Download Tecumseh AWG4525EXNHN Performance Data Sheet
Transcript
AWG4525EXNHN_REV1 TPC - February 14, 2014 TECUMSEH OUTDOOR CONDENSING UNIT Model BOM Air Cooled Application Refrigerant Volts-Hz-Ph AWG4525EXNHN 32L2191-2E* 2 HP High Temp R22 208-230/60/1 36.25 35.38 34.62 26.08 25.50 23.50 4.24 SUCTION 7/8" AWG4525EXNHN Overall Dimensions, inch (mm) L W H 26.55 (674) 28.94 (735) 26.08 (662) Line connections Suction Liquid 7/8" 3/8" Pumpdown o 90% @ 90 F 23.26 lbs Air flow SCFM 1500 LIQUID3/8" Oil Ch. Gross weight Lbs. (kg) Oz. 300 (136) 38.6 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator T, °F 10 15 20 25 30 35 40 45 50 55 PSIG 32.8 37.7 43.0 48.8 54.9 61.5 68.5 76.0 84.0 92.6 BTUH 13400 15100 17000 19100 21200 23500 25800 28300 30900 33700 80°F Watts Cond T 1850 92 1940 93 2040 95 2130 97 2230 99 2330 101 2420 103 2520 106 2620 108 2710 111 BTUH 12000 13700 15500 17500 19500 21600 23800 26200 28600 31200 90°F Watts Cond T 1890 102 2000 104 2100 105 2210 107 2320 109 2430 111 2530 113 2640 115 2750 118 2860 120 o Ambient Temperatures 95°F BTUH Watts Cond T 11400 1920 107 13000 2030 108 14800 2140 110 16700 2250 112 18600 2360 114 20700 2470 116 22900 2590 118 25100 2700 120 27500 2820 122 29900 2940 125 o Performance @ 60 Hz, Return Gas Temperature 65 F, --- SubCooling 5 F * OPTION CODE: See reverse side for Available Options BTUH 10700 12300 14100 15900 17800 19800 21900 24000 26300 28700 100°F Watts Cond T 1940 112 2050 113 2170 115 2290 117 2400 118 2520 120 2640 122 2760 125 2890 127 3010 129 BTUH 9500 11000 12600 14300 16100 17900 19900 21900 24000 26100 110°F Watts Cond T 1980 122 2110 123 2230 125 2360 126 2490 128 2620 130 2750 132 2880 134 3010 136 3150 138 AWG4525EXNHN_REV1 TPC - February 14, 2014 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L2191-2E AWG4525EXNHN Refrigeration Range Design Pressure Low / High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size 10°F to 55°F 150 / 450 208-230V ~ 60HZ 187-254 16.27 30 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AWG5524EXN AW705ET-099-A2 60 11.73 OverLoad Replacement Kit - O/L Relay Replacement Kit - Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor Internal 820ARR3J50 K71-19 85PR370F17 35 MFD 370V 85PS330D76 88-108 MFD 330V 91017A Unit Drawing Wiring Diagram Wiring Diagram (A or F opt.) DGU1918-L103 WD21-2XT2 WD21-2AT2 AVAILABLE OPTIONS Fan Motor Replacement Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 50W230 2 0.7 51568-1 70831 70648-2 High Pressure Switch Low Pressure Control Dual Pressure Conrol 84095-1L 84026-2 Head Master Valve Check Valve Process Valve Discharge Valve (Base) Liquid Valve (Base) Liquid Valve (Receiver) Suction Valve (Base) Suction Valve (Rotolock) 70083-1 56626 31583-1 56618 56500-K06 attached 56500-K14 Condenser Receiver Accumulator Liquid Filter Sight Glass Suction Filter CrankCase Heater 50858-1 51099-2L TK00042000 70139 70084-S 70822-5S 91022-1 32Lxxxx-2ER(F)ATnD R Heated/Insulated Receiver F Fixed Fan Control A Adjustable Fan Control T1 Air Defrost Timer T2 Electrical Defrost Timer & Defrost Heater Contactor D Disconnect Switch (nonfused) AVAILABLE ACCESSORIES Solenoid Valve (supplied loose) KSVC-264 Hail Louver Assy LLPG-201 REPLACEMENT PARTS Receiver Heater (R option) 92124-2 Receiver Thermostat (R option) 84102-2 Fixed Fan Control (F option) 84132-01 Adjustable Fan Control (A option) 14955874 Defrost Timer (T1 or T2 option) Defrost Heater Contactor and Auxiliary Switch (T2 opt.) Disconnect (D option) 84110 91017A and 91017A-AUX