contact and Alarm 1 Normally open, active at start State Output intervention type (n.c. start) Normally closed, active at start (n.o. threshold) Normally open, active on reaching alarm4 (n.c. threshold) Normally closed on reaching alarm4 25 Alarm 1 Reset Type of Reset for contact of alarm (Automatic Reset) Default 1 (Manual Reset) (Manual Reset Stored) State of contact Default for alarm 1 Alarm 1 State Error output in case of error State of the 27 Alarm 1 Led OUT2 led Default corresponding to the relative contact Alarm 1 -999…+999 digit∗ 28 hysteresis (tenths of degree if temperature). Alarm 1 Hysteresis Default: 0. Alarm 1 delay -180…+180 Seconds 29 Negative: delay in alarm output phase. Alarm 1 Delay Positive: delay in alarm entry phase. Default: 0. 26 4 On activation, the output is inhibited if the controller is in alarm mode. Activates only if alarm condition reappers, after that it was restored. ∗ The display of the decimal point depends on the setting of parameter and parameter 34 . 30 Alarm 1 Setpoint Protection 31 Alarm 2 Alarm 1 set protection. Does not allow user to modify setpoint Alarm 2 selection. Alarm intervention is associated with AL2 Default (Disabled) Default (Absolute Alarm) (Band Alarm) (High Deviation Alarm) (Low Deviation Alarm) (Absolute Command setpoint Alarm) (Start Alarm) (Cooling) (Timer 1 Start Alarm) (Timer 1 End Alarm) (Timer 2 Start Alarm) (Timer 2 End Alarm) (Timer 1-2 Start Alarm) (Timer 1-2 End Alarm) 32 Alarm 2 output (n.o. start) Default contact and Normally open, active at start intervention type Alarm 2 (n.c. start) State Output Normally closed, active at start (n.o. threshold) Normally open, active on reaching alarm5 (n.c. threshold) Normally closed, active on reaching alarm5 5 On activation, the output is inhibited if the controller is in alarm mode. It activates only if alarm condition reappears after that it was restored. 35 33 34 35 36 37 38 39 Alarm 2 Reset Type of Reset for (Automatic Reset) contact of alarm Default 2 (Manual Reset) (Manual Reset Stored) State of contact Default for alarm 2 Alarm 2 State Error output in case of error State of OUT2 Alarm 2 Led led Default corresponding to relative contact Alarm 2 -999…+999 digit∗ hysteresis (tenths of degree if temperature). Alarm 2 Hysteresis Default: 0. Alarm 2 delay -180…+180 Seconds Negative: delay in alarm output phase. Alarm 2 Delay Positive: delay in alarm entry phase. Default: 0. Alarm 2 set Default protection. Alarm 2 Does not allow Setpoint Protection operator to change value of setpoint Type of cooling Default fluid Cooling Fluid Proportional 40 Proportional band multiplier 1.00-5.00 Default: 1.00. Band Multiplier ∗ The display of the decimal point depends on the setting of parameter and parameter 36 . Overlapping/Dea -20.0-50.0% 41 Overlap/Dea d band Default: 0. d Band 42 Cooling Cycle Time Cycle time for cooling output 1-300 seconds Default: 10. ADC filter: 43 Conversion number of means on Filter analog-digital conversions (Disabled) (2 Samples Mean) (3 Samples Mean) (4 Samples Mean) (5 Samples Mean) (6 Samples Mean) (7 Samples Mean) (8 Samples Mean) (9 Samples Mean) (10 Samples Mean) Default (11 Samples Mean) (12 Samples Mean) (13 Samples Mean) (14 Samples Mean) (15 Samples Mean) Frequency of 44 Conversion sampling of Frequency analog-digital converter (242 Hz) (123 Hz) (62 Hz) (50 Hz) (39 Hz) (33.2 Hz) (19.6 Hz) (16.7 Hz) Default (12.5 Hz) 37 (10 Hz) (8.33 Hz) (6.25 Hz) (4.17 Hz) 45 Visualisation Visualisation filter Filter (Disabled) Default (Pitchfork filter) (First Order) (First Order with Pitchfork) (2 Samples Mean) (3 Samples Mean) (4 Samples Mean) (5 Samples Mean) (6 Samples Mean) (7 Samples Mean) (8 Samples Mean) (9 Samples Mean) (10 Samples Mean) 46 Tune Tuning type selection (Disabled) Default (Automatic) PID parameters are calculated at activation and change of set. (Manual) Launch from keys or digital input. 38 47 Setpoint Deviation Tune 48 Operating Mode Select the 0-5000 digit∗ (tenths of degree if deviation from temperature). the command Default: 10. setpoint, for the threshold used by autotuning to calculate the PID parameters Select operating mode (Controller) Default (Programmed Cycle) (2 Thresholds Switch) (2 Thresholds Switch Impulsive) (3 Thresholds Switch Impulsive) (4 Thresholds Switch Impulsive) Enable 49 Automatic / automatic/manua l selection Manual (Disabled) Default (Enabled) (Enabled Stored) 50 Digital input Digital Input functioning (P48 selection must be or (Disabled) Default: 0. (Start/Stop) (Run n.o.) (Run n.c.) ) (Lock Conversion n.o.) (Lock Conversion n.c.) (Tune) Manual (Auto/Man. impulse) (Auto/Man. Contact) ∗ The display of the decimal point depends on the setting of the parameter and the parameter . 39 51 Increase gradient for soft Gradient start or preprogrammed cycle Maintenance 52 Maintenance time for preprogrammed Time cycle 53 0 disabled 1-9999 Digit/time∗ (degrees/hours with display of tenths if temperature) Default: 0. 00.00-24.00 hh.mm Default: 00.00. (Disabled) Default Allows the rise (Rising Gradient) User Menu gradient and the Cycle maintenance (Maintenance Time) Programmed time to be changed from (Rising Gradient and the user menu, Maintenance Time) in pre(Falling Gradient) programmed (Rising and Falling cycle functioning Gradient) (Falling Gradient and Maintenance Time) (All) 54 Select Visualization visualization for Type display 1 and 2 (1 Process, 2 Setpoint) Default (1 Process, 2 Hide after 3 sec.) (1 Setpoint, 2 Process) (1 Setpoint, 2 Hide after 3 sec.) 55 ∗ Degree Select degree type : Centigrade - Default :Fahrenheit The display of the decimal point depends on the setting of parameter and parameter 40 . 56 Baud Rate Select baud rate for serial communication Select slave address for serial communication Select serial 58 Serial Delay delay 57 Slave Address 59 Master Select the master mode Default 1 – 254 Default: 254. 0 – 100 milliseconds Default: 20. (Disable) Default (Write Process) (Read/Write Command Setpoint) (Write Output Percentage) (Read/Write Alarm 1 Setpoint) Select address 60 Address for Retransmis- retransmission sion Lower limit Lower Limit 61 retransmission Retransmis- range sion ∗ (Read Process) 0x0000 – 0xFFFF (hexadecimal) Default: 0x03E9. -999 – 9999 digit∗ (degrees if temperature) Default: 0. The display of the decimal point depends on the setting of parameter and parameter . 41 Upper limit 62 Upper Limit retransmission Retransmis- range6 sion 63 Timer Function7 64 Falling Gradient7 6 If parameter 61 value is not rescale. 7 -999 – 9999 digit∗ (degrees if temperature) Default: 0. (Disable) Default Enable 1 or 2 (Single Timer Seconds) timers which may be set from (Double Timer Seconds) user menu and which can be (Single Timer Minutes) related to alarms (Double Timer Minutes) Cooling gradient for preprogrammed cycle and 62 Feature only available on specific request. 42 0 desabled (uncontrolled cooling) 1-9999 degrees/hour, with display of tenth Default: 0. have the same value, retransmitted 11 Alarm Intervention Modes Absolute Alarm or Threshold Alarm ( Pv Alarm Spv Hysteresis parameter >0 Time On Off On Off Alarm output Hysteresis parameter <0 Pv Alarm Spv Time On Off On Off Alarm output Time Pv Hysteresis parameter >0 Alarm Spv On Off On Off Alarm output selection) Absolute alarm with controller in heating functioning (Par.11 selected ) and hysteresis value greater than “0” (Par.28 > 0). N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. Absolute alarm with controller in heating functioning (Par.11 selected ) and hysteresis value less than “0” (Par.28 < 0). N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. Absolute alarm with controller in cooling functioning (Par.11 selected ) and hysteresis value greater than “0” (Par.28 > 0). N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. 43 Time Pv Alarm Spv Hysteresis parameter <0 On On Off Alarm output Off Absolute alarm with controller in cooling functioning selected (Par.11 ) and hysteresis value less than “0” (Par.28 < 0). N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. Absolute Alarm or Threshold Alarm Referring to Setpoint Command ( selection) Comand Spv Hysteresis parameter >0 Alarm Spv Time On Off Off Alarm output Absolute alarm refers to the command set, with the controller in heating functioning (Par.11 selected ) and hysteresis value greater than “0” (Par.28 > 0). The command set can be changed by pressing the arrow keys on front panel or using serial port RS485 commands. N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. 44 Band Alarm ( selection) Pv Alarm Spv Hysteresis parameter >0 Comand Spv Alarm Spv Time On On Off On Off Off Comand Spv Time On Off On Off Band alarm hysteresis value less than “0” (Par.28 < 0). Alarm Spv Hysteresis parameter <0 On N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. Alarm output Hysteresis parameter <0 Pv Band alarm hysteresis value greater than “0” (Par.28 > 0). Off N.B.: The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. Alarm output 45 Upper Deviation Alarm ( selection) Pv Alarm Spv Hysteresis parameter >0 Comand Spv Time On Off On Alarm output Off Pv Comand Spv Alarm Spv Hysteresis parameter >0 Time On Off 46 On Off Alarm output Upper deviation alarm value of alarm setpoint greater than “0” and hysteresis value greater than “0” (Par.28 > 0). N.B.: a) The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. b) With hysteresis less than “0” ( < 0) the broken line moves above the alarm setpoint. Upper deviation alarm value of alarm setpoint less than “0” and hysteresis value greater than “0” (Par.28 > 0). N.B.: a) The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. b) With hysteresis less than “0” < 0) the broken line ( moves above the alarm setpoint. Lower Deviation Alarm ( selection) Pv Comand Spv Hysteresis parameter >0 Alarm Spv Time On On Off Off Alarm output Hysteresis parameter >0 Pv Alarm Spv Comand Spv Time On On Off Off Alarm output Lower deviation alarm value of alarm setpoint greater than “0” and hysteresis value greater than “0” (Par.28 > 0). N.B.: a) The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it. b) With hysteresis less than “0” ( < 0) the broken line moves under the alarm setpoint. Lower deviation alarm value of alarm setpoint less than “0” and hysteresis value greater than “0” (Par.28 > 0). N.B.: a) The example refers to alarm 1; the function can also be enabled for alarms 2 and 3 on models that include it b) With hysteresis value less than “0” ( < 0) the broken line moves under the alarm setpoint. 47 12 Table of Anomaly Signals In case of malfunctioning of the system, the controller switches off the regulation output and displays the type of anomaly. For example the controller will signal the breakage of any connected thermocouple by displaying (flashing) on display. For other notifications, see the table below. # E-01 E-02 E-04 E-05 E-06 E-08 48 Cause Error in E²PROM cell programming Cold junction sensor fault or room temperature outside of allowed limits. Incorrect configuration data. Possible loss of calibration values. Thermocouple open or temperature outside of limits. Off-line in master mode remote process Missing calibration data What to do Call Assistance Call Assistance Check if the configuration parameters are correct. Check the connection with the sensors and their integrity. Check the serial connection, baud-rate and device ID . Call Assistance 13 Summary of Configuration parameters Date: Installer: Notes: Model ATR142: System: Command output type selection Analog input configuration Number of decimal points Lower limit setpoint Upper limit setpoint Lower limit range An1 only for linear Upper limit range An1 only for linear Automatic setting of linear input limits. Offset calibration Gain calibration Regulation type Command output reset type Contact state for command output in case of error Define the OUT1 led state Hysteresis in ON/OFF or dead band in P.I.D. Command delay Command setpoint protection Proportional band Integral time Derivative time Cycle time Limit of output power % Alarm 1 selection Alarm 1 output contact and intervention type Reset type of alarm 1 contact. State of contact for alarm 1 output State of OUT2 led 49 Alarm 1 hysteresis Alarm1 delay Alarm 1 set protection Alarm 2 selection Alarm 2 output contact and intervention type Reset type of alarm 2 contact State of contact for alarm 2 output State of OUT2 led Alarm 2 hysteresis Alarm 2 delay Alarm 2 set protection Cooling fluid type Proportional band multiplier Overlapping/Dead band Cycle time for cooling output Analog converter filter Sampling frequency of analog converter Display filter Autotuning type selection Command setpoint deviation for tuning threshold Operating mode Automatic/manual selection Digital input functioning Gradient for soft start Cycle maintenance time Gradient change and maintenance time by user Display data selection Degree type selection Select baud rate for serial communication Select slave address Select the serial delay Select value to retransmit by ModBus Seelct address for retransmission 50 Lower limit of retransmission range Upper limit of retransmission range Timer Function Falling Gradiente Note 51 14 Introduzione Grazie per aver scelto un regolatore Pixsys. Con il modello ATR142 Pixsys rende disponibile in un singolo strumento tutte le opzioni relative alla connessione dei sensori e al comando di attuatori, con in aggiunta un’utile alimentazione a range esteso da 24…230 Vac/Vdc. Con le 17 sonde selezionabili e l’uscita configurabile come relè o SSR l’utilizzatore o il rivenditore può gestire al meglio le scorte di magazzino razionalizzando investimento e disponibilità dei dispositivi. La serie si completa con i modelli dotati di comunicazione seriale RS485 Modbus Rtu. La ripetibilità in serie delle operazioni di parametrizzazione è ulteriormente semplificata dalle nuove Memory Card, dotate di batteria interna che non richiedono cablaggio per alimentare il regolatore. 15 Identificazione del modello La famiglia di regolatori ATR142 prevede due versioni, facendo riferimento alla tabella seguente è facile risalire al modello desiderato. Modelli con alimentazione 24…230 Vac/Vdc ±15% 50/60Hz - 4,6VA ATR142-ABC 2 Relè (8A+5A) + 1 SSR ATR142-ABC-T 1 Relè 8A + 1 SSR + RS485 52 16 Dati tecnici 16.1 Caratteristiche generali Visualizzatori 4 display 0,40 pollici + 4 display 0,30 pollici Temperatura di temperatura funzionamento 0-45°C, umidità esercizio 35..95uR% Protezione IP65 (con guarnizione) su Frontale, contenitore IP30 e morsettiere IP20 Materiale Policarbonato UL94VO autoestinguente Peso Circa 100 g 16.2 Caratteristiche hardware Ingresso AN1 analogici Configurabile via software Ingresso Termocoppie tipo K, S, R, J Compensazione automatica del giunto freddo da 0 … 50°C. Termoresistenze: PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (β 3435K) Ingresso V/I: 0-10V, 0-20 o 4-20mA, 0-40mV Ingresso Pot: 6KΩ, 150KΩ Uscite relè 2 relè (ATR142-ABC) 1 relè (ATR142-ABC-T) Configurabili come uscita comando e allarme. Uscita SSR 1 SSR Configurabili come uscita comando e allarme. Alimentazione Alimentazione a range esteso 24…230Vac/Vdc ±15% 50/60Hz Tolleranza (25°C) +/-0.2 % ± 1 digit per ingresso termocoppia, termoresistenza e V/mA. Precisione giunto freddo 0.1°C/°C Contatti: Q1: 8A-250V~ per carichi resistivi Q2: 5A-250V~ per carichi resistivi 12Vdc/30mA Consumo: 4.6VA 53 16.3 Caratteristiche software Algoritmi regolazione ON-OFF con isteresi. P, PI, PID, PD a tempo proporzionale Banda proporzionale 0...9999°C o °F Tempo integrale 0,0...999,9 sec (0 esclude) Tempo derivativo 0,0...999,9 sec (0 esclude) Funzioni del Tuning manuale o automatico allarme regolatore selezionabile, protezione set comando e allarme, selezione funzioni da ingresso digitale, ciclo preprogrammato con Start/Stop. 17 Dimensioni e installazione Dima di foratura 28.5 x 70.5 mm Frontal panel cut-out Spessore suggerito 2÷8 mm Suggested thickness Guarnizione per 32x74 Cod. 1620.00.082 (optional) Gasket for 32x74 Memory Card (optional) Cod. MEMORY C241 MEMORY C.121 42mm inserimento Memory Card 42mm insert Memory Card Memory Card (optional) with battery Cod. MEMORY C243 U1 C1 35 mm 6 3 77 mm 54 1 NC 2 1 1 7 53 mm 18 Collegamenti elettrici Benché questo regolatore sia stato progettato per resistere ai più gravosi disturbi presenti in ambienti industriali è buona norma seguire la seguenti precauzioni: • Distinguere la linea di alimentazioni da quelle di potenza. • Evitare la vicinanza di gruppi di teleruttori, contattori elettromagnetici, motori di grossa potenza e comunque usare gli appositi filtri. la vicinanza di gruppi di potenza, in particolare se a controllo di fase. • Evitare 18.1 Schema di collegamento Di seguito sono riportati i collegamenti dei due modelli disponibili. PIXSYS ATR142-ABC 2 wire 4/20mA Power 8A 230V Resistive 1/2HP 5A 230V Resistive 1/8HP Q1 Q2 PT/NI100/1K PTC/NTC 1 1 2 3 4 5 6 7 8 9 10 11 12 Memory PIXSYS ATR142-ABC-T 2 wire 4/20mA Power 8A 230V Resistive 1/2HP PT/NI100/1K Q1 PTC/NTC RS485 1 1 2 3 4 5 6 7 8 9 10 11 12 Memory 55 Alimentazione 2 2 4. ..23 0 V A C /D C 1 Alimentazione switching a range esteso 24…230 Vac/dc ±15% 50/60Hz – 3,5VA - 12 + Tc 11 Ingresso analogico AN1 Per termocoppie K, S, R, J. • Rispettare la polarità Shield/Schermo • Per eventuali prolunghe utilizzare cavo compensato e morsetti adatti alla termocoppia utilizzata (compensati) • Quando si usa cavo schermato, lo schermo deve essere collegato a terra ad una sola estremità Per termoresistenze PT100, NI100 • Per il collegamento a tre fili usare cavi Shield/Schermo della stessa sezione. A • Per il collegamento a due fili cortocircuitare i morsetti 10 e 12. B • Quando si usa cavo schermato, lo schermo deve essere collegato a terra ad C una sola estremità 11 PT /NI100 10 12 ROSSO 10 BIANCO 11 ROSSO 12 Shield/Schermo 11 PTC/NTC 10 9 V/ I 12 + 11 +VDC 10 56 Shield/Schermo Per termoresistenze NTC, PTC, PT500, PT1000 e potenziometri lineari. • Quando si usa cavo schermato, lo schermo deve essere collegato a terra ad una sola estremità Per segnali normalizzati in corrente e tensione • Rispettare la polarità • Quando si usa cavo schermato, lo schermo deve essere collegato a terra ad una sola estremità Esempi di collegamento per ingressi normalizzati 12 Per segnali normalizzati in tensione 0….10V 0...10V 11 12 0/4...20mA 11 9 SENSORE DI PRESSIONE Rispettare le polarità Per segnali normalizzati in corrente 0/4….20mA con sensore a tre fili Rispettare le polarità C=Uscita sensore B=Massa sensore A=Alimentazione sensore 12 Per segnali normalizzati in corrente 0/4..20mA con sensore ad alimentazione esterna 0/4...20mA 11 ALIMENTAZIONE ESTERNA Rispettare le polarità C=Uscita sensore B=Massa sensore SENSORE DI PRESSIONE 12 Per segnali normalizzati in corrente 0/4..20mA con sensore a due fili 4...20mA 9 Rispettare le polarità C=Uscita sensore A=Alimentazione sensore SENSORE DI PRESSIONE Ingresso Seriale + 7 R S4 85 - 6 Shield/Schermo RS485, protocol MODBUS-RTU 11 Non usare resistenze di terminazione Per reti con più di cinque strumenti alimentare in bassa tensione 57 Uscite relè 7 Portata contatti: Q1 • Contatto n.o. : 8A/250V~ - ½HP • Contatto n.c.: 8A/250V~ per carichi resistivi Q2 • 5A/250V~ per carichi resistive Q2 6 5 4 Q1 3 Uscita SSR 8 Uscita comando SSR portata 12V/30mA SSR 9 Ingresso digitale 10 Ingresso digitale (parametro ). L’utilizzo dell’ingresso digitale è possibile solo con sonde tipo Tc, 0…10V, 0/4…20mA e 0…40mV. 11 19 Funzione dei visualizzatori e tasti 1 9 12 1 2 M T 10 3 58 4 5 3 R 6 11 7 8 2 19.1 Indicatori numerici (display) Normalmente visualizza il processo. In fase di configurazione visualizza il parametro 1 in inserimento. Normalmente visualizza i setpoint. In fase di 2 configurazione visualizza il valore del parametro in inserimento. 19.2 Significato delle spie di stato (led) 3 Si accendono quando l’uscita comando è attiva. Nel caso di comando valvola motorizzata è acceso nel caso di apertura valvola e lampeggia in chiusura. 4 Si accende quando l’allarme 1è attivo. 5 Si accende quando l’allarme 2 è attivo. 6 Si accende all’attivazione della funzione “Manuale”. 7 Si accende quando il regolatore sta eseguendo un ciclo di Tuning. 8 Si accende quando il regolatore comunica via seriale. 19.3 Tasti 9 • • Incrementa il setpoint principale In fase di configurazione consente di scorrere i parametri. Insieme al tasto • 10 • • 11 SET 12 • • • FNC • li modifica. SET Premuto dopo il tasto incrementa i setpoint di allarme. Decrementa il setpoint principale In fase di configurazione consente di scorrere i parametri. Insieme al tasto • SET SET li modifica. SET Premuto dopo il tasto decrementa i setpoint di allarme. Permette di visualizzare i setpoint di allarme. Permette di variare i parametri di configurazione. Permette di entrare nella funzione di lancio del Tuning, selezione automatico/manuale. Permette di variare i parametri di configurazione. 59 20 Funzioni del regolatore 20.1 Modifica valore setpoint principale e setpoint di allarme Il valore dei setpoint può essere modificato da tastiera come segue: Premere 1 o 2 SET 3 o Effetto Eseguire La cifra sul display 2 varia Incrementare o diminuire il valore del setpoint principale Visualizza setpoint di allarme sul display 1 La cifra sul display 2 varia Incrementare o diminuire il valore del setpoint di allarme 20.2 Auto-tune La procedura di Tuning per il calcolo dei parametri di regolazione può essere manuale o automatica e viene selezionata da parametro 46 . 20.3 Lancio del Tuning Manuale La procedura manuale permette all’utente maggiore flessibilità nel decidere quando aggiornare i parametri di regolazione dell’argoritmo PID. La procedura può essere attivata in due modi. • Lancio del Tuning da tastiera: Premere il tasto FNC finché il display 1 non visualizza la scritta con il display 2 su , premere , il display 2 visualizza . Il led si accende e la procedura ha inizio. • Lancio del Tune da ingresso digitale: Selezionare su parametro 50 . Alla prima attivazione dell’ingresso digitale (commutazione su fronte) il led 60 si accende, alla seconda si spegne. 20.4 Tuning Automatico Il Tuning automatico si attiva all’accensione dello strumento o quando viene modificato il setpoint di un valore superiore al 35%. Per evitare overshoot, il punto dove il regolatore calcola i nuovi parametri PID è determinato dal valore di setpoint meno il valore “Set ) Deviation Tune” (vedere Parametro 47 Per interrompere il Tuning lasciando invariati i valori PID, premere il tasto FNC finché il display 1 non visualizza la scritta e il . display 2 visualizza Premendo , il display 2 visualizza la procedura termina. , il led si spegne e 20.5 Soft Start Il regolatore all’accensione per raggiungere il setpoint segue un gradiente di salita impostato in Unità (es. Grado / ora). Impostare sul parametro 51 il valore di incremento in Unità/Ora desiderato; alla successiva accensione lo strumento eseguirà la funzione Soft Start. Non può essere abilitata la funzione Tuning automatico e manuale se la funzione Soft Start è attiva. 20.6 Regolazione automatico / manuale per controllo % uscita Questa funzione permette di passare dal funzionamento automatico al comando manuale della percentuale dell’uscita. Con il parametro 49 • Selezione è possibile selezionare due modalità. (Enable). NC Premendo il tasto F visualizza la scritta mentre sul display 2 appare . Premere il tasto sul display 1, per selezionare la modalità manuale . Con i tasti e variare la percentuale di uscita. 61 Per tornare in automatico, con la stessa procedura, selezionare sul display 2: subito si spegne il led torna in automatico. • • • e il funzionamento Selezione (enable stored) Abilita lo stesso funzionamento, ma con due importanti varianti: Nel caso di temporanea mancanza di tensione o comunque dopo uno spegnimento, accendendo il regolatore verrà mantenuto sia il funzionamento in manuale, sia il valore di percentuale dell’uscita precedentemente impostato. Nel caso di rottura del sensore durante il funzionamento automatico, il regolatore si porterà in manuale mantenendo invariata la percentuale di uscita comando generata dal PID subito prima della rottura. 20.7 Ciclo pre-programmato Questa funzione permette di programmare un semplice ciclo di lavoro temporizzato, e si abilita impostando nel parametro 48 : il processo raggiunge il setpoint1 in base al gradiente impostato nel parametro 51 , poi sale alla massima potenza verso il setpoint 2. Quando il processo raggiunge il setpoint 2 resta in . Allo mantenimento per il tempo impostato nel parametro 52 scadere, il processo raggiunge la temperatura ambiente in base al gradiente impostato nel parametro 64 comando viene disabilitata e lo strumento visualizza e poi l’uscita di . Lo Start del ciclo avviene al ogni accensione dello strumento, oppure da ingresso digitale se risulta abilitato per questo tipo di funzionamento (vedi parametro 50 ). 62 20.8 Memory Card (opzionale) E’ possibile duplicare parametri e setpoint da un regolatore ad un altro mediante l’uso della Memory Card. Sono previste due modalità: • Con regolatore connesso all’alimentazione: Inserire la Memory Card con regolatore spento. All’accensione il display 1 visualizza e il display 2 visualizza (Solo se nella Memory sono salvati valori corretti). Premendo il tasto il display 2 visualizza . FNC Confermare con il tasto . Il regolatore carica i nuovi valori e riparte. • Con regolatore non connesso all’alimentazione: La memory card è dotata di batteria interna con autonomia per circa 1000 utilizzi. Inserire la memory card e premere il tasto di programmazione. Durante la scrittura dei parametri il led si accende rosso, al termine della procedura si accende verde. E’ possibile ripetere la procedura senza particolari attenzioni. Aggiornamento Memory Card. Per aggiornare i valori della Memory seguire il procedimento descritto nella prima modalità, impostando sul display 2 in modo da 2 non caricare i parametri sul regolatore . Entrare in configurazione e variare almeno un parametro. Uscendo dalla configurazione il salvataggio sarà automatico. 2 Nel caso in cui all’accensione il regolatore non visualizzi significa che non ci sono dati salvati nella Memory Card, ma è possibile ugualmente aggiornarne i valori. 63 20.9 Caricamento valori di default Questa procedura permette di ripristinare le impostazioni di fabbrica dello strumento. Premere 1 FNC per 3 secondi. 2 o 3 SET per conferma Effetto Su display 1 compare con la 1° cifra lampeggiante, mentre sul display 2 compare Si modifica la cifra lampeggiante si passa alla Eseguire Inserire la password ET successiva con il tasto S Lo strumento carica le impostazioni di fabbrica Spegnere e riaccendere lo strumento 20.10 Funzione LATCH ON Per l’impiego con ingresso (pot. 6KΩ) e (pot.150KΩ) e con ingressi normalizzati (0…10V, 0...40mV, 0/4…20mA), è ) alla possibile associare il valore di inizio scala (parametro 6 posizione di minimo del sensore e quello di fine scala (parametro 7 ) alla posizione di massimo del sensore (parametro 8 configurato come ). E’ inoltre possibile fissare il punto in cui lo strumento visualizzerà 0 (mantenendo comunque il campo scala compreso tra e ) tramite l’opzione di “zero virtuale” impostando oppure nel parametro 8 . Se si imposta lo zero virtuale andrà reimpostato dopo ogni accensione dello strumento; se si imposta 64 lo zero virtuale resterà fisso una volta tarato. Per utilizzare la funzione LATCH ON configurare come desiderato il .8 parametro Per la procedura di taratura fare riferimento alla seguente tabella: Premere 1 FNC Effetto Esce dalla configurazione parametri. Il display 2 visualizza la Il display visualizza (associato a ) Posizionare il sensore sul valore massimo di funzionamento Fissa il valore sul massimo. (associato a ) Per uscire dalla procedura standard scritta . 2 Fissa il valore sul minimo. 3 Il display visualizza 4 SET Eseguire Posizionare il sensore sul valore minimo di funzionamento NC premere F . Nel caso di impostazione con “zero virtuale” posizionare il sensore nel punto di zero. Fissa il valore di zero virtuale. Per uscire dalla procedura tenere Il display visualizza N.B.: nel caso di selezione premuto FNC . la procedura al punto 4 va eseguita ad ogni ri-accensione. MAX MIN 8 ZERO La procedura di taratura parte uscendo dalla configurazione dopo aver variato il parametro. 65 20.11 Funzioni da Ingresso digitale L’utilizzo dell’ingresso digitale abilita alcune funzioni utili a semplificare l’operatività del regolatore. Selezionare la funzione desiderata sul . parametro 50 1. Funzione Hold: si abilitata impostando o e permette di bloccare la lettura delle sonde quando l’ingresso digitale è attivo. Risulta utile quando la misura oscilla molto sui valori meno significativi. Durante la fase di blocco il display 2 lampeggia visualizzando . 2. Abilita / disabilita il Tuning da ingresso digitale se il parametro è impostato su 3. Abilita regolazione con . o . 4. Passa da funzionamento automatico a manuale se impostato su o è . 5. Start del ciclo preprogrammato con ( vedi paragrafo 20.7). 6. E’ possibile utilizzare l’ingresso digitale per la funzione di “Cambio Setpoint”. Questo funzionamento è utile nel caso ci siano da 2 a 4 soglie di lavoro che si vogliono richiamare da pulsante senza dover agire sui tasti freccia durante il funzionamento dell’impianto. , Per abilitare la funzionalità agire sul parametro 48 selezionando il numero di setpoint desiderati (n. Thresholds switch). Questi potranno essere impostati durante il funzionamento premendo il tasto SET . N.B.: Le funzioni da ingresso digitale non sono disponibili con sonde PT100, NI100, NTC, PTC, PT500, PT1000 e potenziometri lineari. 66 20.12 Funzionamento in doppia azione (caldo-freddo) L’ATR142 è adatto alla regolazione anche su impianti che prevedano un’azione combinata caldo-freddo. L’uscita di comando deve essere configurata in PID caldo ( = e maggiore di 0), e uno degli allarmi ( oppure ) deve essere configurato come . L’uscita di comando va collegata all’attuatore responsabile dell’azione caldo, l’allarme comanderà invece l’azione refrigerante. I parametri da configurare per il PID caldo sono: = Tipo azione uscita di comando (Caldo) : Banda proporzionale azione caldo : Tempo integrale azione caldo ed azione freddo : Tempo derivativo azione caldo ed azione freddo : Tempo di ciclo azione caldo I parametri da configurare per il PID freddo sono (azione associata, per esempio, all’allarme1): = Selezione Allarme1 (Cooling) : Moltiplicatore di banda proporzionale : Sovrapposizione / Banda morta : Tempo di ciclo azione freddo Il parametro (che varia da 1.00 a 5.00) determina la banda proporzionale dell’azione refrigerante secondo la formula: * Banda proporzionale azione refrigerante = Si avrà così una banda proporzionale per l’azione refrigerante che sarà uguale a quella dell’azione caldo se = 1.00, o 5 volte più grande se = 5.00. Tempo integrale e Tempo derivativo sono gli stessi per entrambe le azioni. Il parametro determina la sovrapposizione in percentuale tra le due azioni. Per gli impianti in cui l’uscita riscaldante e l’uscita refrigerante non devono mai essere attive contemporaneamente si 67 ≤ 0), viceversa si potrà configurerà una Banda morta ( configurare una sovrapposizione ( > 0). La figura seguente riporta un esempio di PID doppia azione (caldofreddo) con =0e = 0. (COOL) * SPV <0 PV (HEAT) ACTIVE ACTIVE COMMAND OUTPUT (HEAT) ALARM OUTPUT (COOL) (COOL) * =0 SPV (HEAT) PV ACTIVE ACTIVE COMMAND OUTPUT (HEAT) ALARM OUTPUT (COOL) (COOL) * >0 SPV (HEAT) PV ACTIVE ACTIVE 68 COMMAND OUTPUT (HEAT) ALARM OUTPUT (COOL) Il parametro ha lo stesso significato del tempo di ciclo per l’azione caldo . Il parametro (Cooling Fluid) pre-seleziona il moltiplicatore di ed il tempo di ciclo banda proporzionale freddo in base al tipo di fluido refrigerante: Tipo di fluido refrigerante Aria Olio Acqua Una volta selezionato il parametro e 1.00 1.25 2.50 , i parametri del PID 10 4 2 , possono essere comunque modificati. 21 Comunicazione Seriale 21.1 Slave L’ATR142-ABC-T con RS485 può ricevere e trasmettere dati via seriale tramite protocollo MODBUS RTU. Il dispositivo funziona come è impostato su . Questa slave se il parametro 59 funzione permette il controllo di più regolatori collegati ad un sistema di supervisione. Ciascuno strumento risponderà ad un’interrogazione del Master solo se questa contiene l’indirizzo uguale a quello contenuto nel parametro . Gli indirizzi permessi vanno da 1 a 254 e non devono esserci regolatori con lo stesso indirizzo sulla stessa linea. L’indirizzo 255 può essere usato dal Master per comunicare con tutte le apparecchiature collegate (modalità broadcast), mentre con 0 tutti i dispositivi ricevono il comando, ma non è prevista alcuna risposta. L’ATR142 può introdurre un ritardo (in millisecondi) della risposta alla richiesta del Master. Tale ritardo deve essere impostato sul parametro 58 69 Ad ogni variazione dei parametri lo strumento salva il valore in memoria EEPROM (100000 cicli di scrittura), mentre il salvataggio dei setpoint avviene con un ritardo di 10 secondi dall’ultima modifica. NB: Modifiche apportate a Word diverse da quelle riportate nella tabella seguente possono causare mal funzionamenti dello strumento. Caratteristiche protocollo Modbus RTU Baud-rate Selezionabile da parametro 56 4800bit/sec 9600bit/sec 19200bit/sec 28800bit/sec 38400bit/sec 57600bit/sec Formato 8, N, 1 (8bit, no parità, 1 stop) Funzioni WORD READING (max 20 word) (0x03, 0x04) supportate SINGLE WORD WRITING (0x06) MULTIPLE WORDS WRITING (max 20 word) (0x10) Si riporta di seguito l’elenco di tutti gli indirizzi disponibili, dove: RO = Read Only R/W = Read / Write WO = Write Only Modbus address 0 1 5 6 50 51 70 Descrizione Read Write Reset value Tipo dispositivo Versione software Address slave Versione boot Indirizzamento automatico Confronto codice impianto RO RO R/W RO WO WO EEPROM EEPROM EEPROM EEPROM - 500 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 Caricamento valori di default: 9999 ripristina tutti i valori 9998 ripristina tutti i valori escluso baudrate e address slave 9997 ripristina tutti i valori escluso address slave 9996 ripristina tutti i valori escluso baudrate Processo (gradi con decimo per sensori di temperatura; digit per sensori normalizzati) Setpoint1 Setpoint2 Setpoint3 Setpoint4 Allarme1 Allarme2 Setpoint gradiente Stato uscite (0=off, 1=on) Bit 0 = relè Q1 Bit 1 = relè Q2 Bit 2 = SSR Percentuale uscita caldo (0-10000) Percentuale uscita freddo (0-10000) Stato allarmi (0=assente, 1=presente) Bit0 = Allarme 1 Bit1 = Allarme 2 Riarmo manuale: scrivere 0 per riarmare tutti gli allarmi. In lettura (0=non riarmabile, 1=riarmabile): Bit0 = Allarme 1 Bit1 = Allarme 2 RW 0 RO ? R/W R/W R/W R/W R/W R/W RO RO EEPROM EEPROM EEPROM EEPROM EEPROM EEPROM EEPROM 0 RO 0 RO 0 RO 0 WO 0 71 1013 1014 1015 1016 1017 1018 1019 1100 1101 1102 1103 1104 1 Flags errori Bit0 = Errore scrittura eeprom Bit1 = Errore lettura eeprom Bit2 = Errore giunto freddo Bit3 = Errore processo (sonda) Bit4 = Errore generico Bit5 = Errore hardware Bit6 = Master off-line Bit7 = Taratura mancante Temperatura giunto freddo (gradi con decimo) Start/Stop 0=regolatore in STOP 1=regolatore in START Lock conversion ON/OFF 0=Lock conversion off 1=Lock conversion on Tuning ON/OFF 0=Tuning off 1=Tuning on Selezione automatico/manuale 0=automatico 1=manuale Tempo OFF LINE1 (millisecondi) Processo visualizzato (decimale come sul display) Setpoint1 visualizzato (decimale come sul display) Setpoint2 visualizzato (decimale come sul display) Setpoint3 visualizzato (decimale come sul display) Setpoint4 visualizzato (decimale come sul display) RO 0 RO ? R/W 0 R/W 0 R/W 0 R/W 0 R/W RO 0 ? R/W EEPROM R/W EEPROM R/W EEPROM R/W EEPROM Se vale 0 il controllo è disabilitato. Se diverso da 0, è “Il tempo massimo che può trascorrere tra due interrogazioni senza che il regolatore si porti in Off-Line”. In Off-Line il regolatore va in stato di Stop, disabilita l’uscita di comando, ma mantiene gli allarmi attivi. 72 1105 1106 1107 1108 1109 1110 1111 2001 2002 ... 2062 3000 3001 …… 3008 3009 …… 3016 3017 3018 2 Allarme1 visualizzato (decimale come sul display) Allarme2 visualizzato (decimale come sul display) Setpoint gradiente (decimale come sul display) Percentuale uscita caldo (0-1000) Percentuale uscita caldo (0-100) Percentuale uscita freddo (0-1000) Percentuale uscita freddo (0-100) Parametro 1 Parametro 2 ... Parametro 62 Disabilitazione controllo macchina da seriale2 Prima word display1 (ascii) …. Ottava word display1 (ascii) Prima word display2 (ascii) …. Ottava word display2 (ascii) Word LED Bit 0 = LED 1 Bit 1 = LED 2 Bit 2 = LED 3 Bit 3 = LED MAN Bit 4 = LED TUN Bit 5 = LED REM Word tasti (scrivere 1 per assumere il controllo dei tasti) Bit 0 = Bit 2 = Bit 1 = Bit 3 = R/W EEPROM R/W EEPROM RO EEPROM RO RO RO RO R/W R/W ... R/W WO 0 0 0 0 EEPROM EEPROM ... EEPROM 0 R/W R/W R/W R/W R/W R/W R/W 0 0 0 0 0 0 0 R/W 0 SET FNC Scrivendo 1 su questa word, si annullano gli effetti della scrittura su tutti gli indirizzi Modbus da 3001 a 3019. Il controllo ritorna così al regolatore. 73 3019 3020 3021 Word uscite seriale R/W Bit 0 = relè Q1 Bit 1 = relè Q2 Bit 2 = uscita SSR Word stato uscite seriale in caso di off-line R/W Bit 0 = relè Q1 Bit 1 = relè Q2 Bit 2 = uscita SSR Word processo seriale R/W 0 0 0 21.2 Master Il dispositivo funziona come master se il valore impostato sul parametro 59 è diverso da . 21.2.1 Modalità master in ritrasmissione In questa modalità lo strumento scrive il valore da ritrasmettere all’indirizzo impostato sul parametro 60 , su altri slave che hanno ID uguale al valore impostato sul parametro 57 . Per la ritrasmissione dei setpoint dopo l’avvenuta scrittura sullo slave, l’ATR142 inizia a leggere la word selezionata: in questo modo un’eventuale variazione del valore sullo slave viene appreso anche dal master. Due interrogazioni successive vengono ritardate del tempo impostato su parametro 57 Nella seguente tabella sono riportate le selezioni che permettono il funzionamento master in ritrasmissione e la relativa grandezza ritrasmessa Descrizione Scrive il valore del processo Write Process Read/Write Command Setpoint Write Output Percentage Read/Write Alarm 1 74 Scrive e legge il valore del setpoint di comando Scrive la percentuale di uscita calcolata dal P.I.D. (Range 0-10000) Scrive e legge il valore del setpoint dell’allarme 1 Il valore letto/scritto può essere riscalato seguendo la proporzione proposta nella seguente tabella: Limiti valore ingresso Min. Max. Limiti valore riscalato Min. Max. Write Process Lower Limit Input Upper Limit Input Lower Limit Retransmission Upper Limit Retransmission Read/Write Command Setpoint Lower Limit Setpoint Upper Limit Setpoint Lower Limit Retransmission Upper Limit Retransmission Write Output Percentage 0 10000 Lower Limit Retransmission Upper Limit Retransmission Read/Write Alarm 1 Setpoint Lower Limit Setpoint Upper Limit Setpoint Lower Limit Retransmission Upper Limit Retransmission Il valore in ingresso (compreso tra i limiti minimo e massimo) viene trasformato in maniera lineare nel valore in ritrasmissione compreso tra i valori minimo e massimo in uscita. e La riscalatura non viene eseguita se i parametri hanno lo stesso valore. 21.2.2 Modalità master processo remoto Per abilitare questo funzionamento bisogna impostare sul parametro 59 . In questa modalità l’ATR142 legge un valore da remoto e lo imposta come processo. Lo slave deve avere un ID uguale a quello impostato sul parametro 57 e la word da leggere è selezionata sul parametro 60 . Due interrogazioni successive vengono ritardate del tempo impostato su parametro 57 Il valore letto può essere riscalato seguendo la proporzione proposta nella seguente tabella: 75 Limiti valore letto Read Process Limiti valore riscalato Min. Max. Min. Max. Lower Limit Retransmission Upper Limit Retransmission Lower Limit Input Upper Limit Input 22 Configurazione 22.1 Modifica parametro di configurazione Per parametri di configurazione vedi Par. 23. Premere Effetto Su display 1 compare FNC con la 1° cifra lampeggiante, mentre sul 1 per 3 secondi. 2 display 2 compare Si modifica la cifra lampeggiante si passa alla o successiva con il tasto 3 SET per conferma 4 o 5 SET + o 6 FNC 76 Eseguire Inserire la password SET Su display 1 compare il primo parametro e sul secondo il valore. Scorre i parametri Si incrementa o decrementa il valore visualizzato premendo prima SET e poi un tasto freccia. Fine variazione parametri di configurazione. Il regolatore esce dalla programmazione. Inserire il nuovo dato che verrà salvato al rilascio dei tasti. Per variare un altro parametro tornare al punto 4 23 Tabella parametri di configurazione L'elenco dei parametri sotto riportato è completo; alcuni di questi non appariranno sui modelli che non dispongono delle relative risorse Hardware. n. 1 Display Descrizione parametro Range di inserimento Selezione tipo Command uscita di comando Output Default ATR142-ABC COMANDO ALLARME 1 ALLARME 2 Q2 Q1 SSR Q1(apri) Q2(chiudi) Q1 Q2 Q1 SSR SSR SSR Q2 - ATR142-ABC-T COMANDO ALLARME 1 Q1 SSR Q1(apri) SSR(chiudi) SSR Q1 - 77 n. Display 2 Sensor Descrizione parametro Range di inserimento Configurazione Tc-K -260…1360°C ingresso (Default) analogico Tc-S -40…1760°C Tc-R -40…1760°C Tc-J -200…1200°C PT100 -200…600°C PT100 -200…140°C NI100 -60…180°C NTC10K -40…125°C PTC1K -50…150°C PT500 -100…600°C PT1000 100…600°C 0…10Volt 0…20mA 4…20mA 0…40mVolt Potenz.Max 6KΩ F.S. Potenz.Max 150KΩF.S. 3 Decimal Point Seleziona il tipo di decimale visualizzato Limite inferiore setpoint 4 Lower Limit Setpoint ∗ Default -999…+9999 digit∗ (gradi se temperatura) Default: 0. La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro 78 . 5 6 7 8 Limite Upper Limit superiore setpoint Setpoint Limite inferiore range An1 solo Lower Linear Input normalizzati Limite superiore Upper Linear Input range An1 solo normalizzati Impostazione automatica dei limiti per Latch On Function ingressi lineari. 9 Offset Calibration 10 Gain Calibration 11 Calibrazione offset Numero che si somma al processo visualizzato (normalmente corregge il valore di temperatura ambiente) Calibrazione guadagno Valore che si moltiplica al processo per eseguire calibrazioni sul punto di lavoro. Tipo di regolazione -999…+9999 digit* (gradi se temperatura) Default: 1750. -999…+9999 digit* Default: 0. -999…+9999 digit* Default: 1000. (Disabled) Default (Standard) (Virtual Zero Stored) (Virtual Zero Initialized) -999…+1000 digit* per sensori normalizzati e potenziometri. -99.9…+100.0 decimi per sensori di temperatura. Default: 0.0. -99.9%…+100.0% Default: 0.0. : caldo (N.A.) Default : freddo (N.C.) :Blocca comando sopra Action type SPV 79 12 13 14 15 16 ∗ Tipo di riarmo del contatto di Command comando Rearmament (sempre automatico in funzionamento PID). Stato del Command contatto per State Error l’uscita di comando in caso di errore. Definisce lo stato del led Command OUT1 in Led corrispondenza del relativo contatto Isteresi in Command ON/OFF o Hysteresis banda morta in P.I.D. Ritardo comando (solo Command in Delay funzionamento ON/OFF). (In caso di servo valvola funziona anche in PID e rappresenta il ritardo tra l’apertura e la chiusura dei due contatti) (Automatic Rearmament) Default (Manual Rearmament) (Manual Rearmament Stored) Default Default -999…+999 digit∗ (decimi di grado se temperatura) Default: 0.0. -180…+180 secondi (decimi di secondo in caso di servo valvola). Negativo: ritardo in fase di spegnimento. Positivo: ritardo in fase di accensione. Default: 0. La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro 80 . 17 18 19 20 21 22 23 Consente o Command meno di variare il valore del Setpoint Protection setpoint di comando Banda Proportional proporzionale Inerzia del Band processo in unità (Esempio: se temperatura in °C) Tempo integrale. Integral Inerzia del Time processo in secondi Tempo Derivative derivativo Normalmente Time ¼ del tempo integrale Tempo ciclo (per PID su Cycle Time teleruttore 10/15sec, per PID su SSR 1 sec) o tempo servo (valore dichiarato da produttore del servomotore) Limite del segnale di Output Power Limit comando Selezione allarme 1. Alarm 1 L’intervento dell’allarme è associato a Default 0 on/off se uguale a 0. Default 1-9999 digit* (gradi se temperatura) 0.0-999.9 secondi (0 integrale disabilitato) Default: 0. 0.0-999.9 secondi (0 derivativo disabilitato) Default: 0. 0.1-300.0 secondi Default: 10.0. Per servo-valvole il tempo minimo impostabile è 1.0 secondi. 10-100 % Default: 100. (Disabled) Default (Absolute Alarm) (Band Alarm) 81 AL1. (High Deviation Alarm) (Low Deviation Alarm) (Absolute Command setpoint Alarm) (Start Alarm) Attivo in Run (Cooling) (Timer 1 Start Alarm) (Timer 1 End Alarm) (Timer 2 Start Alarm) (Timer 2 End Alarm) (Timer 1-2 Start Alarm) 24 Alarm 1 State Output (Timer 1-2 End Alarm) Contatto uscita (n.o. start) Default allarme 1 e tipo Normalmente aperto attivo allo intervento start (n.c. start) Normalmente chiuso attivo allo start (n.o. threshold) Normalmente aperto attivo al raggiungimento dell’allarme9 (n.c. threshold) Normalmente chiuso attivo al raggiungimento dell’allarme4 25 Alarm 1 Rearmament Tipo di riarmo del contatto dell’allarme 1. (Automatic Rearmament) Default (Manual Rearmament) (Manual Rearmament Stored) 9 All’accensione, l’uscita è inibita se lo strumento è in condizione di allarme. Si attiva solo quando rientrato dalla condizione d’allarme, questa si ripresenta. 82 26 27 28 29 30 31 Stato del Default contatto per Alarm 1 State Error l’uscita di allarme 1 in caso di errore. Definisce lo stato del led Default Alarm 1 Led OUT2 in corrispondenza del relativo contatto Isteresi allarme -999…+999 digit∗ 1 (decimi di grado se Alarm 1 Hysteresis temperatura). Default: 0. Ritardo -180…+180 Secondi allarme 1 Negativo: ritardo in fase di uscita dall’allarme. Alarm 1 Positivo: ritardo in fase di entrata Delay dell’allarme. Default: 0. Protezione set Default allarme 1. Alarm 1 Non consente Setpoint Protection all’utente di variare il setpoint. Selezione (Disabled) Default allarme 2. (Absolute Alarm) Alarm 2 L’intervento dell’allarme è (Band Alarm) associato a (High Deviation Alarm) AL2. (Low Deviation Alarm) (Absolute Command setpoint Alarm) (Start Alarm) (Cooling) ∗ La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro . 83 (Timer 1 Start Alarm) (Timer 1 End Alarm) (Timer 2 Start Alarm) (Timer 2 End Alarm) (Timer 1-2 Start Alarm) (Timer 1-2 End Alarm) Contatto uscita (n.o. start) Default 32 allarme 2 e tipo Normalmente aperto attivo allo Alarm 2 State Output intervento start (n.c. start)Normalmente chiuso attivo allo start (n.o. threshold) Normalmente aperto attivo al raggiungimento dell’allarme10 (n.c. threshold) Normalmente chiuso attivo al raggiungimento dell’allarme5 33 Alarm 2 Tipo di riarmo del contatto dell’allarme 2. Rearmament (Automatic Rearmament) Default (Manual Rearmament) (Manual Rearmament Stored) 34 35 10 Alarm 2 State Error Stato del contatto per l’uscita di allarme 2 in caso di errore. Definisce lo stato del led Alarm 2 Led OUT2 in corrispondenza del relativo contatto Default Default All’accensione, l’uscita è inibita se lo strumento è in condizione di allarme. Si attiva solo quando rientrato dalla condizione d’allarme, questa si ripresenta. 84 36 Alarm 2 Hysteresis 37 Alarm 2 Delay 38 Alarm 2 Setpoint Protection 39 40 Cooling Fluid Isteresi allarme -999…+999 digit∗ 2 (decimi di grado se temperatura). Default: 0. Ritardo allarme -180…+180 Secondi 2 Negativo: ritardo in fase di uscita dall’allarme. Positivo: ritardo in fase di entrata dell’allarme. Default: 0. Protezione set Default allarme 2. Non consente all’operatore di variare il valore impostato. Tipo di fluido Default refrigerante Moltiplicatore di 1.00-5.00 Default: 1.00. Proportional banda proporzionale Band Multiplier Sovrapposizione -20.0-50.0% 41 Overlap/Dead / Banda Morta Default: 0. Band 42 43 ∗ Tempo ciclo per uscita Cooling Cycle Time refrigerante Filtro adc: numero di Conversion medie Filter effettuate sulle conversioni analogicodigitali. 1-300 secondi Default: 10. (Disabled) (2 Samples Mean) (3 Samples Mean) (4 Samples Mean) (5 Samples Mean) La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro . 85 (6 Samples Mean) (7 Samples Mean) (8 Samples Mean) (9 Samples Mean) (10 Samples Mean) Default (11 Samples Mean) (12 Samples Mean) (13 Samples Mean) (14 Samples Mean) (15 Samples Mean) 44 Frequenza di Conversion Frequency (242 Hz) campionamento (123 Hz) del convertitore analogicodigitali. (62 Hz) (50 Hz) (39 Hz) (33.2 Hz) (19.6 Hz) (16.7 Hz) Default (12.5 Hz) (10 Hz) (8.33 Hz) (6.25 Hz) (4.17 Hz) 45 Filtro in Visualization visualizzazione Filter (Disabled) Default (Pitchfork filter) (First Order) (First Order with Pitchfork) (2 Samples Mean) 86 (3 Samples Mean) (4 Samples Mean) (5 Samples Mean) (6 Samples Mean) (7 Samples Mean) (8 Samples Mean) (9 Samples Mean) (10 Samples Mean) Selezione tipo autotuning. 46 Tune 47 Setpoint Deviation Tune 48 Seleziona la deviazione dal setpoint di comando, per la soglia usata dall’ autotuning, per il calcolo dei parametri PID. Selezione funzionamento Operatine Mode (Disabled) Default (Automatic) Calcolo parametri PID all’accensione e al variare del set (Manual) Lanciato dai tasti o da ingresso digitale. 0-5000 digit∗ (decimi di grado se temperatura). Default: 10. (Controller) Default (Programmed Cycle) (2 Thresholds Switch) (2 Thresholds Switch Impulsive) (3 Thresholds Switch Impulsive) ∗ La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro . 87 (4 Thresholds Switch Impulsive) 49 50 Abilita la selezione Automatic / automatico/ma Manual nuale. Funzionamento ingresso Digital Input digitale ( selezione P48 deve essere (Disabled) Default (Enabled) (Enabled Stored) (Disabled) Default: 0. (Start/Stop) (Run n.o.) (Run n.c.) (Lock Conversion n.o.) oppure (Lock Conversion n.c.) ) (Tune) Manuale (Automatic Manual impulse) 51 52 (Automatic Manual Contact) 0 disabilitato Gradiente di salita per Soft 1-9999 Digit/ora∗ Gradient Start o ciclo (gradi/ora con visualizzazione preprogrammato del decimo se temperatura) Default: 0. Tempo 00.00-24.00 hh.mm mantenimento Default: 00.00. Maintenance per ciclo Time 53 ∗ preprogrammato Permette di modificare User Menù gradiente di Cycle salita e tempo Programmed di mantenimento dal menù (Disabled) Default (Rising Gradient) (Maintenance Time) (Rising Gradient and Maintenance Time) (Falling Gradient) La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro 88 . utente in funzionamento ciclo preprogrammato (Rising and Falling Gradient) (Falling Gradient and Maintenance Time) (All) 54 Imposta la visualizzione Visualization sul Type display 1 e 2. (1 Process, 2 Setpoint) Default (1 Process, 2 Hide dopo 3 sec.) (1 Setpoint, 2 Process) (1 Setpoint, 2 Hide dopo 3 sec.) Selezione tipo gradi 55 Degree 56 Baud Rate 57 Slave Address 58 :gradi centigradi (Default) :gradi Fahrenheit Seleziona il baud rate per la comunicazione seriale Seleziona l’ID dello slave per la comunicazione seriale Seleziona il ritardo seriale Default 0 – 255 Default: 254. 0 – 100 millisecondi Default: 20. Serial Delay 59 Master Seleziona la modalità master. (Disable) Default (Write Process) (Read Write Command Setpoint) (Write Output Percentage) 89 (Read Write Alarm 1 Setpoint) 60 61 Lower Limit Retransmission 62 Upper Limit Retransmission 63 Timer Function12 64 ∗ Address Retransmission Falling Gradient12 (Read Process) Seleziona 0x0000 – 0xFFFF (esadecimale) l’indirizzo per la Default: 0x03E9. ritrasmissione Limite inferiore range ritrasmissione -999 – 9999 digit∗ (gradi se temperatura) Default: 0. Limite superiore range ritrasmissione11 Abilita 1 o 2 timer impostabili da menù utente e collegabili agli allarmi -999 – 9999 digit∗ (gradi se temperatura) Default: 0. (Disable) Default (Single Timer Seconds) (Double Timer Seconds) (Single Timer Minutes) (Double Timer Minutes) 0 disabilitato Gradiente di (raffreddamento naturale) discesa per ciclo 1-9999 gradi/ora con preprogrammato visualizzazione del decimo Default: 0. La visualizzazione del punto decimale dipende dall’impostazione del parametro e del parametro 11 Se il parametro 61 e il 62 ritrasmesso non viene rescalato. 12 . hanno lo stesso valore il valore Funzione disponibile solo su specifica richiesta. 90 24 Modi d’intervento allarme Allarme assoluto o allarme di soglia (selezione ) Allarme assoluto con regolatore Pv in funzionamento caldo selezionato Alarm Spv (Par.11 ) e valore di isteresi Hysteresis parameter maggiore di “0” >0 (Par.28 > 0). N.B.:L’esempio è riferito all’allarme 1; la funzione è Time abilitabile anche per gli allarmi On On Alarm 2 e 3 sui modelli che li Off Off output prevedono. Hysteresis Allarme assoluto con regolatore Pv parameter < 0 in funzionamento caldo (Par.11 selezionato Alarm Spv ) e valore di isteresi minore di “0” < 0). (Par.28 N.B.:L’esempio è riferito Time all’allarme 1; la funzione è On On abilitabile anche per gli allarmi Alarm Off Off output 2 e 3 sui modelli che li prevedono. Allarme assoluto con regolatore Time Pv in funzionamento freddo selezionato Hysteresis (Par.11 parameter ) e valore di isteresi >0 maggiore di “0” Alarm Spv (Par.28 > 0). N.B.:L’esempio è riferito all’allarme 1; la funzione è On On abilitabile anche per gli allarmi Alarm Off Off output 2 e 3 sui modelli che li prevedono. 91 Time Pv Alarm Spv Hysteresis parameter <0 On Off On Off Alarm output Allarme assoluto con regolatore in funzionamento freddo selezionato (Par.11 ) e valore di isteresi minore di “0” (Par.28 < 0). N.B.:L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. Allarme assoluto o allarme di soglia riferito al setpoint di comando (selezione ) Allarme assoluto riferito al set di comando, con regolatore in Comand Spv funzionamento caldo Hysteresis (Par.11 selezionato parameter >0 ) e valore di isteresi maggiore di “0” (Par.28 Alarm Spv > 0). Il set di comando può essere Time variato con la pressione dei tasti freccia da frontale o con On Alarm comandi su porta seriale Off Off output RS485. N.B.:L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. 92 Allarme di Banda (selezione Pv Alarm Spv Hysteresis parameter >0 Comand Spv Alarm Spv Time On On Off On Off Off Alarm output Hysteresis parameter <0 Pv Comand Spv Time On Off On Off Allarme di banda valore di isteresi maggiore di “0” (Par.28 > 0). N.B.:L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. Allarme di banda valore di isteresi minore di “0” (Par.28 < 0). Alarm Spv Hysteresis parameter <0 On ) Off Alarm output N.B.:L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. 93 Allarme deviazione superiore (selezione Pv Alarm Spv Hysteresis parameter >0 Comand Spv Time On Off On Alarm output Off Pv Comand Spv Alarm Spv Hysteresis parameter >0 Time On Off 94 On Off Alarm output ) Allarme di deviazione superiore valore di setpoint allarme maggiore di “0” e valore di isteresi maggiore di “0” (Par.28 > 0). N.B.: a) L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. b) Con isteresi minore di “0” ( < 0) la linea tratteggiata si sposta sopra il Setpoint di allarme. Allarme di deviazione superiore valore di setpoint allarme minore di “0” e valore di isteresi maggiore di “0” (Par.28 > 0). N.B.: a) L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. b) Con isteresi minore di “0” ( < 0) la linea tratteggiata si sposta sopra il Setpoint di allarme. Allarme deviazione inferiore (selezione Pv Comand Spv Hysteresis parameter >0 Alarm Spv Time On On Off Off Alarm output Hysteresis parameter >0 Pv Alarm Spv Comand Spv Time On On Off Off Alarm output ) Allarme di deviazione inferiore valore di setpoint allarme maggiore di “0” e valore di isteresi maggiore di “0” > 0). (Par.28 N.B.: a) L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. b) Con isteresi minore di “0” ( < 0) la linea tratteggiata si sposta sotto il Setpoint di allarme. Allarme di deviazione inferiore valore di setpoint allarme minore di “0” e valore di isteresi maggiore di “0” (Par.28 > 0). N.B.: a) L’esempio è riferito all’allarme 1; la funzione è abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono. b) Con isteresi minore di “0” ( < 0) la linea tratteggiata si sposta sotto il Setpoint di allarme. 95 25 Tabella segnalazioni anomalie In caso di mal funzionamento dell'impianto il controllore spegne l’uscita di regolazione e segnala il tipo di anomalia riscontrata. Per esempio il regolatore segnalerà la rottura di un’eventuale termocoppia collegata visualizzando (lampeggiante) sul display. Per le altre segnalazioni vedi la tabella sottostante. # E-01 E-02 E-04 E-05 E-06 E-08 96 Causa Errore in programmazione cella E²PROM. Guasto sensore temperatura giunto freddo o temperatura ambiente al di fuori dei limiti ammessi. Dati di configurazione errati. Possibile perdita della tarature dello strumento. Termocoppia aperta o temperatura fuori limite. Fuori linea in caso di funzionamento master con processo remoto Taratura mancante Cosa Fare Chiamare Assistenza Chiamare Assistenza Verificare che i parametri di configurazione siano corretti. Controllare il collegamento con le sonde e la loro integrità. Controllare il collegamento seriale, il baud-rate e l’ID dei moduli Chiamare Assistenza 26 Promemoria configurazione Data: Installatore: Note: Modello ATR142: Impianto: Selezione tipo uscita di comando Configurazione ingresso analogico Seleziona il tipo di decimale visualizzato Limite inferiore setpoint Limite superiore setpoint Limite inferiore range An1 solo per normalizzati Limite superiore range An1 solo per normalizzati Impostazione automatica dei limiti per ingressi lineari. Calibrazione offset Calibrazione guadagno Tipo di regolazione Tipo di riarmo del contatto di comando Stato del contatto per l’uscita di comando in caso di errore. Definisce lo stato del led OUT1 Isteresi in ON/OFF o banda morta in P.I.D. Ritardo comando Protezione del setpoint di comando Banda proporzionale Tempo integrale Tempo derivativo Tempo ciclo Limite del segnale di comando Selezione allarme 1 Contatto uscita allarme 1 e tipo intervento Tipo di riarmo del contatto dell’allarme 1. Stato del contatto per l’uscita di allarme 1 Stato del led OUT2 97 Isteresi allarme 1 Ritardo allarme 1 Protezione set allarme 1 Selezione allarme 2 Contatto uscita allarme 2 e tipo intervento Tipo di riarmo del contatto dell’allarme 2 Stato del contatto per l’uscita di allarme 2 Stato del led OUT2 Isteresi allarme 2 Ritardo allarme 2 Protezione set allarme 2 Tipo di fluido refrigerante Moltiplicatore di banda proporzionale Sovrapposizione / Banda Morta Tempo ciclo per uscita refrigerante Filtro convertitore analogico Frequenza di campionamento del convertitore analogico Filtro in visualizzazione Selezione tipo autotuning Deviazione dal setpoint di comando, per la soglia tuning Selezione funzionamento Selezione automatico/manuale Funzionamento ingresso digitale Gradiente di salita per Soft Start Tempo mantenimento per ciclo Modificare gradiente e tempo di mantenimento da utente Selezione visualizzazione sui display Selezione tipo gradi Seleziona il baud rate per la comunicazione seriale Seleziona l’indirizzo dello slave 98 Seleziona il ritardo seriale Seleziona la grandezza da ritrasmettere tramite ModBus Seleziona l’indirizzo per la ritrasmissione Limite inferiore range ritrasmissione Limite superiore range ritrasmissione Funzione Timer Gradiente di discesa Note / Aggiornamenti 99 PIXSYS Via Tagliamento, 18 30030 Mellaredo di Pianiga (VE) www.pixsys.net e-mail: [email protected] - [email protected] Software Rev. 1.06 2300.10.092-RevE 210909 *2300.10.092-E* 100