Download Kenmore 808353 User's Manual
Transcript
FIGURE48 Connecting a voltmeter in series with the Bi-Metal as shown in Figure 48 will permit a quick check of the circuit If the circuit is good, tine voltage will be indicated when the timer is advanced to the Detergent Dispenser Inclement with th'e dishwasher connected to a power source_ The Bi-Metal will not heat with the voltmeter connected, due to the high resistance of tile meten Failure of the Bi-Metal to operate can usually be traced to a poor connection, faulty contact or an open iead The Bi-Metal itself is a highly reliable component, If the circuitry is found to be satisfactory, the latching surfaces of the cam and trigger should be checked for roughness, CAUTION: Do not apply line voltage across the Bi.,Metal, as this would destroy it, The Bi-Metal leaf is an integral part of the electric circuit, tf it becomes necessary to touch the leaf for any _eason, turn off the power to the dishwasher Although the Bi-Metal is a tow voltage component, it is possible to have a 120 volt potential from _he Bi-Metal to ground when the Bi-Metai circuit is open 14 15 3 FIGURE49 46 Ref, No, Description 1, 2 3 4 5 6o 7 8 9 10 11 12 13 14. 15, 16 Bi-Metal Trigger Screw Screw Cam Roll Pin-Cam Spring-Cam Spring-Cam-Compression Nut Bracket-Actuator Washer Bushing "0" Ring Shaft Cup- Detergent Cover-Cup "0" Ring