Download Hitachi L300IP User's Manual

Transcript
Analog Input Configuration
The following tables show the parameter settings required for various
analog input signal types.
A006
A005
[AT]
External
Frequency
Command
Input
Trim
Frequency
Command
Input
Reverse
available
(bipolar
input)
00
00
OFF
[O] — [L]
✘
✘
ON
[OI] — [L]
✘
✘
01
OFF
[O] — [L]
✘
✘
ON
[O2] — [L]
✘
✔
OFF
[O] — [L]
[O2] — [L]
✘
ON
[OI] — [L]
[O2] — [L]
✘
OFF
[O] — [L]
[O2] — [L]
✘
ON
[O2] — [L]
✘
✔
OFF
[O] — [L]
[O2] — [L]
✔
ON
[OI] — [L]
[O2] — [L]
✔
OFF
[O] — [L]
[O2] — [L]
✔
ON
[O2] — [L]
✘
✔
01
00
01
02
00
01
The table below applies when the [AT] input function is not assigned to
any intelligent input terminal. The A005 setting, normally used in conjunction with an [AT] input, is ignored.
A006
A005
00
—
01
—
02
—
[AT]
External
Frequency
Command
Input
[O2] — [L]
(not
assigned
to any Summation of
input [O] — [L] and
[OI] — [L]
terminal)
Summation of
[O] — [L] and
[OI] — [L]
29
Trim
Frequency
Command
Input
Reverse
available
(bipolar
input)
✘
✔
[O2] — [L]
✘
[O2] — [L]
✔