Download Operating Instructions Busch Temperaturregler - Busch

Transcript
1473-1-8396 │ 11.03.2014
Operating Instructions
Busch Temperaturregler
Pos : 2 /#N eus truktur #/Online-Dokumentation (+KN X)/Titelbl ätter/T emper aturregler/Titelbl att 1099 @ 37\mod_1373543431500_15.doc x @ 298504 @ @ 1
Temperature controllers
1099 UHK
1099 UHKEA
=== Ende der Liste für T extmar ke Cover ===
Operating Instructions
Busch Temperaturregler
Pos : 4 /#N eus truktur #/Online-Dokumentation (+KN X)/Inhalts verz eic hnis (--> Für alle D okumente <--)/Inhalts verz eichnis @ 19\mod_1320649044386_15.doc x @ 109653 @ @ 1
1
2
3
4
5
6
7
8
9
Safety ....................................................................................................................................................................... 3
Intended use ............................................................................................................................................................ 3
Environment ............................................................................................................................................................. 3
Setup and function ................................................................................................................................................... 4
4.1
Features of function and equipment ........................................................................................................ 4
Operation ................................................................................................................................................................. 4
Offset function .......................................................................................................................................................... 5
Technical data.......................................................................................................................................................... 5
Installation and electrical connection ....................................................................................................................... 6
8.1
Requirements for the electrician ............................................................................................................. 6
8.2
Mounting ................................................................................................................................................. 6
8.3
Electrical connection ............................................................................................................................... 8
Commissioning ........................................................................................................................................................ 9
=== Ende der Liste für T extmar ke TOC ===
Operating Instructions | 1473-1-8396
—2—
Operating Instructions
Busch Temperaturregler
Safety
Pos : 6 /#N eus truktur #/Online-Dokumentation (+KN X)/Ü bersc hriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.doc x @ 103357 @ 1 @ 1
1
Safety
Pos : 7 /#N eus truktur #/Online-Dokumentation (+KN X)/Sicherheits hinweis e und Hi nweis e (--> F ür all e D okumente <--)/Warnhinweis e/Sicherheit - 230 V @ 18\mod_1302606816750_15.doc x @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos : 8 /#N eus truktur #/Online-Dokumentation (+KN X)/Ü bersc hriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bes timmungsgemäß er Gebrauc h @ 18\mod_1302763321316_15.doc x @ 103483 @ 1 @ 1
2
Intended use
Pos : 9 /#N eus truktur #/Online-Dokumentation (+KN X)/Bes timmungsgemäß er Gebrauc h (--> Für alle Dokumente <--)/Bus ch-Di mmer /Besti mmungsgemäß er Gebr auch @ 23\mod_1335350449857_15.doc x @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter
"Setup and function".
Pos : 10 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/U - Z/U mwelt @ 18\mod_1302614158967_15.doc x @ 103383 @ 1 @ 1
3
Environment
Pos : 11 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Hinweis e - U mwelt/Hi nweis - U mwelt - Hi nweis El ektr ogeräte @ 18\mod_1302763973434_15.doc x @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos : 12 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Hinweis e - U mwelt/Hi nweis - U mwelt - Entsorgung Elektroger äte @ 20\mod_1325760695972_15.doc x @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the
packaging material and electric devices and their components via the authorized collecting depots and disposal
companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and
the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos : 13 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8396
—3—
Operating Instructions
Busch Temperaturregler
Setup and function
Pos : 14 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/A - F /Aufbau und Funkti on @ 11\mod_1279185435352_15.doc x @ 83027 @ 1 @ 1
4
Setup and function
Pos : 15 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/T emperaturregler /Ver wendung 1099 @ 37\mod_1373543224390_15.doc x @ 298487 @ @ 1
The temperature controller is used to control the temperature in closed rooms.
Application only for de-energized closed actuating drives.
Pos : 16 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/A - F /Funkti ons- und Aus stattungs mer kmal e @ 23\mod_1336557630140_15.doc x @ 209136 @ 2 @ 1
4.1
Features of function and equipment
Pos : 17 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Aufbau und Funkti on/T emperaturregler /Funkti onen 1099 @ 37\mod_1373543826093_15.doc x @ 298519 @ @ 1
1099 UHKEA
1099 UHK
With manual switch for switchover between cooling/OFF/heating
With external input for switchover between heating and cooling.
5
Operation
Pos : 18 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/A - F /Bedi enung @ 11\mod_1279185541649_15.doc x @ 83043 @ 1 @ 1
Pos : 19 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Bedi enung/T emperaturregler /Bedi enung - 1099 @ 37\mod_1373544541890_15.doc x @ 298567 @ @ 1
Pos : 21 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Bedi enung/T emperaturregler /Bedi enung - 1099 @ 37\mod_1373544541890_1.doc x @ 298566 @ 1 @ 4
1099 UHKEA
Fig. 1:
1099 UHK
Operation
No.
Function
A
LED red
Operating mode "Heating"
LED blue
Operating mode "Cooling"
B
Sliding switch at 1099 UHKEA for selecting function B
C
Control knob for selecting the desired room temperature
Pos : 20 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8396
—4—
Operating Instructions
Busch Temperaturregler
Offset function
Pos : 21 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/M - O/Offset-Funkti onen @ 37\mod_1373544905078_15.doc x @ 298599 @ 2 @ 1
6
Offset function
Pos : 22 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Bedi enung/T emperaturregler /Ei nstellungen Off-Set - 1099 @ 37\mod_1373544852375_15.doc x @ 298583 @ @ 1
Fig. 2:
Offset function
Reaching the selected room temperature strongly depends on the ambient conditions such as heating/cooling
system capacity (5 K/h min.), room size, ambient temperature, insulation etc.
That is why the values in the scale are merely guide values. To obtain a setting that is as accurate as possible,
the adjusting knob (1) can be offset in 4 stages by a total of +/-6°C.
To do so, pull off the control knob and cut off the position lug (2) on its underside using a suitable tool.
Then shift the control knob by the desired correction temperature in relation to the vertical and put it back on.
Pos : 23 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/S - T /Technisc he Daten @ 11\mod_1279185386320_15.doc x @ 83019 @ 2 @ 1
7
Technical data
Pos : 24 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Technisc he Daten/T emperaturr egler/T echnisc he Daten 1099 @ 37\mod_1373544943578_15.doc x @ 298615 @ @ 1
General
Nominal voltage
230 V ~ ±10%, 50 / 60 Hz
Switching capacity (inductive) heating
10 (4) A, 230 V ~
Switching capacity (inductive) cooling
5 (2) A, 230 V ~
Connection
1.5 mm² … 2.5 mm²
Temperature adjustment range
~ 5 to 30°C (1 = 5°C | 2 = 10°C | 3 = 15°C | 4 = 20°C | 5 = 25°C | 6 = 30°C)
Switching temperature difference *
Approx. +/- 0.5 K
Protection type
IP 20, (EN 60529)
Power loss (Relay off)
0.5 W
Switch contact (independent normally open
2
contact)
Mode of operation (DIN EN 60730-1)
1B
Degree of contamination (DIN EN 60730-1)
2
Rated surge voltage (DIN EN 60730-1)
4000 V
*
Typical control operation can not always be attained for cooling areas close to the floor. When the device
heats up due to high current loads, the set value should be checked especially in cooling operating mode and,
if necessary, the set-point temperature should be raised.
Pos : 25 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8396
—5—
Operating Instructions
Busch Temperaturregler
Installation and electrical
connection
Pos : 26 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/M - O/M ontage und el ektrisc her Anschl uss @ 23\mod_1336477157864_15.doc x @ 209033 @ 3 @ 1
8
Installation and electrical connection
Pos : 27 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 23\mod_1336558868201_15.doc x @ 209164 @ @ 1
Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
– Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos : 28 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sic herheit - F ac hkenntniss e @ 23\mod_1336559183027_15.doc x @ 209179 @ 2 @ 1
8.1
Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
•
Incorrect installation endangers your life and that of the user of the electrical system.
•
Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
•
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
•
Use suitable personal protective clothing.
•
Use only suitable tools and measuring devices.
•
Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos : 29 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/M - O/M ontage @ 18\mod_1302615960458_15.doc x @ 103424 @ 2 @ 1
8.2
Mounting
Pos : 30 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Sic herheits hinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sic herheit - 230 V @ 18\mod_1302606816750_15.doc x @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos : 31 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8396
—6—
Operating Instructions
Busch Temperaturregler
Installation and electrical
connection
Pos : 32 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/alle Geräte/M ontage - U P-Dos en - D IN 49073-1 oder geeignetes Aufputzgehaeus e - Ohne Doc vari abl e @ 25\mod_1340354979636_15.doc x @ 219890 @ @ 1
The flush-mounted insert must only be installed in flush-mounted wall boxes according to DIN 49073-1, Part 1, or
suitable surface-mounted housings.
Pos : 33 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Montage/T emper aturregler/M ontag e 1099 @ 37\mod_1373545684031_15.doc x @ 298631 @ @ 1
Note
Use only in dry rooms!
Fig. 3:
Installation
No.
Function
A
Height: 150 cm/minimum distance: 30 cm
B
Avoid mounting on thermal bridges
C
Avoid draught and direct sunlight
D
Avoid the heat radiation of external devices
Fig. 4:
Position for putting on the adjustment wheel
Fig. 5:
Putting on the adjustment wheel
To put on the adjustment wheel, turn the two arrows towards each other (1). The position lug (3) on the
adjustment wheel (2) can now be put on in its normal vertical position.
Pos : 34 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8396
—7—
Operating Instructions
Busch Temperaturregler
Installation and electrical
connection
Pos : 35 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/2. Ebene/A - F /El ektrisc her Ansc hluss @ 21\mod_1328177051724_15.doc x @ 138042 @ 2 @ 1
8.3
Electrical connection
Pos : 36 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Ansc hlus s/T emperaturregl er/Ansc hlus s 1099 @ 37\mod_1373546314562_15.doc x @ 298647 @ @ 1
1099 UHKEA
1099 UHK
Fig. 6:
Connection to a 2-pipe system
Fig. 7:
Connection to a 4-pipe system
1099 UHKEA
Terminal designation
1099 UHK
Assignment
Input 1099 UHK for switchover to cooling mode
Output for controlling the heating load
Output for controlling the cooling load
Note
At high humidity (tendency toward thunder storms) during cooling mode, attention should be paid
to dew formation on the cooled surface.
Cooling should be reset early or switched off completely to prevent moisture from damaging the
cooled surface.
Pos : 37 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Steuer modul e - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
Operating Instructions | 1473-1-8396
—8—
Operating Instructions
Busch Temperaturregler
Commissioning
Pos : 38 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Übersc hriften (--> Für all e D okumente <--)/1. Ebene/G - L/Inbetriebnahme @ 11\mod_1279185496977_15.doc x @ 83035 @ 2 @ 1
9
Commissioning
Pos : 39 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Inbetriebnahme/T emperaturregler /Inbetriebnahme - 1099 @ 37\mod_1373547005250_15.doc x @ 298663 @ @ 1
Note
When the temperature controller is used for the first time, it has to be taken into account that the
switching point precision is not reached until about 1-2 hours of operation after installation.
It is recommended to set a temperature that is higher (heating operation) or lower (cooling
operation) than actually desired, to reduce the time required for initial adaptation.
=== Ende der Liste für T extmar ke Content ===
Operating Instructions | 1473-1-8396
—9—
Operating Instructions
Busch Temperaturregler
A member of the ABB Group
Busch-Jaeger Elektro GmbH
PO box
58505 Lüdenscheid
Freisenbergstraße 2
58513 Lüdenscheid
Germany
www.BUSCH-JAEGER.de
[email protected]
Central sales service:
Phone:
+49 (0) 2351 956-1600
Fax:
+49 (0) 2351 956-1700
Notice
We reserve the right to at all times make
technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time
of ordering apply to all orders. ABB accepts no
responsibility for possible errors or
incompleteness in this document.
We reserve all rights to this document and the
topics and illustrations contained therein. The
document and its contents, or extracts thereof,
must not be reproduced, transmitted or reused by
third parties without prior written consent by ABB.
Copyright© 2014 Busch-Jaeger Elektro GmbH
All rights reserved
=== Ende der Liste für T extmar ke Bac kc over ===
1473-1-8396 | 11.03.2014
Pos : 41 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Rüc ksei ten (--> Für alle Dokumente <--)/Rüc ks eite - BJ E-Variante @ 32\mod_1357201421897_15.doc x @ 262132 @ @ 1