Download Wacker 0007659 Instructions / Assembly
Transcript
Maintenance 5.4 PG 2A / 3A Adjusting the Impeller Clearance See Graphic: wc_gr000838 If it is necessary to replace impeller or volute, be sure clearance between impeller and volute is adjusted correctly. The impeller (a) should be as close to the volute (b) as possible without rubbing against it. Clearance is adjusted by adding or removing shims (c) from behind impeller. To adjust the clearance do the following: 5.4.1 Remove pump housing but do not remove impeller. 5.4.2 Measure the distance (d) of volute. 5.4.3 Measure the distance (e) of impeller. 5.4.4 Subtract the distance (e) from (d). (d) - (e) = (f) clearance. 5.4.5 The clearance between the volute and the impeller should be 0.3 mm (0.012 in.) to 0.7 mm (0.028 in.). Adjust the distance by removing the impeller and adding shims as needed. Each shim measures 0.3 mm (0.012 in.). As the impeller wears down, additional shims may be required to maintain the clearance between the impeller and the volute. Check the clearance whenever the mechanical seal (g), impeller, volute, or rear flange plate are replaced. e d b g f c a wc_gr000838 28 wc_tx000178gb.fm