Download Broan 744SFL Instructions / Assembly

Transcript
MODEL 744SFL
Page 3
WIRING OPTION #1 – Allow s f an to operate in automatic mode or
manual mode ( f or odor c ontrol) by c y c ling ON/ OFF sw itc h.
MODEL 68W
2-FUNCTION CONTROL
(PURCHASE SEPARATELY)
LIGHT
(ON/OFF)
BLU
RED
LIGHT
COM
ORG
FAN
(AUTO/OFF)
GRD
BLK
BLK
BRN
WHT
HUMIDITY
CONTROL
4. Hang and secure housing.
Hang unit from nails. Check to make sure that there will be a 1/8”
gap between bottom of housing and ceiling material. Pound nails
tight. For wide joist centers: A #8 x 3/8 self-tapping screw can be
used to join extended brackets together and create a rigid mount.
To ensure a noise-free mount, crimp the bracket channels tightly
around mounting brackets.
120 BLK
VAC GRD
LINE
IN WHT
WHT
FAN
GRD
WHT
WHT
WHT
SWITCH
UNIT
WIRING OPTION #2 – Allow s f an to operate in automatic mode
or manual mode ( f or odor c ontrol) by c y c ling ON/ OFF sw itc h.
Fan alw ay s on w ith light.
MODEL 68W
2-FUNCTION CONTROL
(PURCHASE SEPARATELY)
LIGHT &
FAN
(ON/OFF)
FLUSH
RED
BLU
LIGHT
COM
ORG
FAN
(AUTO/OFF)
GRD
BLK
BLK
HUMIDITY
CONTROL
120 BLK
VAC GRD
LINE WHT
IN
FAN
WHT
BRN
WHT
WHT
GRD
WHT
WHT
SWITCH
UNIT
7. Connect wiring.
5. Attach damper/duct connector.
Snap the damper/duct connector onto housing. Make sure that
tabs on the connector lock in housing slots. (Top of damper/duct
connector will be flush with top of housing.) Install ductwork.
Unit can be wired from outside of housing as shown. Use UL
approved connectors to wire per local codes.
FINISHED
CEILING
MATERIAL
VERTICAL
POWER CABLE
CONNECTION
HORIZONTAL POWER CABLE
CONNECTION
6. Choose power cable direction.
Remove wiring plate. When re-attached, the wiring plate allows
the power cable to enter unit horizontally or vertically.
CLEARANCE
HOLE
HOUSING
COLLAR
8. Finish ceiling.
Cut an opening in finished ceiling material for housing collar.