Download Tecumseh AVA2510ZXTHS Performance Data Sheet

Transcript
AVA2510ZXTHS_REV1
TPC - June 27, 2014
TECUMSEH OUTDOOR
CONDENSING UNIT
Model
BOM
Air Cooled
Application
Refrigerant
Volts-Hz-Ph
AVA2510ZXTHS
32L2117-2E*
2 ½ HP
Low Temp
R404A
200-230/60/3
28.94
27.35
27.94
26.55
25.50
23.50
26.08
2.96
SUCTION 7 8"
LIQUID 12"
AVA2510ZXTHS
Dim. Enclosure, inch (mm)
L
W
H
26.55 (674) 28.94 (735) 26.08 (662)
Line connections
Suction
Liquid
7/8"
1/2"
Pumpdown
90% @ 90oF
15.70
Air flow
SCFM
750
Oil Ch.
Oz.
54.9
Gross weight
Lbs. (kg)
250 (113)
Factory charge 20 psig dry air, MUST BE EVACUATED
Evaporator
T, °F
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
PSIG
5.5
8.0
10.7
14.0
17.1
19.3
24.5
28.8
33.5
36.5
43.7
BTUH
4400
5600
6800
8000
9200
10400
11600
12900
14100
15400
16700
80°F
Watts
1500
1710
1930
2150
2370
2600
2830
3070
3310
3550
3800
Cond T
93
95
98
101
104
107
110
114
117
121
125
BTUH
3700
4700
5800
6800
7800
8900
10000
11000
12100
13200
14200
Performance @ 60 Hz, Return gas 40oF , SubCooling 5oF
* OPTION CODE: See reverse side for Available Options
Ambient Temperatures
90°F
95°F
Watts Cond T BTUH Watts Cond T
1500
100
3300 1480
104
1690
103
4300 1670
107
1890
106
5300 1870
110
2100
109
6200 2080
113
2320
112
7200 2290
116
2550
115
8200 2520
119
2780
118
9200 2760
122
3030
122
10200 3010
126
3280
125
11100 3260
129
3540
129
12100 3530
133
3810
133
13100 3810
137
BTUH
3000
3900
4800
5700
6600
7500
8400
9300
10300
11200
12100
100°F
Watts Cond T
1460
109
1640
111
1840
114
2040
117
2260
120
2490
123
2730
126
2980
129
3250
133
3530
136
3810
140
BTUH
2200
3000
3900
4700
5500
6300
7100
7900
8600
9400
10200
110°F
Watts Cond T
1390
118
1570
120
1760
122
1960
125
2180
128
2420
130
2670
133
2940
136
3220
140
3520
143
3830
146
AVA2510ZXTHS_REV1
TPC - June 27, 2014
Parts/Specifications
STANDARD
Unit BOM
Unit MODEL
32L2117-2E
AVA2510ZXTHS
Refrigeration Range
Design Pressure Low / High
Volts - HZ - Ph
Voltage Range
Min. Circuit Ampacity
Max. Fuse Size
-40°F to 10°F
181 / 450
200-230V 3~ 60HZ
180 - 253
13.25
25
Compressor MODEL
Compressor BOM
Compressor LRA
Compressor RLA
AVA2490ZXT
AV182RT-012-A2Y
65.1
9.87
OverLoad
Replacement Kit - O/L
Relay
Replacement Kit - Relay
Run Capacitor
Run Capacitor Rating
Start Capacitor
Start Capacitor Rating
Contactor
Internal
Unit Drawing
Wiring Diagram
Wiring Diagram (A or F opt.)
DGU1920-L311
WD23-1T2B
91014B
AVAILABLE OPTIONS
Fan Motor
Replacement Fan Motor
Fan Motor Qty
Fan Motor RLA
Fan Blade
Fan Guard
Shroud
810F050C20
50W230
1
0.7
51568-1
70831
70727-2
High Pressure Switch
Low Pressure Control
Dual Pressure Conrol
84095-2L
84026-2
Head Master Valve
Check Valve
Process Valve
Discharge Valve (Base)
Liquid Valve (Base)
Liquid Valve (Receiver)
Suction Valve (Base)
Suction Valve (Rotolock)
70083
56626
AVAILABLE ACCESSORIES
Solenoid Valve (supplied loose)
KSVC-264
Hail Louver Assy
LLPG-101
56618
56500-K06
31590
56500-K10
31531-1
REPLACEMENT PARTS
Receiver Heater (R option)
92124-2
Receiver Thermostat (R option)
84102-2
Fixed Fan Control (F option)
Adjustable Fan Control (A option)
Condenser
Receiver
Accumulator
Liquid Filter
Sight Glass
Suction Filter
CrankCase Heater
50857-1
51082-1K
TK00042000
52000-084D
70084-S
70822-5S
90699
Defrost Timer (T1 or T2 option)
Defrost Heater Contactor and
Auxiliary Switch (T2 opt.)
84110
91014B and
91014-AUX
Disconnect (D option)
LDSG-301
32Lxxxx-2ER(F)ATnD
R Heated/Insulated Receiver
F Fixed Fan Control
A Adjustable Fan Control
T1 Air Defrost Timer
T2 Electrical Defrost Timer & Defrost
Heater Contactor
D Disconnect Switch (nonfused)