Download Installation and operating instructions
Transcript
Water sensor with transmitter Normal working condition The red light blinks in intervals. When the 2 ends of the pins of the water sensor are electrically bridged the red light will be on and an audio signal is sent as long as the 2 pins have an electric contact. The transmitter sends a wireless alarm signal to the control unit and the valve closes. Fault condition 1. The red light does not blink in intervals. Please check on the power supply. 2. The red light is blinking and the audio signal is sent. Possibly the 2 pins of the sensors are bridged by cleaning fluids. Please dry the 2 contacts with a paper tissue. 3. The water sensor is detecting water but the control unit does not react. Please check the wireless transmission range from the installation position of the water sensor transmitter to the control unit with the remote control. 4. The red light is blinking in short intervals and the water sensor shows no reaction. The water sensor has an internal problem and has to be replaced. Rev.: en-2014-02-12 Page 29 of 39