Download ZigBee USB Adapter ProBee
Transcript
ProBee-ZS10 User Guide Rev.1.1 5 AT Command Reference 5.1 Command Line Format Each command line is composed of a prefix, body and terminator. Only “AT” can be used for the prefix. The body is a string of characters. The terminator is <CR> or <NL>. A command can be one of the followings: Read a configuration parameter: AT<Command>?<CR> Do something: AT<Command><CR> Write a configuration parameter: AT<Command>=<Parameter 1>,<Parameter 2>,<Parameter 3>, …<CR> Commands denoted with a “+” character are extended AT commands. S-registers are supported. Multiple commands in the same command line are not supported. 5.2 Standard AT Commands 5.2.1 AT Description Check the state of the connection bet ween host and ProBee device. Execute AT<CR> Response OK<CR> 5.2.2 ATB Description Enter the broadcast data mode. Every data is packetized at intervals of inter character timeout (S12) and transmit range is determined by broadcast range(S35). Execute ATB<CR> Response OK<CR> 5.2.3 ATD Enter the unicast data mode to specific node. If there’s no argument after the Description command, it will connect to the preconfigured destination IEEE address. Successful transmission guarantees successful reception and every data is packetized at intervals of inter character timeout(S12). Execute ATD<CR> Response OK<CR> or ERROR<CR> ATD<nodeID><CR> ATD<IEEE><CR> 31