Download NEC Express5800/320Ma Technical Reference Guide
Transcript
ftSMC Component Actions Table 3-2. ftSMC System Inventory Component Actions (Continued) Action Description Set Rdr Lun Load Balancing Sets read load balancing for RDR virtual disks to on or off. Set Resync Priority Sets the resynchronization priority for individual RDR disks. Start Slot Identification Causes the LEDs on the disk in the slot to flash so that you can physically locate a disk that is experiencing a problem. Stop Slot Identification Stops the LEDs on the disk from flashing. See Start Slot Identification. Stop Verify Stops the RDR disk verification operation. Synchronize SEL date and time with System Assigns the current system date and time to the SELTime property. Update BMC Firmware Updates the BMC firmware. See the Express5800/320Ma: Software Installation and Configuration Guide for details. Update Firmware Updates a device’s firmware (for example, the BIOS in the CPU element, or the firmware for storage enclosures or VTMs). Prompts you to enter the path of the file containing the updated firmware and copies the file to the appropriate location. This action may be unavailable if the device is online. See the Express5800/320Ma: Software Installation and Configuration Guide for details. Update ID Prom Updates the IDPROM information. See IDPROM in Table 3-1 for IDPROM information. When you finish, click Apply. A dialog box displays the status of the operation. Update Network Settings Updates the VTM network settings. Verify RDR Virtual Disk Verifies the integrity of RDR disk mirrors. ftSMC Component Properties and Actions 3-27