Download Rheem Classic Series: Package Heat Pump Submittal Sheet

Transcript
SUBMITTAL COVER SHEET
PROJECT NAME ______________________________________________________________________________
LOCATION __________________________________________________________________________________
ARCHITECT__________________________________________________________________________________
ENGINEER __________________________________________________________________________________
CONTRACTOR ______________________________________________________________________________
SUBMITTED BY
______________________________ DATE ________________________________________
UNIT SUMMARY
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES:
PRINTED IN U.S.A.
NOTES:
10-06 DC
FORM NO. X11-1123 REV. 2
Supersedes Form No. X11-1123 Rev. 1
FORM NO. X33-1234 REV. 1
Supersedes Form No. X33-1234
SUBMITTAL SHEET FOR PACKAGE HEAT PUMPS
FEATURING EARTH-FRIENDLY R-410A REFRIGERANT:
RQNL- HIGH EFFICIENCY 13 SEER SERIES
RQPL- HIGH EFFICIENCY 14 SEER SERIES
Nominal Sizes 2 Thru 4 Tons [7.03 thru 14.07 kW]
JOB NAME
DATE
CONTRACTOR
UNIT DESIGNATION
ENGINEER
MODEL NO.
SUBMITTED FOR
APPROVAL
SUBMITTED BY
RECORD LOCATION
ORDER NO.
TOP VIEW
UNIT DATA
COOLING PERFORMANCE
4719/32"
[1209 mm]
TOTAL CAPACITY* ........................ _______ MBH
SENSIBLE CAPACITY* .................. _______ MBH
OUTDOOR DESIGN TEMP. _______ °F [°C] DB/WB
TOTAL SUPPLY AIR ................ _______ CFM [L/s]
TEMP. OF AIR ENTERING
EVAPORATOR COIL...... _______ °F [°C] DB/WB
POWER INPUT REQUIREMENT ...... _______ KW
SEER RATING........................................ _______
5013/16"
[1290 mm]
(*uses blower motor heat)
BOTTOM VIEW
HEATING PERFORMANCE
HEAT PUMP HEATING PERFORMANCE
CAPACITY @ 47°F .......................... ________MBH
CAPACITY @ 17°F .......................... ________MBH
COEFFICIENT OF PERFORMANCE
@ 47°F............................................ ________C.O.P.
@ 17°F............................................ ________C.O.P.
ELECTRIC HEAT CAPACITY ............ _______ KW
H.S.P.F. ...................................................... _______
451/16"
[1145 mm]
INSIDE
OUTDOOR FAN
GRILLE &
COMPRESSOR ACCESS
11/2"
[38 mm]
TYP.
BOTTOM
RETURN
DUCT
OPENING
SUPPLY AIR BLOWER PERFORMANCE
TOTAL SUPPLY AIR ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT ...... _______ KW
313/16"
[97 mm]
Sloped Curb
POWER SUPPLY...................... ____________ Hz
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES HACR BREAKER ........ _______ AMPS
TOTAL UNIT WEIGHT
TOTAL OPERATING WEIGHT .... _______ LBS [kg]
(including field-installed accessories)
CLEARANCES
2" [50.8 mm]
SIDE “B” (WITHOUT ECONOMIZER)
12" [304.8 mm]
SIDE “C” (WITHOUT ECONOMIZER)
48" [1,219.2 mm]
SIDE “D” (WITHOUT ECONOMIZER)
24" [610 mm]
ABOVE UNIT (WITHOUT ECONOMIZER) 60" [1,524 mm]
497/16"
[1256 mm]
INSIDE
141/4"
[362 mm]
TYP. 9
19 /16"
[497 mm]
ELECTRICAL DATA
SIDE “A” (WITHOUT ECONOMIZER)
13/16"
[30 mm]
TYP.
[ ] Designates Metric Conversions
45/16"
[95 mm]
BOTTOM
SUPPLY
DUCT
OPENING
153/8"
[391 mm]
33/16"
[97 mm]
FIELD INSTALLED ACCESSORIES
Roof Curb (14" [355.6 mm & 24" [609.6 mm]
Sloped Platform) ..............................................
Filter Accessory......................................................
Lift Kit (For Rigging) ..............................................
Time Delay Relay ..................................................
Start Assist ..........................................................
Low Ambient Control ..............................................
Low Pressure Control ............................................
Economizer (Enthalpy Controlled) Downflow Only ....
Manual Fresh Air Damper ......................................
L.P. (Propane) Kit ..................................................
Transition (Rectangular-Round) Downflow/Sideflow ..
Concentric Diffuser and Grille ..................................
High Pressure Control ............................................
Thermostat ..........................................................
SIDE VIEW
SIDE VIEW
OUTDOOR
COIL PROTECTIVE
GRILLE
FILTER ACCESS PANEL (FOR UNIT
MOUNTED FILTER ACCESSORY
THERMOSTAT
WIRE ENTRANCE
11/8"
[29 mm]
255/16"
[643 mm]
103/16"
[259 mm]
51/16"
[129 mm]
ELECTRICAL
POWER ENTRANCE
43/4"
[121 mm]
527/16"
[1332 mm]
BLOWER/
EVAPORATOR
ACCESS PANEL
FRONT VIEW
REAR VIEW
CONTROL
ACCESS PANEL
47/8"
[124 mm]
SIDE SUPPLY
DUCT OPENING
LIQUID
PRESSURE
SERVICE PORT
75/16"
[186 mm]
2211/16"
[576 mm]
471/2"
[1207 mm]
THREADED PVC
CONDENSATED DRAIN
CONNECTION (3/4 N.P.T.)
SUCTION PRESSURE
SERVICE PORT
133/4"
[349 mm]
21/2" [63.5 mm]
47/16"
[113 mm]
57/16" [138 mm]
81/2"
[216 mm]
TYP.
15"
[381 mm]
143/16"
[360 mm]
TYP.
191/8"
[486 mm]
SIDE RETURN
DUCT OPENING
SHOWN WITH DUCT COVERS REMOVED.
Model Number
Height “A”
B024, B025
3515/16
B030, B036, B042, B048
41
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A.
8-09 DC
FORM NO. X33-1234 REV. 1
Supersedes Form No. X33-1234