Download AMP51Pure User Manual
Transcript
AMP51Pure User Manual Martin Clausen 5.11.2010 1 Main Menu or more times, corresponding to the nesting of the sub menu. 1.1 Volume 1.4 Mute Press in the main menu Fup or Fdown until Volume is displayed. Adjust now the volume with the encoder to the desired value Press the mute button to switch o the out- in the range from -96 to 15.5 dB. put. To activate the output, press Mute again. If Input is selected in the main menu, the volume can be increased with Select and decreased with Exit in 2.5 dB steps. 1.5 Standby 1.2 Input Selection To toggle between power on and standby mode, press in the main menu the standby Press in the main menu Fup or Fdown until button. Input is displayed. Select now the input In the standby mode the display back light can be switched on and o with with the encoder. In the lower right corner the mute button. of the display the preamplication is shown. If the input is mono, in the upper right cor- 1 1.5.1 ner mono is displayed and the mono LED Time Timer in the Standby Mode will be on. If Volume is selected in the main menu, To adjust the One Time Timer, press in the input can be changed with Select and the standby mode Select. Exit. Now the time will be displayed, at which the amp will switch itself one time on. 1.3 Options is the absolute time. Fdown the digit. Press in the main menu Fup or Fdown until Note that this Select with Fup and The encoder is used to adjust the value of the digit. Option is displayed. Press now Select. To To activate the alarm, leave the menu with Select. Use get back to the main menu press Exit one 1 2*20 One Exit to deactivate the alarm and leave the character LCD only menu. When the One Time Timer is active, 1 2.4 Address of the Remote Control 2 THE OPTION MENU OTT" will be visible in the lower right cor- the option menu Fup or Fdown until Bal- ner of the display. ance is displayed. Now select the desired attenuation via the encoder. Mute resets to 2 neutral. If the position is not neutral a B The Option Menu will be displayed in the lower right corner of the display 2 and the balance LED will be 2.1 Preamplication on. For each input an individual preamplicaset. Press in the option menu Fup or Fdown 2.4 Address of the Remote Control until Gain is displayed. tion factor between 0 and 15.5 dB can be Press now Se- To use the remote control of other devices, In the rst line of the display now the remote control address can be set. Press the name of the input is shown. In the sec- in the option menu Fup or Fdown until Se- ond line the gain is displayed. Select now lect RC is displayed. Press now Select and with Fup or Fdown the input and adjust afterward any key at the remote control. with the encoder the preamplication. Se- Now the device address as well as the key lect with Mute between mono and stereo code is shown. The device address is used mode. With the Standby button the input for the amplier, while the key code is just channel can be deactivated. A deactivated displayed for your information. lect. channel is marked by disabled and will be hidden in the main menu. 2.5 Power Up Status 2.2 Naming of the Inputs When the power supply is switched on, the For each input a name with an maximum To adjust this, press in the option menu length of 16 charters can be given. Press in Fup or Fdown until Power up Status is the option menu Fup or Fdown until Input displayed. Name is displayed. with Fup or Fdown the mode. Press now Select. device can enter standby or power up mode. In Press now Select. Then select the second line of the display now the name 2.6 Set the Clock of the input is shown. Select now with Fup or Fdown the input and press the select. Select now with Fup and Fdown the digit and To adjust the clock, press in the option adjust with the encoder the charter. mute menu Fup or Fdown, until Set Clock" is sets the actual charter to space. displayed. Press now Select. Then the time can be adjusted. Use Fup and Fdown to select the digit and the encoder to adjust 2.3 Balance the value. Conrm the setting with Se- lect. Now the date can be adjusted in the For the left or the right output an attenua- 2 2*20 tion between 0 and 64 can be set. Press in 2 character LCD only 2 THE OPTION MENU same way. 2.9 Dynamic Step Size Control 2.9 Dynamic Step Size Control After conrmation of the date the week day can be set via the encoder. To When now Select is pressed, the years un- access the wide adjustment range quickly, a dynamic step size control is im- til the next leap year can be entered. Now plemented in the software. The presets are press again Select to get back to the option Step Dynamic 9 steps and Clear Step Time menu. 2 seconds. 2.7 Programming Alarms of 2.9.1 the Step Dynamic Step dynamic is the speed with which the step size increases when the same key is To adjust an alarm, press in the option pressed several times. menu Fup or Fdown until Set Alarm" is menu Fup or Fdown until Step Dynamic" is displayed. Select now displayed. Press now Select and adjust af- with Fup or Fdown an alarm and con- terward via the encoder the step dynamic. rm with Select. Adjust now rst volume, A high value corresponds to a low accelera- then input, time and week day. tion. Press now Select. Conrm Press in the option the week day with Select to activate the alarm. Press Exit to leave and deactivate 2.9.2 the alarm. Clear Step Time Clear step time is the time, after which the step size is reset to one. Press in the option menu Fup or Fdown until Clear Step Time" 2.8 Adjust the Sleep Timer is displayed. Press now Select. Then the value is adjustable via encoder. To adjust the sleep timer, press in the option menu Fup or Fdown until Sleep is dis- 2.10 Display Clock played. Press now Select. Now the time will be displayed, at which the amp will switch Note that this is the Here the user can control, if the time and Select with Fup or Fdown date are shown on the rst line of the dis- the digit and adjust the value with the en- play after one minute of inactivity. Press in coder. Conrm and activate the sleep timer the option menu Fup or Fdown until Dis- with Select. Press Exit to leave the menu play Clock" is displayed. Press now Select. and deactivate the sleep timer. In the main Then select with Fup or Fdown the mode. itself one time o. absolute time. menu a S is displayed in the upper right 3 2.11 Fluorescence Display corner of the display , when the sleep timer is active. The following options are only available, 3 2*20 character LCD only when a uorescence display is used. 3 3 2.11.1 Brightness sage Device reset / Check battery is displayed. The warning has to be ac- The brightness for power on and standby mode is individually adjustable. knoledged by pressing any key. Press as soon as possible. Brightness" or Stdby Brightness" is disPress now Select. It is recommended to replaces the battery in the option menu Fup or Fdown until played. FURTHER INFORMATION • The bright- If the amplier is driven to hard, ness of the corresponding mode can now be the message Clipping" will be shown adjusted via the encoder. in the display and the volume will A low standby brightness is recommended to increase the be decreased automatically. lifetime of the display. able signal is produced by for example A suit- TDA7293. 2.11.2 Display On-Time • If an error occurs, the amplier is Here the user can control, if and in case switched o and the message Amp after which time the uorescence display is switched o" is displayed. powered down during standby. Press in the • option menu Fup or Fdown until Display On-Time" is displayed. The remote control is blocked while the option menu or any security function is Press now Select. active. Then the value in minutes is adjustable via encoder. Mute sets the value to disabled. • Alarms and One Time Timer are executed only in the standby mode. 3 Further Information • • menu. At the rec-output is the preamplied signal available. • It is independent of • Only RC5 remote control units are supprogrammable remote controls. • The device can be reset to factory defaults, pressed while the power is switched on. To prevent an unintended reset the key Tsel has to be pressed when the question Reset device to default? appears. • Calculation of the volume value: B = Balance N = N eutral V olef f = V olume + Gain ( B , for B < N V olef f N V olR = V olef f , other ( V olef f , for B < N V olL = 2N −B V olef f N , other when Fup and Fdown are during, This description is for the software version 17. ported. This code is supported by most • Sleep and One Time Timer are deactivated only after execution. volume and attenuation settings. • Sleep is executed only in the main If the settings get corrupted during power-o, a reset is forced and the mes- 4 3 FURTHER INFORMATION • Balance display: N − B, neutral, V alue = B − N, for B for B <N =N other 5