Download Rinnai RCE-229A User's Manual

Transcript
HOME OWNER/INSTALLER
FOR YOUR SAFETY
THIS MANUAL MUST BE READ IN ITS
ENTIRETY BEFORE OPERATING HEATER
RCE-229A
SILENT SERVANT
CONVECTOR VENT-FREE SPACE HEATER
Owner’s Operation and Installation Manual
THIS IS AN UNVENTED GAS-FIRED HEATER. IT USES AIR (OXYGEN)
FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR
ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED.
REFER TO INSTALLATION INSTRUCTIONS ON PAGE 8.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING.
• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A
NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S
INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE
FIRE DEPARTMENT.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
INSTALLER: MUST LEAVE MANUAL WITH UNIT AFTER INSTALLATION.
OWNER: RETAIN THIS MANUAL SAFELY, FOR FUTURE REFERENCE.
T A B L E
O F
C O N T E N T S
Page
SPECIFICATIONS .................................................................................................3
SAFETY DEVICES ................................................................................................3
IMPORTANT POINTS ............................................................................................4
SAFETY POINTS ...................................................................................................5
USAGE AND INSTALLATION MUSTS ...................................................................7
INSTALLATION INSTRUCTIONS ..........................................................................8
OPERATING INSTRUCTION PLATE .....................................................................11
ADDITIONAL CUSTOMER OPERATING INFORMATION ..................................12
MAINTENANCE / SERVICE ................................................................................17
TROUBLE SHOOTING CHART ...........................................................................18
SCHEMATIC DRAWINGS/PARTS LIST ..............................................................................20
ERROR MESSAGES ...........................................................................................27
LIMITED WARRANTY .....................................................................................back cover
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER
TO THE OWNER’S INFORMATION MANUAL PROVIDED
WITH THIS APPLIANCE. INSTALLATION AND SERVICE
MUST BE PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER. FOR
ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS
SUPPLIER.
GENERAL INFORMATION
THIS SERIES IS DESIGN CERTIFIED BY THE AMERICAN GAS
ASSOCIATION LABORATORIES AS A VENT FREE CIRCULATOR AND
MUST BE INSTALLED ACCORDING TO THESE INSTRUCTIONS.
A N Y A LT E R AT I O N O F T H E O R I G I N A L D E S I G N I N S TA L L E D O T H E R
THAN AS SHOWN IN THESE INSTRUCTIONS OR USED WITH A TYPE OF GAS
NOT SHOWN ON THE RATING PLATE, IS THE RESPONSIBILITY OF THE PERSON
AND COMPANY MAKING THE CHANGE.
www.rinnaina.com
2
Model RCE-229A
S
P
E
C
I
F
I
C
Input Rating Input Rating
Thermostat
Btuh HIGH Btuh LOW
Model
RCE-229A-N
6,000
2,000
YES
RCE-229A-P
6,000
2,500
YES
“-N”
“-N”
“-P”
“-P”
A
T
I
O
Weight
in pounds
S
Dimensions
in inches
Height:
Width:
Depth:
13.4
N
Fan CFM
Output
14 9/16"
14 3/4"
6 11/16"
High: 64
Low: 46
Models are for Natural Gas. (Inlet Pressure within 4.3"-10.5"W.C.)
Models manifold pressure: 3.5"W.C.
Models are for L. P. Gas. (Inlet Pressure within 4.7"-13"W.C.)
Models manifold pressure: 4.4"W.C.
Gas connection pipe size 1/2" N.P.T. all models.
S
A
F
E
T
Y
D
E
V
I
C
E
S
„ Overheat Switch
When the heater gets too hot during operation (for example when the filters or air outlet louvers are
blocked) this device turns the gas off automatically. Remove cause of overheat (clean filters) allow
heater to cool, then re-ignite.
„ Fuse
The electrical circuits are protected by a fuse. When the fuse blows, the heaters will not operate at
all. The fuse must be replaced by an authorized person.
„ Flame Failure Device
This device automatically cuts off the gas supply to the heater in the event of a gas failure. To
restore the gas supply to the heater, turn it off, then follow the ignition procedure.
„ Oxygen Depletion Safety Device
If the oxygen level in the room drops below a pre-set limit, this device cuts the gas supply off to the
heater. If the oxygen depletion device operates, turn the heater off, ventilate the room, then follow the
ignition procedure to re-light. Heater will not re-light until room is fully ventilated.
„ Tilt Switch
If the heater is knocked over, the tilt switch will cut the gas supply off. The fan keeps running. To
restore the gas supply, stand the heater upright, turn it off then follow the ignition procedure. The
tilt switch may also operate if the heater is jolted or picked up while in operation.
„ Power Failure
In the event of a power failure or power cut, the gas valves will automatically close. After the
power is re-instated the appliance must be restarted manually.
Model RCE-229A
3
800-621-9419
I
M
P
O
R
T A
N
T
P
O
I
N
T
S
UNPACK HEATER:
Check for damage. (DO NOT INSTALL DAMAGED HEATER.) If heater is damaged, contact your
supplier for advice. Before installing a heater, check the label for the correct gas type (see label on side
of heater).
Refer to local gas authority for confirmation of gas type if you are in doubt.
INCLUDED IN CARTON:
Customers Operating Information/Manual Gas Valve
IMPORTANT
1. The appliance must be installed in accordance with state and local codes.
2. For information on gas rate, see data plate on the appliance.
3. When using this appliance, ensure that the room is correctly ventilated. Check the local gas
authority for information on ventilation requirements.
4. The heater must not be installed where curtains or other combustible materials could come into
contact with it. In some cases, curtains may need restraining. It must also be 2" (50mm) clear of
walls.
5. This appliance is not designed to be built in.
6. If you move, check the gas type in the area where you are moving to. The local gas authority will
be able to advise on local regulations.
7. This heater discharges a large volume of warm air at low level to provide even heat distribution. If
the air in the room contains cooking vapor or cigarette smoke, and the heater is used on a carpet,
the surface of the carpet may become discolored.
In addition, some nylon carpets contain dyes which may be affected by the warm air flow. Some
soft vinyl surfaces are also subject to distortion, or discoloration by warm air. To prevent
discoloration of carpets etc., a mat should be placed under the appliance, extending about
30"(750mm) in front of it.
8. This heater can be installed in a bathroom or a bedroom.
When installed in a bathroom or a bedroom, the heater must be wall mounted with optional wall
mounting kit.
See page 26 of manual for part No. of wall mounting kit.
www.rinnaina.com
4
Model RCE-229A
S
A
F
E
T
Y
P
O
I
N
T
S
Do not install this heater in areas where
spray painting or plating is taking place, or
in places such as hair dressers, where there
may be a lot of fluff and dust, and where
aerosols are used. May create strong odors
and irritate eyes and sinuses.
Do not move the heater while it is turned on.
Do not spray aerosols near this heater while
it is in use. Many aerosols contain butane
gas and can be a fire hazard. Use of
aerosols, paint, polishes etc., while this
heater is in use will cause unpleasant smells.
Turn off heater when not in use and when
away for long periods of time.
Do not allow children or elderly persons to
sleep in the warm air discharge from the
heater.
Do not sit on this heater.
Model RCE-229A
5
800-621-9419
S
A
F
E
T
Y
P
O
I
N
T
S
Do not place wet articles on this heater, the
water may drip into the electrical parts.
Do not allow children to put articles in the
louvers.
Supervise children playing near this heater.
Do not turn the heater off by unplugging it
from the wall, or while the fan is cooling the
heater off. (This heater is not suitable for
use with a plug in type timer.)
Ventilate the room when this heater is in
use. Correct, fixed ventilation is usually
sufficient, consult your local gas authority
for local regulations.
Keep away from flammable materials.
Combustible materials must not be placed
where the heater could ignite them.
Do not place articles in front of the hot air
discharge.
Do not place containers of liquid on top of
the heater. Water in the heater can cause
extensive damage.
www.rinnaina.com
6
Model RCE-229A
U S A G E A N D I N S TA L L AT I O N M U S T S
1.
Read these rules and the instructions carefully. Check all local codes. Failure to follow these could cause a
malfunction of the heater resulting in death, serious bodily injury and/or property damage.
2.
This heater is designed for use only with one type of gas, either L.P.G. or Natural Gas. Make sure that the type of
gas to be supplied to this unit matches that shown on the rating plate on the heater. This unit is not convertible.
3.
WARNING: Any change to this heater or its controls can be dangerous.
4.
If a gas leak is suspected, turn heater off, turn gas supply valve off at regulator or appliance connecter valve. Open
windows to ventilate area immediately and contact your dealer or gas company.
5.
Installation and repair should be done by a qualified service person. Heater should be inspected before use and at
least annually by a professional service person. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc. It is imperative that control compartment, burners and circulating air passageways
be kept clean.
6.
Keep area near the heater clear and free from combustible materials, gasoline and other flammable vapors and
liquids.
7.
Due to its high temperature, the heater should be located out of traffic and away from furniture and draperies.
8.
Do not place clothing or flammable material on or near the heater.
9.
Any safety panel or guard removed for servicing must be replaced prior to operating the heater.
10.
An unvented gas heater will increase the amount of humidity in the room.
11.
This heater is intended for space heating purposes only. Do not use for other purposes such as drying clothes or
baking paints.
12.
Do not touch the outlet area while the heater is in use. To avoid burns, do not move the heater during use and
avoid touching the heater just after turning off.
13.
Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid
burns or clothing ignition.
14.
Young children should be carefully supervised when they are in the same room with the heater.
15.
L.P.G containers must not be installed indoors.
16.
Do not install in a windy area such as facing a window or a door leading to the outside.
17.
Do not use this room heater if any part has been under water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the control system and any gas control which has been under
water.
18.
Carpet lint or cigarette smoke may pass through the heater, discolor, and be deposited into the room.
19.
This unit discharges a large volume of warm air at a low level to provide even heat distribution. If the air in the
room contains cooking vapors, cigarette smoke, and if used on carpet, the surface in front of unit is subject to
discoloration. Some carpets contain dyes which can be effected by warm air flow and could discolor. To aid in
prevention of discoloration, place a mat under the unit to extend to the front 30 “.
Model RCE-229A
7
800-621-9419
I N S TA L L AT I O N
I N S T R U C T I O N S
NOTICE BEFORE INSTALLATION
The heater must be installed by a qualified service person according to this installation instructions.
When used without adequate combustion and ventilation heater air may give off carbon monoxide.
Check your local building codes for the proper method of installation. In the absence of local codes, this heater
installation must conform with American National Standard (National Fuel Gas Code) ANSI Z223.1.
Available from the American National Standards Institute, Inc.,
1430 Broadway, New York, NY 10018, or from the National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
All correspondence should refer to Model No., Serial No., and type of gas.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle.
This appliance may be installed in an aftermarket manufactured (mobile) home where not prohibited by state or
local code.
Aftermarket = completion of sale, not for purpose of resale from manufacturer.
This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided
for adequate combustion and ventilation air.
The National Fuel Gas Code ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic
feet per 1,000 Btu per hour (4.8m3 per kW) of the aggregate input rating of all appliances installed in that space and
an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kW)
of the aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
The following formula can be used to determine the
maximum heater rating per the definition of unconfined
space:
BTU/HR = (L1 +L2)Ft X (W)Ft X (H) Ft X 1000
50
Consider two connecting rooms with an open area
between, with the following dimensions:
BTU/HR = (15 1/2+12) X (12) X (8) X 1000
50
= 52800 BTU/HR
If there is a door between the two rooms that can be
closed the calculation must be based only on the room
with the heater.
BTU/HR = (15 1/2) X (12) X (8) X 1000
50
= 29760 BTU/HR
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if
the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the
methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable local codes.
www.rinnaina.com
8
Model RCE-229A
I N S TA L L AT I O N
I N S T R U C T I O N S
Unusually tight construction is defined as construction where:
a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a
rating of 1 perm (6X10-11kg per pa-sec-m2) or less with openings gasketed or sealed, and
b) Weather stripping has been added on openable windows and doors, and
c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole
plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing,
electrical, and gas lines, and at other openings.
LOCATION AND CLEARANCES
1. The minimum clearances from the combustible materials areas follows:
2 inches from top
2 inches from back
2 inches from side
30 inches from front
0 inches from bottom
2. This heater may be installed on combustible flooring. When the heater is installed directly on carpeting,
tile or other combustible material other than wood flooring, the heater shall be installed on a metal or
wood panel extending the full width and depth of the heater.
3. Adequate clearances for accessibility for purposes of servicing and proper operation must be provided.
4. Adequate clearances around air openings must be provided.
5. Right and left sides are determined when facing the front.
6. Do not install in areas where curtains, drapes, clothing, or other moving flammables are within 12 inches
of this unit.
7. This unit is designed to mount directly to a wall with optional wall mounting kit. See page 24 for part No.
of wall mounting kit.
8. Make certain of adequate combustion and ventilation air.
9. Do not oversize the heater to the room.
GAS CONNECTION
1. The gas supply line shall be gas-tight, sized and so installed as to provide a supply of gas sufficient to
meet the maximum demand of the heater without loss of pressure.
2. A shut off valve (or appliance connector valve) should be installed in the upstream of the gas line to
permit servicing.
3. Flexible pipe and any appliance connector valve used for gas piping shall be types approved by
nationally recognized agencies.
Model RCE-229A
9
800-621-9419
I N S TA L L AT I O N
I N S T R U C T I O N S
4.
Any compound used on the threaded joint of gas piping shall be a type which resists the action of
liquefied petroleum gas.
5.
Supplied gas pressure must be within the limits shown in the specifications.
6.
After completion of gas pipe connections, all joints including the heater must be checked for
gas-tightness by means of leak detector solution, soap and water, or an equivalent nonflammable
solution, as applicable.
CAUTION: Since some leak test solutions, including soap and water, may cause corrosion
or stress cracking, the piping shall be rinsed with water after testing, unless it has been
determined that the leak test solution is noncorrosive.
7
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi
(3.5kPa).
8.
A valve supplied must be installed on back of unit at time of installation. This is for compliance to ANSI
standard Z21.11.2. Valve is packaged with unit.
MANUAL VALVE
CLOSED
9.
OPEN
After completing pipework, secure the heater to the floor. Use the two screws provided, as shown in
the drawing. To prevent deforming base plate, do not over torque screws.
www.rinnaina.com
1 0
Model RCE-229A
I N S TA L L AT I O N
I N S T R U C T I O N S
OPERATING INSTRUCTION PLATE
CONVECTOR RCE-229A
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
A.
This appliance does not have a pilot. It is equipped
with an ignition device which automatically lights the
burner. Do not try to light the burner by hand.
B.
BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on
the floor.
•
If you cannot reach your gas supplier, call the fire
department.
C.
Use only your finger to push with. Never use tools. If the
button will not reactivate by touch, don’t try to repair it,
call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
WHAT TO DO IF YOU SMELL GAS.
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any
phone in your building.
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
OPERATING INSTRUCTIONS
•
1.
2.
3.
STOP! Read the safety information above on this
label. This appliance is equipped with an ignition
device which automatically lights the burner. Do not try
to light the burner by hand.
Turn off all electric power to the appliance via
the ON/OFF button on the control panel. Locate manual
gas valve to be found on back side of heater.
Turn Manual valve clockwise
to the full OFF
position.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you then smell gas, STOP!
Follow “B” in the safety information above on
4.
5.
6.
7.
8.
9.
10.
this label. If you don’t smell gas, go to next step.
Turn Manual gas valve to the full ON position.
Turn on all electric power to the appliance.
Press ON/OFF button to “ON”.
Set the thermostat to desired setting.
Burner is lit when operation lamp glows red.
If operation lamp is flashing red, burner has not been lit.
If the appliance will not operate, follow the instructions
“To turn off gas to appliance” and call your service
technician or gas supplier.
Room Temperature
Display
Filter Warning Lamp
MANUAL VALVE
CLOSED
OPEN
Temperature
Down
Temperature
Up
Function
Lock
Ignition
Button
TO TURN OFF GAS TO APPLIANCE
1.
2.
Turn off electric power to the appliance using the ON/
OFF switch located on the control panel.
Turn manual valve clockwise
to the full OFF
position.
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause personal injury or loss
of life. Refer to the owner’s information manual provided
with this appliance. Installation and service must be
performed by a qualified installer, service agency or the
gas supplier.
NOTE: The fan will continue to operate until the
appliance is cool, do not turn the appliance off by
unplugging it from the wall. Keep burner and control
compartment clean. See installation and operating
instructions accompanying heater.
Model RCE-229A
1 1
800-621-9419
ADDITIONAL CUSTOMER OPERATING INFORMATION
INSTALLATION
Make certain the heater is connected intoboth
the gas and the electric power.
Check room size and ventilation. Do not
oversize. Improper sizing may cause
nuisance lock outs.
CONTROL PANEL LAYOUT
ON TIMER INDICATOR
TIME/TEMP DISPLAY
Indicates that the ON Timer
mode is in operation.
Shows either the
temperatures or coded error
messages.
FILTER INDICATOR
Indicates that the filter
needs cleaning.
AUTO-OFF INDICATOR
Indicates the thermostat-off
function is activated.
COMBUSTION INDICATOR
Indicates that the burner is
alight and the appliance is
heating the room.
INDICATORS
OFF TIMER INDICATOR
ECONOMY INDICATOR
Indicate what information is
currently displayed on the
LED display.
Indicates that the OFF
Timer mode is in operation.
Indicates that the
Economy mode is in
operation.
OFF TIMER BUTTON
TIME/TEMP ADJUSTMENT
S e l e c ts o p e r a t i n g m o d e
f o r d e l a y O F F Ti m e r
function.
Increases or decreases the
temperature setting as well as
changing hours or minutes.
AUTO-OFF BUTTON
Selects the thermostat-off
function.
www.rinnaina.com
ON/OFF BUTTON
Main switch for turning
O N / O F F.
ON TIMER BUTTON
Selects operating
mode for delay ON Timer
function.
FUNCTION LOCK INDICATOR
Indicates Function lock
is activated.
1 2
FUNCTION LOCK
Locks all controls when
pressed. (Except OFF)
Model RCE-229A
O P E R AT I N G Y O U R N E W R C E - 2 2 9 A
„
TURNING ON
Press the ON/OFF button to operate the heater. The ON
indicator will glow green. After approximately 20 seconds
the spark generator will be heard before the burner ignites
and the ON indicator glows red, indicating that the burner
is alight. Warm air can be felt coming from the louvres 15
seconds later.
If the heater does not ignite on initial use, this may be due to air remaining in the gas supply
line. The spark generator will only continue for 15 seconds. After this it will be necessary to
press the ON/OFF button OFF, then ON again.
„
TURNING OFF
Simply press the ON/OFF button to switch off the heater.
The ON indicator will go out. The convection fan will
continue to operate for several minutes after the burner has
gone out in order to cool the appliance. Do not unplug the
appliance while the convection fan is running.
DO NOT turn heater off by unplugging at the power point.
The convection fan will continue to run until the appliance cools.
„
ROOM TEMPERATURE ADJUSTMENT
The room temperature and pre-set temperatures can only be displayed and adjusted when
the heater is running.
Press the “S” button to increase the temperature setting
or “T” button to decrease the temperature setting.
The temperatures can be preset to:
a)
[L] low (about 50°F)
b)
[60°F] to [80°F] in 2°F increments
c)
[H] (continuously high)
If the heater does not ignite then the pre-set temperature may not be set to a setting which
is higher than the actual room temperature.
„
AUTO-OFF FUNCTION
When you select AUTO-OFF, the indicator light
will glow. You have selected a Full Thermostat
Control Function. The heater will cycle High, Low
and OFF to maintain the selected room
temperatures.
When the AUTO-OFF indicator is not glowing,
you have selected a manual off mode of
operation. The unit will continue to produce at
least 2000 BTU/h of heat until you cut the unit off
manually.
Model RCE-229A
13
800-621-9419
OPERATING YOUR NEW RCE-229A
„
ECONOMY MODE
The Economy mode only operates when the heater is turned on. The Economy mode
operates automatically.
The Economy indicator will glow to show that the
Economy function is activated.
After the room is heated initially the air temperature may
be dropped to a lower level without affecting comfort. 30
minutes after the selected room temperature (set with the
thermostat) is reached, the Economy mode, if set,
reduces the temperature by 2°F. After another 30 minutes
it reduces the temperature by a further 2°F, this is an
energy saving feature. The Economy mode does not
operate if the heater is under capacity for the room size.
„
FUNCTION LOCK
The Function Lock will help to prevent accidental operation as well as small children from
altering the controls.
To operate the Function Lock simply press the Lock
button. The function is activated immediately and the
Function Lock indicator will glow.
To deactivate the Function Lock simply press the Lock
button for 2 seconds and the Function Lock indicator will
go out. The lock can be deactivated at any time in this
way.
During normal operation the Function Lock may be activated and all controls other than the
OFF switch will be locked. Deactivating the lock releases the controls. If the lock is
activated while the heater is turned OFF, then all functions will be locked. If the heater is
turned OFF while the Function Lock is activated, it cannot be turned ON again until the lock
is deactivated.
www.rinnaina.com
1 4
Model RCE-229A
T
„
I
M
E
R
O
P
E
R
A
T
I
O
N
OFF TIMER OPERATION
This feature is useful on cold nights when the unit continues to operate after you have gone to
bed.
The OFF Timer can be selected when the heater is operating manually, in OFF, or in ON Timer mode.
When the OFF Timer feature is selected, the heater will automatically switch off after 60 minutes.
1
Press the OFF Timer button. The OFF Timer
indicator lights up.
The heater will operate at the preset temperature selected in the system memory.
The temperature will automatically run at 80°F if the set temperature is “H”.
If selected while the ON Timer is set, the heater will come on and run for 60 minutes, after which it will
remain in ON Timer standby mode.
If the ON Timer is selected after the OFF Timer has been selected, the unit will run for 60 minutes (OFF
Timer mode ) and then remain in the ON Timer standby mode.
In all cases where the ON and OFF Timers are selected together, the OFF Timer will take precedence and
run the heater for 60 minutes after which the heater will remain in the ON Timer standby mode.
OFF TIMER STOPS AFTER 1 HOUR.
Five minutes before the finish of the OFF Timer, the OFF Timer indicator will flash, indicating that the function is
nearing completion.
The OFF Timer indicator will then go out at completion of the 60 minute time delay.
In cases where both the ON and OFF Timers are selected, once the OFF Timer has run the heater for 60 minutes,
the ON Timer indicator will remain alight and the heater will be in ON Timer standby mode.
To cancel the OFF Timer, press either the ON-OFF button or the OFF Timer button at any time.
„
ON TIMER OPERATION
The ON Timer allows you to program the heater to turn on after a pre-determined time period.
As an example, if the time now is 10:30 pm and you wish the heater to start at 6:00 am tomorrow morning, then the
ON Timer must be set to 7.5(hours).
The ON Timer preset times are from 30 minutes to 24 hours.
These times can be selected in 30 minute increments up to 10 hours and then 1 hour increments up to the maximum
of 24 hours.
BEFORE SELECTING THE ON TIMER CONFIRM:
That the desired preset room temperature has been set (see page 13)
Model RCE-229A
15
800-621-9419
T
I
M
E
R
O
P
E
R
A
T
I
O
N
WARNING
y
y
1
Ensure there are no obstacles or foreign materials directly in front of the appliance where
the warm air will discharge into the room.
Ensure the appliance is not positioned where warm air discharge will blow directly on
someone sleeping.
Press the “ON Timer” button
The “ON Timer” and “ON/Combustion” (green) indicators
will light up.
A preset time will be displayed on the digital monitor.(The
first time the ON Timer is preset, this time will be “8.0”)
The ON Timer can be selected while the unit is in
operation, or while it is off (if set during operation,
pressing the ON Timer button will stop the unit heating and the ON/Combustion indicator will
change from red to green). The appliance will remain in standby mode.
2
Presetting the time
Pressing the “T” or “S” buttons alters the preset time. After
10 seconds the digital monitor will go out.
If the display has gone out:
Pressing the “T” or “S” buttons once will show the remaining
time on the digital monitor.
Pressing the button more than once will alter the preset time.
3
The heater will operate after reaching the end of the preset time.
“ON/Combustion” Indicator glows red.
The heater will operate at the preset temperature selected in the system memory.
The heater will automatically operate at 80°F if the preset temperature is set to “H”.
4
The heater stops automatically after 1 hour.
The”ON Timer” indicator will flash to indicate that heating is about to stop (at approximately 55 minutes).
After another 5 minutes the heater will automatically stop heating and turn off completely.
The “ON Timer” indicator will continue to flash until the heater is manually operated again. The “ON/
Combustion” indicator will go out.
Pressing the ON-OFF button will turn off the ON Timer indicator.
TO CANCEL THE ON TIMER
Press the “ON Timer” button or press the “ON-OFF” button.
The setting will be cancelled and the timer indicators will go out.
The ON Timer will be cancelled if the power plug is removed from the power point, a power failure while
the appliance was in standby mode, or if the ON Timer setting is cancelled. “00” will flash on the digital
monitor when power is reinstated. Pressing the ON button and starting the unit will delete the “00”.
www.rinnaina.com
1 6
Model RCE-229A
M A I N T E N A N C E / S E R V I C E
MAINTENANCE SUGGESTIONS
This heater has been designed and constructed for a long performance life when installed and operated
properly under normal conditions. Regular inspections, as outlined in this section, are strongly
recommended as means of keeping your heater operating efficiently and safely throughout the season.
Access to internal parts is from the front of the heater.
1.
Cleaning
Clean air filter at least once a week. Do not wait for filter
warning lamp to come on before cleaning filter. Do not use
the heater with the filter warning lamp on, this may cause it
to overheat. Dusty filter reduces the air flow through the
heater, as well as, reducing the heater’s effectiveness. Clean
filter with air pressure or vacuum cleaner.
Heater must be cleaned annually. Keep heater clear of dust and debris especially in and around
the ODS burner. Cleaning procedures of heater are as follows:
1) Turn heater off. Unplug electric cord and allow to cool for one hour.
2) Remove the two(2) screws that hold the louver and two(2) screws at the bottom of the left and
right hand side panel.
3) Use pressurized air to remove dust from around
burner and electrical components.
Apply air pressure with nozzle to five(5) holes on
combustion chamber cover.
(See page 24 of schematics, part #RC-219-31, key
#117-1)
4) All outside parts of the heater can be cleaned using
soap and water on a soft damp cloth.
DO NOT DAMAGE OR DISTORT ANY PARTS OF HEATER.
DO NOT USE WET CLOTH OR SPRAY CLEANERS ON BURNER.
UNIT SHOULD BE CHECKED AND CLEANED ANNUALLY BY A PROFESSIONAL.
TROUBLE SHOOTING
STEP 1:
1)
Be sure the heater is properly installed. See Section 2. INSTALLATION.
2)
Make sure gas valve on L.P. Gas bottle or gas supply line is ON and gas pressure is available.
3)
Make a careful visual inspection of all electrical connection and wiring.
STEP 2:
If the trouble persists after checking step 1, please check the cause of trouble in the following trouble shooting
chart and correct it by following the procedures shown.
Model RCE-229A
1 7
800-621-9419
T R O U B L E S H O O T I N G
C H A R T
Ɣ
Power Cut
Ɣ
Ɣ
(Initial Installation)
Air in Gas Pipe
Smell of Gas
Ɣ
Combustion Stops During
Operation
Burner Doesn't Ignite
Not Plugged In
Cause
Filter Warning Lamp Glows
No ON Indicator
Problem
Takes too Long to Warm the
Room
Please note: General cleaning, maintenance and wear and tear are not necessarily covered under the
guarantee. Calls of this nature may be chargeable.
Plug In
Re-Ignite manually after power is
restored
Ɣ
Ɣ
Purge air (installer)
Ɣ
Room too Large
Ɣ
Dust on the Air Filter
Remedy
Check with retailer
Clean the air filter (weekly)
Louver Obstructed
Ɣ
Ɣ
Clean obstruction
Air Filter Blocked
Ɣ
Ɣ
Clean filter (weekly)
Ɣ
Gas Escape
Service call
ON Timer is Set
Ɣ
Cancel ON Timer
Function Lock Set
Ɣ
Cancel Function Lock
Ɣ
Turn gas on
Gas Turned Off at Meter
www.rinnaina.com
Ɣ
1 8
Model RCE-229A
Model RCE-229A
19
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your protection against
shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG!
If any of the original wire as supplied with the appliance must be replaced, it must be
replaced with a wire of at least a 194°F temperature rating.
CAUTION: Label all wires prior to disconnecting when servicing controls. Wire errors can
cause improper and dangerous operation. Verify proper operation after servicing.
S C H E M A T I C
D R A W I N G S
Wiring Diagram
800-621-9419
S C H E M A T I C
D R A W I N G S
Cabinet - Exploded View
www.rinnaina.com
20
Model RCE-229A
S C H E M A T I C
D R A W I N G S
Gas Valve/Burner Assembly - Exploded View
Model RCE-229A
2 1
800-621-9419
S C H E M A T I C
D R A W I N G S
Fan Blower Assembly - Exploded View
www.rinnaina.com
22
Model RCE-229A
S C H E M A T I C
D R A W I N G S
Electrical Wiring - Exploded View
Model RCE-229A
23
800-621-9419
P A
001
002
003
004
005
006
007
008
009
100
No.
001-1
001-2
001-3
005-1
005-2
007-1
007-2
009-1
009-2
100-1
100-2
101
102
103
104
105
104-1
104-2
105-1
105-2
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
107-1
107-1
107-2
112-1
112-2
112-3
113-1
113-2
115-1
115-2
117-1
117-2
118-1
118-2
R
T
S
PART NAME
FRONT PANEL I
SCREW
SCREW
LOUVER ASS'Y
REAR PANEL G
TC CHECK HOLDER
TOP PLATE
SCREW
AIR FILTER
TOP PLATE COVER
SCREW
TOP PLATE COVER SHEET
BASE
SCREW
SECONDARY AIR COVER
SCREW
BURNER ASS’Y
BURNER ASS'Y
GAS CONTROL ASS'Y
O-RING
CONNECTION PIPE ASS'Y
SCREW
INJECTOR HOLDER
SCREW
INJECTOR
INJECTOR
DAMPER
DAMPER
SCREW
O-RING
BLIND SCREW
PACKING
FILTER
GAS INLET FLANGE
SCREW
SCREW
BURNER LID
SCREW
ELECTRODE
ELECTRODE BRACKET
SCREW
SILICON TUBE
COMBUSTION CHAMBER COVER
SCREW
COMBUSTION CHAMBER COVER LID
SCREW
HEAT SHIELD
SEPARATION BOARD
www.rinnaina.com
24
L
I
S
T
PART No.
RC-219-50-9
ZFAB0410SC
ZFAB0408SC
RC-219-46-5
RC-219-42-7
RC-334-73-1
RC-229-516-SP
ZFAB0410SC
RC-219-29
RC-219-52
CP-30486-2
RC-219-56
RC-219-41-5
ZFAB0410SZ
RC-219-38
CP-30518-1
B6C1-1-1
B6C1-1-2
C36D-3-6-S
M10B-1-10
RC-229-512
ZHAA0406SZ
RC-208-22
ZFAB0410SZ
RC-208-11-2-1.20
RC-208-11-1-0.90
RC-208-23-20
RC-208-23-19
ZFAB0408SZ
M10B-13-14
AU39-965
C3I1-7
RCK-6808
431F-1110-2
ZHAA0412SZ
ZBA0408SC
RC-219-39
ZFAB0408SZ
RC-328-32-2
RC-334-136
ZFAB0408SZ
RC-223-84-b
RC-219-31
ZFAB0408SZ
RC-352-29
ZFAB0408SZ
RC-219-35
RC-219-37
QTY.
1
2
2
1
1
1
1
4
1
1
2
1
1
5
1
4
1
1
1
2
1
2
1
2
1
1
1
1
1
1
1
1
1
1
2
4
1
1
1
1
2
1
1
6
1
1
1
1
REMARKS
NG
LPG
NG
LPG
NG
LPG
Model RCE-229A
P A
121
No.
121-1
121-2
121-3
122
123
124
125
126
128
131
132
134
135
136
137
138
139
140
141
142
143
144
123-1
123-2
125-1
125-2
128-1
128-2
134-1
134-2
135-1
135-2
137-1
137-2
138-1
138-2
140-1
140-2
142-1
142-2
143-1
143-2
143-3
144-1
144-2
700
701
702
703
700-1
700-2
700-3
700-4
700-5
700-6
701-1
701-2
701-3
703-1
703-2
R
T
S
PART NAME
COMBUSTION CHAMBER ASS'Y
SCREW
SCREW
TC SPACER
TC SPACER
THERMOCOUPLE BRACKET
SCREW
THERMOCOUPLE TOTAL ASS'Y
THERMOCOUPLE FIXER
SCREW
CONVECTION FAN
BEARING
SCREW
CLAMP
NYLON TACK
SUB P.C.B. BRACKET
SCREW
POWER SUPPLY CABLE BRACKET
SCREW
VALVE COVER
CONNECTION PIPE FIXER
SCREW
OVER HEAT SWITCH
SCREW
CIRCUIT BOARD SPACER
OUTLET
SCREW
CABLE CLIP
THERMISTOR HOLDER
SCREW
CONVECTION FAN TOTAL ASS'Y
SCREW
SCREW
PLATE HOLDER
SCREW
P.C.B. ASS'Y
P.C.B.
P.C.B. FIXER
SCREW
SCREW
IGNITER ASS'Y
SCREW
SUB P.C.B.
CURRENT FUSE
SCREW
TF HARNESS
POWER SUPPLY CORD
SCREW
Model RCE-229A
L
I
S
PART No.
RC-219-30
ZFAB0408SZ
ZFAB0408SC
RC-209-68-1
RC-209-68-2
RC-152-224
CP-30523-2
RC-511-66-1
RC-210-89-2
ZFAB0406SZ
RC-229-13
RC-223-74
ZFAB0406SZ
CP-90312
RC-215-24-1
RC-229-1013
ZFAB040BSZ
RC-329-1033
ZFDB0408SB
RC-606-96
RC-208-21
ZFAB0408SZ
ES-01183
CP-30518-1
CP-90436-3
RC-229-511
ZHAA0412SZ
CP-90125-2
RC-229-540
ZFAB0408SB
RC-229-523
ZFAB0408SC
ZFAB0408SZ
RC-229-539
ZFDB0410SB
RC-229-514
ED-247-V1
RC-229-513
ZGAA0308SZ
ZFAB0410SZ
EI-181-1
CP-30421-1
ED-189
EP-102-13
CP-30421-1
RC-229-530
CP-90466-1
CP-30421-1
25
T
QTY.
1
2
2
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
4
1
2
2
1
1
1
4
2
2
2
1
1
1
4
1
1
1
1
1
1
1
1
1
REMARKS
NG, LPG
LPG
250V 3A
800-621-9419
P A
R
T
S
L
I
S
802
803
804
901
902
903
PART NAME
CONVECTION FAN MOTOR ASS'Y
THERMISTOR
TC CHECK LEAD WIRE
MVIG HARNESS
TRANSFORMER
SCREW
OVER HEAT THERMISTOR
SCREW
OPERATION P.C.B.
SCREW
OWNER'S INFORMATION MANUAL
RATING PLATE
RATING PLATE
CAUTION PLATE
OPERATING PLATE
WIRING DIAGRAM
ANCHOR
SCREW
MANUAL VALVE ASS'Y
PART No.
RC-229-524
RC-511-65-3
RC-606-11-1
RC-229-529
ET-250
ZFAB0408SZ
RC-241-70
ZFAB0408SZ
RC-229-517
ZGAA0308SZ
RC-229-521
RC-229-527-1
RC-229-527-2
RC-229-525
RC-229-538
RC-229-520
AU 102-902
CP-30408
BRR37-244
904
WALL BRACKET KIT (OPTION)
RC-229-550
No.
704
705
706
707
709
710
711
800
801
709-1
709-2
710-1
710-2
711-1
711-2
www.rinnaina.com
26
T
QTY. REMARKS
1
1
1
1
1
1
1
1
1
5
1
1 NG
1 LPG
1
1
1
2
2
1
1
Model RCE-229A
E
R
R
O
R
M
E
S
S
A
G
E
S
This heater has the ability to check its own operation continuously. If a fault occurs, an Error Message will flash on
the Digital Display of the control panel. This assists with diagnosing the fault, and may enable you to overcome a
problem without a service call. Please quote the code displayed when inquiring about service.
CODE DISPLAYED
FAULT
Tilt Switch Activated
REMEDY
Turn heater ON,
after setting heater upright.
Miss Ignition
Check gas is turned ON.
Service call if repeated.
Flame Failure
Ventilate the room.
Service call if repeated.
Back Fire Sensor Activated
Overheat
Room Overheat
Power cut
Turn heater OFF, after a while ON
again. Service call if repeated.
Clean filter.
Service call if repeated.
Service call.
Turn heater OFF,
then ON again.
If you see other codes displayed, contact Rinnai or your nearest service agent and arrange for a service
call.
In all cases, you may be able to clear the Error Message simply by turning
the heater OFF, then ON again. If the Error Message still remains or returns
on the next operation, contact RInnai or your nearest service agent and
arrange for a service call.
27
LIMITED WARRANTY
RINNAI SPACE HEATERS
Rinnai America Corporation warrants the products described in this warranty including any parts and components thereof, to be free from any
defects in materials and workmanship for the period specified below, subject to the terms specified in this warranty. This warranty gives you
specific legal rights and you may also have other rights which vary from state to state. This warranty extends to the original purchaser.
MODEL
PERIOD OF COVERAGE
TYPE OF FAILURE COVFRFD
SILENT SERVANT
RCE-229A
THREE YEARS FROM
DATE OF PURCHASE
DEFECTIVE MATERIALS
AND WORKMANSHIP
In the event of a malfunction, operational difficulty or failure of the product, or any parts or components, during the warranty term, resulting from
defects in materials of workmanship Rinnai will remedy the malfunction, operational difficulty, or failure without charge to the owner. The remedy
will consist of repair or replacement of the product (including payment of reasonable shipping costs) at the option of Rinnai. You may obtain the
benefits of warranty coverage by returning the product to a qualified Rinnai servicing agent which has been qualified by Rinnai or its authorized
distributor. Any such warranty replacement or repair shall be subject to the terms and conditions of this warranty for the remainder of the original
period of coverage. In order to obtain the name and location of the qualified Rinnai servicing agent closest to you, please write Rinnai at the
address shown on the back side of the warranty card or call Rinnai at 1-800-621-9419.
This warranty does not cover any failure, operational difficulty, or malfunction due to accident, abuse, misuse, alteration, Acts of God, misapplication,
improper installation or improper maintenance or service, or from any cause other than defects in materials and workmanship.
Any implied warranties of merchantability and fitness applicable to the equipment are limited in duration to the period of coverage of this express
written warranty. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you.
Rinnai is not liable for any special, indirect or consequential damages; some states do not allow the exclusion or limitation of incidental or
consequential damages, so this limitation may not apply to you.
Rinnai does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, application,
engineering, installation, use, removal, return, or replacement of its products; and no such representatives are binding on Rinnai. The
Warranty Registration Card provided below should be returned within two weeks of purchase to help Rinnai better serve you. However, the return
of the Registration Card is not necessary in order to validate this warranty.
EXTENDED WARRANTIES ARE AVAILABLE,CONTACT RINNAI FOR DETAILS.
SPACE HEATER
WARRANTY REGISTRATION CARD
Owner’s Name _______________________________________________________
Installation Address ___________________________________________________
City, State, Zip________________________________________________________
Dealer’s Name Address ________________________________________________
City, State, Zip________________________________________________________
Type of Dealer _______________________________________________________
Model _________________________ Type of Gas _________________________
Serial No. ______________________
Date Purchased _________________
Comments: __________________________________________________________
____________________________________________________________________
PLEASE RETURN THIS CARD TO RINNAI WITHIN TWO WEEKS OF PURCHASE
AMERICA CORPORATION
103 International Drive
Peachtree City, Georgia 30269
Phone: 1-800-621-9419
RC-229-521
Printed in Japan
2002.2