Download Taylor H62 User's Manual
Transcript
PROBLEM 5. The product is too soft. PROBABLE CAUSE PAGE REF. REMEDY a. Improper consistency control adjustment. a. Product should be dispensed at 27_ to 29_F. (-2.8_ to -1.7_C.). 13 b. The torque rotor is binding. b. Before installing the torque arm, check to see if the torque rotor can be rotated freely without binding. 23 c. Improper lubrication of torque rotor o-rings. c. Lubricate the o-rings properly. 24 d. Lubrication of torque rotor guide bearing. d. Do not lubricate the guide bearing. 23 e. Not enough air space around unit (air-cooled). e. Allow for adequate air flow across the condenser. 2 f. Dirty condenser (air-cooled) f. Clean regularly. 35 g. The mix is out-of-date. g. Use only fresh mix. 28 h. Loss of condenser cooling. h. Locate cause of water loss and correct. ------ 6. The mix in the hopper is too cold. a. The temperature is out of adjustment. a. Call a service technician to adjust hopper temperature. ------ 7. The mix in the hopper is too warm while in the AUTO mode. a. The hopper cover is not in position. a. Place the cover in position. b. The temperature is out of adjustment. b. Call a service technician to adjust hopper temperature. a. Mix and lubricant collected in the drive coupling. a. Brush-clean rear shell bearing area regularly. 35 b. Rounded corners of drive shaft, coupling, or both. b. Call service technician to correct cause and replace the necessary components. (Note: Do not lubricate end of drive shaft.) 22 8. The drive shaft is stuck in the gear box coupling. Models H62 & H63 39 28 ------ Troubleshooting Guide