Download Tecumseh AVA4540EXNHN Performance Data Sheet
Transcript
TECUMSEH HERMETIC CONDENSING UNIT Model BOM Air Cooled Application Refrigerant AVA4540EXNHN TPC___rev 1 January 6, 2012 AVA4540EXNHN 32L3127-2E 3 HP High Temp R 22 36.25 35.25 26.08 23.50 26.43 3.00 0.50 4 PLACES MOUNTING HOLES AVA4540EXNHN SUCTION 7/8 Dimensions (inch) L W H 26.43 36.25 26.08 LIQUID 1/2 Line connections Suction Liquid 7/8 Sweat 1/2 Sweat Pumpdown o 90% @ 90 F 22.41 Air flow SCFM Oil Ch. Oz. Gross weight Lbs. 1550 55 280 Factory charge 20 psig dry air, MUST BE EVACUATED Evaporator o F 10 15 20 25 30 35 40 45 50 55 Psig 32.8 37.7 43.0 48.7 54.8 61.4 68.5 76.0 84.0 92.6 o BTUH 21400 24200 27100 30000 33000 36100 39300 42600 46000 49400 80 F Watts 2980 3160 3350 3560 3770 4000 4250 4500 4770 5050 o Cond T 100 102 105 108 111 114 118 121 125 128 BTUH 19600 22200 24900 27600 30500 33400 36300 39400 42500 45700 90 F Watts 3060 3260 3460 3680 3900 4140 4390 4650 4930 5210 Cond T 109 112 114 117 120 123 126 129 133 136 Ambient Temeratures o 95 F BTUH Watts Cond T 18400 3030 115 21000 3290 117 23600 3530 120 26300 3770 123 29000 4010 126 31800 4240 129 34700 4460 132 37600 4670 135 40600 4880 139 43600 5070 142 o BTUH 17300 19800 22400 25000 27700 30400 33100 35900 38800 41700 100 F Watts 3100 3310 3540 3780 4030 4290 4550 4830 5120 5410 o Cond T 119 121 124 127 129 132 135 138 141 144 L:\~ Andreea temp\~ DATA SHEETS\Outdoor Datasheets\WORD_Datasheets\High Temp Applications\AVA4540EXNHN_rev1.doc BTUH 15500 17900 20400 22800 25300 27800 30400 32900 35500 38100 110 F Watts 3130 3370 3610 3870 4140 4420 4710 5020 5330 5660 Cond T 128 130 133 136 138 141 144 147 150 153 06/01/2012 AVA4540EXNHN TPC___rev 1 January 6, 2012 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L3127-2E AVA4540EXNHN Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size (20°F to 55°F) 150 450 208-230V ~ 60HZ 187 - 253 28.05 50 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AVA5542EXN AV144ET-001-A2 108 21.15 OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL 820ARR3H46 85PR440F28 40 MFD, 440 V 85PS330D16 130-156 MFD, 330 V 91014 Unit Drawing Wiring Diagram DGU1920-L101 WD21-2XT2 OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 2 0.7 51568 70831 70648-2 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-1L 84026-D Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50858 70083-1 56626 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51099-2L 1 TK00042000 52000-084D SG-08DF 70822-5S CrankCase Heater 90699 Defrost Clock (Tn option) 84110 Defrost Heaters Contactor 91014 Rec. Heater (R option) Solenoid Valve (loose) LHR-222 KSVC-264 Disconnect (D option) LDSG-613 Wiring with A option WD21-2AT2 BOM INDEX DESCRIPTION 31529-1 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) NOTES IMPORTANT: FIELD INSTALLED SOLENOID & THERMOSTAT COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) ROOM THERMOSTAT Solenoid Valve 4 3 X DEFROST CONTROL RANCO 8145-xx PRECISION 6145-xx N 1 2 FAN 1 DEFROST HEATERS CONTACTOR COIL FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, AND L3 IN COMPRESSOR CONTACTOR (L1 AND L2 IF TWO POLE CONTACTOR) OR TO L1 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. PLACE JUMPER ACCROSS P1 AND L1 IN TERMINAL BOARD IF NO OTHER CONTROLLING DEVICE IS INSTALLED. 4. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL. FAN 2 GENERAL NOTES: COMPRESSOR CONTACTOR NC AUXILIARY SWITCH COMPRESSOR CONTACTOR COIL see note A HP A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. WITH ANY T.P.Co. APPROVED START RELAY USED, CONNECT LEADS TO SAME NUMBERED TERMINALS REGARDLESS OF LOCATION C. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. LP RECEIVER HEATER TERMINAL BOARD P1 L1 L2 L3 T1 T3 F1 F2 LP LOW PRESSURE CONTROL HEATER THERMOSTAT POWER SUPPLY 230-60-1 L3 T3 L2 T2 L1 T1 HP HIGH PRESSURE SWITCH FACTORY COMPONENTS POTENTIAL RELAY see note B GRD OPTIONAL FACTORY COMPONENTS COMPRESSOR CONTACTOR L1 L2 L3 L1 L2 L3 T1 T2 T3 T1 T2 T3 4 5 6 1 CONDENSING UNIT WIRING, 230V 60Hz 1 Ph, NO fan controls, T1 & T2 defrost options BLACK C S OPTIONAL FIELD COMPONENTS 2 DEFROST HEATERS CONTACTOR COMPRESSOR TERMINAL R START CAPACITOR WITH BLEEDER RESISTOR RED YELLOW BLACK RED YELLOW RUN CAPACITOR B REVISION NOV 06, 2009 CRANK CASE HEATER WD21-2XT2 L:\~ Andreea temp\~ DATA SHEETS\Outdoor Datasheets\WORD_Datasheets\High Temp Applications\AVA4540EXNHN_rev1.doc 06/01/2012