Download NEC N8406-023 Command Reference Guide
Transcript
Uplink Failure Detection configuration Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use these commands to configure four Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. When UFD is enabled and a Failure Detection Pair is configured, the switch automatically disables ports in the LtD if it detects a failure in the LtM. The failure conditions which are monitored in the LtM group include port link state moving to down, or port state moving to Blocking if Spanning Tree Protocol is enabled. The following table describes the Uplink Failure Detection (UFD) Configuration commands. Table 172 Uplink Failure Detection Configuration commands Command Description ufd enable Globally turns Uplink Failure Detection ON. Command mode: Global configuration Globally turns Uplink Failure Detection OFF. The default is OFF. Command mode: Global configuration Enter FDP configuration mode for the selected number. Command mode: Global configuration Displays the current Uplink Failure Detection configuration parameters. Command mode: All no ufd enable ufd fdp <fdp number> show ufd Failure Detection Pair configuration Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM) and one Link to Disable (LtD). When the switch detects a failure on the LtM, it automatically disables the ports in the LtD. The following table describes the Failure Detection Pair (FDP) configuration commands. Table 173 Failure Detection Pair Configuration commands Command Description enable Enables the FDP Parameters. Command mode: FDP configuration Disables the FDP Parameters. The default is disabled. Command mode: FDP configuration no enable Link to Monitor configuration The following table describes the Link to Monitor (LtM) commands. The LtM can consist of only one uplink port (ports 20-24), a single trunk containing only uplink ports, or a single LACP trunk containing only uplink ports. Table 174 Link to Monitor commands Command Description ltm port <port number> Adds a port to the LtM. Only uplink ports (20-24) are allowed in the LtM. Command mode: FDP configuration Removes a port from the LtM. Command mode: FDP configuration Adds a trunk group to the LtM. The LtM trunk group can contain only uplink ports (20-24). Command mode: FDP configuration Removes a trunk group from the LtM. Command mode: FDP configuration Adds a LACP trunk group to the LtM. Defines a adminkey configured to a LACP trunk group. The LtM LACP trunk group can contain only uplink ports (20-24). Command mode: FDP configuration Removes a LACP trunk group from the LtM. Command mode: FDP configuration no ltm port <port number> ltm portchannel <1-12> no ltm portchannel <1-12> ltm adminkey <1-65535> no ltm adminkey <1-65535> N8406-023 1Gb Intelligent L3 Switch Command Reference Guide (ISCLI) 143