Download Lightolier LP-4 User's Manual
Transcript
Lighting Systems 1BHFPG LP-4 -JOFBS1FSG-ZUFÜDN 4FNJ1FSGPSBUFE-JHIU51FS'PPU/PNJOBM 4FDUJPO 2.5” (6.35cm) 9” (22.86cm) Half Scale 98” (248.92cm) 2” (5.08cm) 2” (5.08cm) 2” (5.08cm) Bottom View Module Ordering Information Style Series Type LP 1 B Lamps Length Options Ballast 3T8 3T8 = 3-F32T8 4 = 4-Foot 8 = 8-Foot 12 = 12-Foot Complete ordering instructions below. U = Universal Voltage E = Emergency Pack D1 = Dimming 120v D2 = Dimming 277v Blank = No Options DS = A-B Switch X4 = 4 Wire for Dimming & Switched Emergency Features Ordering Information 1. Housing: 18 gauge perforated steel with 41% open hole pattern. Holes are 1/16” (0.16cm) diameter on 3/32” (0.24cm) centers. Die-formed steel end cap with concealed access holes for through wiring. No exposed fasteners or hardware. 2. Lamping: Three T8 32 watt fluorescent lamps per 4-foot section. Center lamp is mounted diagonally. Lamps provided by others. 3. Reflector: Precision die-formed specular aluminum. 4. Diffuser: Opal acrylic diffuser. Individual Fixtures: 1. Order number of MODULES required. 2. Order one POWER FEED END SET per MODULE. Electrical Ballast is universal voltage, <10% THD, .88 ballast factor, instant start. 3 conductor, 18 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting consult factory. Cord is 18/3 SJT. Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off. Dimming: 120/277 VAC, 4 wire feed required. Emergency Battery Pack: 32 watt: 450 lumens @ 90 minutes. Continuous Rows: 1. Determine run length. 2. Order the appropriate number of MODULES for the complete run. 3. Order one POWER FEED END SET per run. 4. Order one CABLE ASSEMBLY per MODULE minus one per run. 5. For runs that exceed amperage limits, order the appropriate number of SINGLE CABLE & CORD FEEDS. Finish Powder coated baked white enamel. Custom colors available, consult factory. Labels UL, cUL and I.B.E.W. Mountings Cable Suspension (not shown) - 4-1/2” (11.43cm) diameter flat canopy finished white enamel, 1/16” (0.16cm) diameter stainless steel aircraft cable adjustable up to 36” (91.44cm) without cutting. Overlap connector to provided 46” (116.84cm) of perforated and 2” (5.08cm) solid sections contiguously without the presence of hairline connections (see Bottom View drawing above). Job Information Type: Job Name: Cat. No.: Options Dual Switching: Order the DS option for separate row switching. DS option automatically ships with the X4 option included. 4 Wire: Order X4 modules for remainder of the run when using dimming and/or switched emergency battery pack modules. Also, order the 4 Wire Cord Power Feed End Sets (LP1EC36X4) when using 4 Wire Modules. Emergency Circuiting: Special circuiting - consult factory. Lamp(s): Notes: "JSQPSU3PBE'BMM3JWFS."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt # Lighting Systems 1BHFPG LP-4 -JOFBS1FSG-ZUFÜDN 4FNJ1FSGPSBUFE-JHIU51FS'PPU/PNJOBM 4FDUJPO Performance ZONE DEG. REPORT NO: LRL 200-10G CAT NO: LP1B3T84U LAMPS: 3 F32T8 LUMENS: 2900 EFFICIENCY: 75.7% 180 175 165 155 145 135 125 115 105 95 90 85 75 65 55 45 35 25 15 5 0 0 1365 1353 1305 1217 1056 852 675 450 241 52 17 16 26 35 76 97 130 155 171 180 180 CANDLEPOWER 22 45 CANDELAS 1365 1365 1364 1375 1372 1435 1351 1481 1268 1453 1115 1354 973 1295 795 1045 547 680 165 199 37 59 21 29 33 39 46 56 81 98 101 108 131 136 155 157 171 173 179 182 180 180 67 1365 1396 1522 1625 1655 1618 1550 1166 721 226 89 45 51 69 105 123 144 161 174 180 180 1365 1400 1526 1656 1703 1672 1512 1195 727 237 94 50 54 72 110 126 149 162 174 181 180 Fixture Lengths & Mounting Locations 4’ 8’ 4’ 2” (127.00cm) 8’ 2” (248.92cm) 144” (366.62cm) 12’ 12’ 2” (370.84cm) 96” (243.84cm) 16’ 80 70 50 WALL REFLECTANCE 70 50 30 70 50 30 50 30 0 74 74 74 64 64 64 45 45 1 67 64 61 58 55 53 39 38 2 61 56 51 53 48 45 35 32 3 55 49 44 48 43 38 31 28 4 51 43 38 44 38 33 27 24 5 46 38 32 40 33 29 24 21 6 42 34 28 37 30 25 21 18 7 39 30 25 34 27 22 19 16 8 36 27 22 31 24 19 17 14 9 33 25 19 29 22 17 16 13 10 31 22 17 27 20 15 14 11 20% FLOOR CAVITY REFLECTANCE DISTRIBUTION Lumens Zone 0-90 530 90-180 6055 0-180 6585 % Lamp 6.1 69.6 75.7 10 45 37 31 26 22 18 16 14 12 11 9 % Luminaire 8.0 92.0 100.0 4-Foot 8-Foot 12-Foot End Set Module Module Module 4-Foot Run 1 1 8-Foot Run 1 1 12-Foot Run 1 1 16-Foot Run 2 1 20'-Foot Run 1 1 1 24'-Foot Run 2 1 96” (243.84cm) 48” (121.92cm) COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE 90 ROOM CAVITY RATIO CANDLEPOWER CURVE Cable/ Joiner 1 1 1 96” (243.84cm) 16’ 2” (492.76cm) 144” (366.62cm) 96” (243.84cm) 20’ 20’ 2” (614.68cm) 144” (366.62cm) 24’ 144” (366.62cm) 24’ 2” (736.60cm) Mounting Accessories Cable/Joiner Assembly Standard Cable Length is 36” (91.44cm) Single Cable: LP1C36 Single Cable & Cord: LP1CC36 Single Cable & 4 Wire Cord: LP1CC36X4 Power Feed End Set Standard Cable Length is 36” (91.44cm) Straight Cord: LP1EC36 4 Wire Cord*: LP1EC36X4 Ceiling Grid Kit CGK Includes both Standard 1” (2.54cm) Tee Bar Clip & Slot Tee Clip * use for dimming and/or emergency battery packs Job Information Type: "JSQPSU3PBE'BMM3JWFS."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #