Download National Instruments PXI-8460 User's Manual
Transcript
Appendix B Cabling Requirements for PXI-8460 Low-Speed CAN Cable Specifications Cables should meet the physical medium requirements specified in ISO 11519-2, shown in Table B-2. Belden cable (3084A) meets all of those requirements, and should be suitable for most applications. Table B-2. ISO 11519-2 Specifications for Characteristics of a CAN_H and CAN_L Pair of Wires Characteristic Value Length-related resistance 90 mΩ/m nominal Length-related capacitance: CAN_L and ground, CAN_H and ground, CAN_L and CAN_H 30 pF/m nominal Number of Devices The maximum number of devices depends on the electrical characteristics of the devices on the network. If all of the devices meet the requirements of ISO 11519-2, at least 20 devices may be connected to the bus. Higher numbers of devices may be connected if the electrical characteristics of the devices do not degrade signal quality below ISO 11519-2 signal level specifications. PXI-846x and NI-CAN for Windows NT B-4 ni.com