UNIT MODEL
ARGO 245C
CONDENSATE PUMP (PC)
Model
Rating
Nominal intput
Coil resistance (at 20° C)
SAFETY FLOAT SWITCH (FS)
Model
Contact rating
FLAP MOTOR (FLP)
Type
Model
Rating
Coil resistence (Ambient temp. 25°C)
4 WAYS VALVE (20S)
Model
Coil rating
Coil resistence (Ambient temp. 20°C)
HEAT EXCHANGER COIL (EVAPORATOR)
Coil
Rows
Fin pitch
Face area
HEAT EXCHANGER COIL (CONDENSER)
Coil
Rows
Fin pitch
Face area
THERMOSTATIC VALVE DRAIN PAN
Model
Open
Close
Stroke
B
ARGO 235H
291036
220-240VAC~50Hz
5W - 0,05A
778 ± 8%
Ω
BI 1300 2725
230 V AC/DC - 0,5 A
Ω
Ω
Stepping motor
MP24GA1
DC 12V
WHT-BLU (respectively 4 wires) : 380 ± 7%
-------
SQ-136
AC 220V, 50 Hz, 6W
1440 ± 5%
mm
m2
Alunimium plate fin / copper tube
3
1,6
0,107
mm
m2
Alunimium plate fin / copper tube
4
1,3
0,111
---
°C
°C
mm
-------
DP 25-1101-07 or
DP 25-1107
4,4
15,5
5,16
OPERATING RANGE
Cooling only model
Cooling
Dry
Temperature
Maximum
Minimum
Maximum
Minimum
Indoor air intake temp.
32° C DB/ 23° C WB
19° C DB/ 14° C WB
32° C BS/ 80% R.U.
16° C BS/ 80% R.U.
Outdoor air intake temp.
43° C DB
19° C DB
43° C DB
16° C DB
Temperature
Maximum
Minimum
Maximum
Minimum
Maximum
Minimum
Indoor air intake temp.
32° C DB/ 23° C WB
19° C DB/ 14° C WB
27° C DB
//
32° C BS/ 80% R.U.
16° C BS/ 80% R.U.
Outdoor air intake temp.
43° C DB
19° C DB
24° C DB / 18° C WB
-8° C DB / -9° C WB
43° C DB
16° C DB
Heat pump model
Cooling
Heating
Dry
5