Download Lightolier LP-4 User's Manual

Transcript
Lighting Systems
1BHFPG
LP-4
-JOFBS1FSG-ZUFÜDN
4FNJ1FSGPSBUFE-JHIU51FS'PPU/PNJOBM
4FDUJPO
2.5”
(6.35cm)
9” (22.86cm)
Half Scale
98” (248.92cm)
2” (5.08cm)
2” (5.08cm)
2” (5.08cm)
Bottom View
Module Ordering Information
Style
Series
Type
LP
1
B
Lamps
Length
Options
Ballast
3T8
3T8 = 3-F32T8
4 = 4-Foot
8 = 8-Foot
12 = 12-Foot
Complete ordering instructions below.
U = Universal Voltage
E = Emergency Pack
D1 = Dimming 120v
D2 = Dimming 277v
Blank = No Options
DS = A-B Switch
X4 = 4 Wire for Dimming &
Switched Emergency
Features
Ordering Information
1. Housing: 18 gauge perforated steel with 41% open hole pattern. Holes are
1/16” (0.16cm) diameter on 3/32” (0.24cm) centers. Die-formed steel end cap
with concealed access holes for through wiring. No exposed fasteners or
hardware.
2. Lamping: Three T8 32 watt fluorescent lamps per 4-foot section. Center lamp
is mounted diagonally. Lamps provided by others.
3. Reflector: Precision die-formed specular aluminum.
4. Diffuser: Opal acrylic diffuser.
Individual Fixtures:
1. Order number of MODULES required.
2. Order one POWER FEED END SET per MODULE.
Electrical
Ballast is universal voltage, <10% THD, .88 ballast factor, instant start. 3 conductor, 18 gauge wire. Color-coded quick connectors allow ease of connection
for joiner modules. For special circuiting consult factory. Cord is 18/3 SJT. Factory
installed ballast disconnect allows the ballast to be disconnected from and
reconnected to incoming power under load without turning the entire circuit off.
Dimming: 120/277 VAC, 4 wire feed required.
Emergency Battery Pack: 32 watt: 450 lumens @ 90 minutes.
Continuous Rows:
1. Determine run length.
2. Order the appropriate number of MODULES for the complete run.
3. Order one POWER FEED END SET per run.
4. Order one CABLE ASSEMBLY per MODULE minus one per run.
5. For runs that exceed amperage limits, order the appropriate number of SINGLE
CABLE & CORD FEEDS.
Finish
Powder coated baked white enamel. Custom colors available, consult factory.
Labels
UL, cUL and I.B.E.W.
Mountings
Cable Suspension (not shown) - 4-1/2” (11.43cm) diameter flat canopy finished
white enamel, 1/16” (0.16cm) diameter stainless steel aircraft cable adjustable up
to 36” (91.44cm) without cutting. Overlap connector to provided 46” (116.84cm) of
perforated and 2” (5.08cm) solid sections contiguously without the presence of
hairline connections (see Bottom View drawing above).
Job Information
Type:
Job Name:
Cat. No.:
Options
Dual Switching: Order the DS option for separate row switching. DS option
automatically ships with the X4 option included.
4 Wire: Order X4 modules for remainder of the run when using dimming and/or
switched emergency battery pack modules. Also, order the 4 Wire Cord Power Feed
End Sets (LP1EC36X4) when using 4 Wire Modules.
Emergency Circuiting: Special circuiting - consult factory.
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."t
t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #
Lighting Systems
1BHFPG
LP-4
-JOFBS1FSG-ZUFÜDN
4FNJ1FSGPSBUFE-JHIU51FS'PPU/PNJOBM
4FDUJPO
Performance
ZONE
DEG.
REPORT NO: LRL 200-10G
CAT NO: LP1B3T84U
LAMPS: 3 F32T8
LUMENS: 2900
EFFICIENCY: 75.7%
180
175
165
155
145
135
125
115
105
95
90
85
75
65
55
45
35
25
15
5
0
0
1365
1353
1305
1217
1056
852
675
450
241
52
17
16
26
35
76
97
130
155
171
180
180
CANDLEPOWER
22
45
CANDELAS
1365 1365
1364 1375
1372 1435
1351 1481
1268 1453
1115 1354
973 1295
795 1045
547
680
165
199
37
59
21
29
33
39
46
56
81
98
101
108
131
136
155
157
171
173
179
182
180
180
67
1365
1396
1522
1625
1655
1618
1550
1166
721
226
89
45
51
69
105
123
144
161
174
180
180
1365
1400
1526
1656
1703
1672
1512
1195
727
237
94
50
54
72
110
126
149
162
174
181
180
Fixture Lengths & Mounting Locations
4’
8’
4’ 2” (127.00cm)
8’ 2” (248.92cm)
144” (366.62cm)
12’
12’ 2” (370.84cm)
96” (243.84cm)
16’
80
70
50
WALL REFLECTANCE
70 50 30 70 50 30 50 30
0 74 74 74 64 64 64 45 45
1 67 64 61 58 55 53 39 38
2 61 56 51 53 48 45 35 32
3 55 49 44 48 43 38 31 28
4 51 43 38 44 38 33 27 24
5 46 38 32 40 33 29 24 21
6 42 34 28 37 30 25 21 18
7 39 30 25 34 27 22 19 16
8 36 27 22 31 24 19 17 14
9 33 25 19 29 22 17 16 13
10 31 22 17 27 20 15 14 11
20% FLOOR CAVITY REFLECTANCE
DISTRIBUTION
Lumens
Zone
0-90
530
90-180 6055
0-180
6585
% Lamp
6.1
69.6
75.7
10
45
37
31
26
22
18
16
14
12
11
9
% Luminaire
8.0
92.0
100.0
4-Foot 8-Foot 12-Foot
End Set
Module Module Module
4-Foot Run
1
1
8-Foot Run
1
1
12-Foot Run
1
1
16-Foot Run
2
1
20'-Foot Run
1
1
1
24'-Foot Run
2
1
96” (243.84cm)
48” (121.92cm)
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY
REFLECTANCE
90
ROOM CAVITY RATIO
CANDLEPOWER CURVE
Cable/
Joiner
1
1
1
96” (243.84cm)
16’ 2” (492.76cm)
144” (366.62cm)
96” (243.84cm)
20’
20’ 2” (614.68cm)
144” (366.62cm)
24’
144” (366.62cm)
24’ 2” (736.60cm)
Mounting Accessories
Cable/Joiner Assembly
Standard Cable Length is 36” (91.44cm)
Single Cable: LP1C36
Single Cable & Cord: LP1CC36
Single Cable & 4 Wire Cord: LP1CC36X4
Power Feed End Set
Standard Cable Length is 36” (91.44cm)
Straight Cord: LP1EC36 4 Wire Cord*: LP1EC36X4
Ceiling Grid Kit CGK
Includes both Standard 1” (2.54cm)
Tee Bar Clip & Slot Tee Clip
* use for dimming and/or emergency battery packs
Job Information
Type:
"JSQPSU3PBE'BMM3JWFS."t
t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #