Download Goodman Mfg RT6332013r1 User's Manual
Transcript
TECHNICAL MANU AL MANUAL GPH 13 M Series Multi Position Package Heat Pump Units with R410A • Refer to Service Manual RS6300008 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2010 Goodman Manufacturing Company, L.P. RT6332013r1 November 2010 PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. G P BRAND: G: Goodman® Brand A: Amana® Brand H 13 36 A A REFRIGERANT: 4: R-410A PRODUCT SERIES: 13: Up to 13 SEER MAJOR REVISION: A: Initial Release CONFIGURATION: M: Mult-position VOLTAGE: 1: 208-230v/1ph/60Hz 3. 208-230v/3ph/60Hz 4. 460V/3ph/60Hz HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. 2 1 PRODUCT FAMILY: H: Heat Pump NOMINAL CAPACITY: 24: 24,000 BTUH 30: 30,000 BTUH 36: 36,000 BTUH 42: 42,000 BTUH 48: 48,000 BTUH 60: 60,000 BTUH WARNING 4 MINOR REVISION: A: Initial Release PRODUCT TYPE: Package Unit WARNING M Installation and repair of this unit should be performed ONLY by individuals meeting (at a minimum) the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPH1324M41AB GPH1330M41AB GPH1336M41AB GPH1342M41AB GPH1348M41AB GPH1360M41AB WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN GPH13 (M Series) Package Units are designed for outdoor installations only in either residential or light commercial applications and are available in 2, 2.5, 3, 3.5, 4 & 5 ton sizes. They are designed for 208/230 volt single phase applications. The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical application, a matching Roof Curb is recommended and a horizontal duct cover kit is required. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated without return air filters. A 3/4" pipe is provided for removal of condensate water from the indoor coil. A trap must be provided to have proper condensate drainage. (Do not reduce the drain line size). Refrigerant flow control is achieved by use of restrictor orifices. All heat pump models also have a suction line accumulator installed between the reversing valve and the compressor. The object of the accumulator is to: 1. Provide a liquid refrigerant storage vessel during prolonged system off cycles. 2. Store excess liquid refrigerant not needed by the system while running. 3. Return oil and saturated vapor to the compressor at a controlled rate. 4. Retain stored excess refrigerant during a sudden system pressure fluctuation such as seen in defrost cycles. Refrigerant flow control is achieved by use of restrictor orifices. These models use the FasTest Access Fitting System, with a saddle that is either soldered to the suction and liquid lines or is fastened with a locking nut to the access fitting box (core) and then screwed into the saddle. Do not remove the core from the saddle until the refrigerant charge has been removed. Failure to do so could result in property damage or personal injury. The single phase units use permanent split capacitor (PSC) design compressors. Starting components are not required for these units. A low microfarad run capacitor assists the compressor to start and remains in the circuit during operation. The outdoor fan motors are single phase capacitor type motors. Some models use PSC type indoor blower motors while others use EEM type blower motors. EEM motors are energized by a 24V signal from the thermostat and are constant torque motors with very low power consumption. The EEM features an integral control module. 4 Air for condensing (cooling cycle) or evaporation (heating cycle) is drawn through the outdoor coil by a propeller fan, and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction (ductwork) shall be applied. Conditioned air is drawn through the filter(s), field installed, across the coil and back into the conditioned space by the indoor blower. Package Heat Pump indoor sections are designed to accept optional components such as auxiliary electric heaters and circuit breakers. Provisions for these components have been made at time of manufacture. GPH13 series package units use the Compliant Scroll compressor; there are a number of design characteristics which are different from the traditional reciprocating compressor. - Due to their design Scroll compressors are inherently more tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued flood back or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure. - These Scroll compressors use "POE" or polyolester oil which is NOT compatible with mineral oil based lubricants like 3GS. "POE" oil must be used if additional oil is required. - Compliant scroll compressors perform “quiet” shutdowns that allow the compressor to restart immediately without the need for a time delay. This compressor will restart even if the system has not equalized. - Operating pressures and amp draws may differ from standard reciprocating compressors. This information may be found in the “Cooling Performance Data” section. Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. PRODUCT DESIGN In installations where the unit is installed above ground level and not serviceable from the ground (Example: roof top installations) the installer must provide service platform for service person with rails or guards in accordance with local codes or ordinances, or, in their absence, with the latest edition of the Uniform Mechanical Code Section 305. NOTE: Unit can also use roof curb (and platform for leveling, where necessary) to utilize bottom discharge. WARNING TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING IF A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING. Outside Slab Installation -Multi-positional (M) NOTE: Roof overhang should be no more than 36" and provisions made to deflect the warm discharge air out from the overhang. Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. IMPORTANT: If using bottom discharge with roof curb, ductwork should be attached to the curb prior to installing the unit. NOTE: Single phase models require installation of horizontal duct kit #20464501PDGK (medium chassis) and #20464502PDGK (large chassis) when using bottom discharge. Refer to Roof curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Roof Curb Rooftop Installation - -Multi-positional (M) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. 5 PRODUCT DESIGN GPH13[24-60]M41* HKR ELECTRICAL DATA Circuit #1 Circuit #2 Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V Actual kW & BTU at 240V GPH1324M41* HKR05A,CA HKR08A,CA HKR10A,CA 24 / 27 33 / 28 45 / 51 30 / 30 40 / 40 60 / 60 ---------- ---------- 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 GPH1330M41* HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA 24 / 27 34 / 39 45 / 52 45 / 52 30 / 30 40 / 40 60 / 60 60 / 60 ---22 / 25 ---30 / 30 4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 GPH1336M41* HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA 24 / 27 34 / 39 45 / 52 45 / 52 30 / 30 40 / 40 60 / 60 60 / 60 ---------22 / 25 ---------30 / 30 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 14.25 / 48,600 GPH1342M41* HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA 24 / 27 34 / 39 45 / 52 45 / 52 30 / 30 40 / 40 60 / 60 60 / 60 ---22 / 25 ---30 / 30 4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 25 / 28 30 / 30 ---- ---- 4.75 / 16,200 34 / 40 46 / 53 46 / 52 46 / 52 40 / 40 60 / 60 60 / 60 60 / 60 ------22 / 25 43 / 49 ------30 / 30 60 / 60 7.00 / 23,800 9.50 / 32,400 14.25 / 48,600 19.50 / 66,500 26 / 30 36 / 40 48 / 54 48 / 54 48 / 54 30 / 30 40 / 40 60 / 60 60 / 60 60 / 60 ---------22 / 25 43 / 49 ---------30 / 30 60 / 60 4.75 / 16,200 7.00 / 23,800 9.50 / 32,400 14.25 / 48,600 19.50 / 66,500 GPH1348M41* HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA HKR20A,CA GPH1360M41* HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA HKR20A,CA IMPORTANT NOTE: A separate power supply is required for the HKR heater kit. Heating kW Correction Factor Supply Votage 240 230 220 210 208 Correction Factor 1.0 0.93 0.85 0.78 0.76 Multiply rated kW by correction factor to get actual kW WARNING 6 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE UNIT SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle. PRODUCT DIMENSIONS GPH13[24-60]M41* 47 51 POWER WIRE ENTRANCE 4 1/8 2 1/8 16 1 3/8 A? 5½ 16 6½ B 8 2 34 RETURN B? SUCTION/LIQUID PRESSURE PORT SUPPLY 3 CONDENSATE DRAIN CONNECTION 3/4” NPT FEMALE 18 7/8 CONTROL WIRE ENTRANCE BLOWER ACCESS PANEL MEDIUM CHASSIS GPH1324M41* GPH1330M41* GPH1336M41* GPH1342M41* LARGE CHASSIS GPH1348M41* GPH1360M41* 7 PACKAGE HEAT PUMP SPECIFICATIONS GPH13[24-36]M41AB GPH1324M41* GPH1330M41* GPH1336M41* COOLING COOLING CAPACITY, BTUH 24,000 29,000 34600 CAPACITY SEER / EER 13/11 13/10.8 13/10.9 HEATING BTU/h (47°) 23000 28800 34200 RATING BTU/h (17°) 12600 17000 19000 HSPF 7.7 7.7 7.7 208/230-60-1 208/230-60-1 208/230-60-1 15.8 19.0 21.3 19.0 23.0 25.4 30 35 40 SCROLL SCROLL SCROLL RATED LOAD AMPS 12.8 16.0 16.7 LOCKED ROTOR AMPS 58.3 77 79 CONDENSER HORSEPOWER 1/4 1/4 1/4 FAN MOTOR RPM 830 830 830 FULL LOAD AMPS 1.5 1.5 1.5 3 3 3 22/3 22/3 22/4 17.02 17.02 16.83 UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS SPECIFICATION MIN CIRCUIT AMPACITY MAX OVERCURRENT PROTECTION COMPRESSOR (1 ) TYPE LOCKED ROTOR AMPS CONDENSER FAN BLADE DIAMETER (INCHES) NUMBER OF BLADES CONDENSER FACE AREA (SQ. FT.) COIL NUMBER OF ROWS 1 1 1 FINS PER INCH 24 24 22 1/4 - 3 1/3 - 3 1/3 - 3 EVAPORATOR HORSEPOWER - NUMBER OF SPEEDS BLOWER FULL LOAD AMPS 1.5 1.5 3.06 MOTOR LOCKED ROTOR AMPS 2.13 3.2 4.1 MOTOR SPEED TAP - COOLING X-13 High High High RPM 952 869 910 10 x 9 10 x 9 10 x 9 1150 EVAPORATOR DIAMETER X WIDTH (INCHES) BLOWER RATED SCFM COOLING 825 1050 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 EVAPORATOR FACE AREA (SQ. FT.) 4.52 4.52 4.52 COIL NUMBER OF ROWS 4 4 4 FINS PER INCH 16 16 14 25 x 25 x 1 25 x 25 x 1 25 x 25 x 1 3/4" 3/4" 3/4" 0.057/0.045 0.070/0.055 0.071/0.057 REFRIGERANT CHARGE R410A (OZS.) 110 115 135 POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES) 1/2 1/2 1/2 22 / 50 22 / 50 22 / 50 GENERAL FILTER SIZE * INFORMATION DRAIN SIZE (INCHES) EXPANSION DEVICE (ID/OD) LO PRESSURE SWITCH OPENS / CLOSES PSIG HI PRESSURE SWITCH - OPENS PSIG 660 / 420 660 / 420 660 / 420 SHIPPING WEIGHT (LBS.) OPENS / CLOSES PSIG 405 410 435 OPERATING WEIGHT (LBS.) 395 400 425 (1) * Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 8 PACKAGE HEAT PUMP SPECIFICATIONS GPH13[42-60]M41AB GPH1342M41* GPH1348M41* GPH1360M41* COOLING COOLING CAPACITY, BTUH 40000 46500 56000 CAPACITY SEER / EER 13/11 13/11 13/10.9 HEATING BTU/h (47°) 40000 45500 55500 RATING BTU/h (17°) 21000 26000 31200 HSPF 7.7 8.0 8.0 208/230-60-1 208/230-60-1 208/230-60-1 AMPS 22.4 29.0 35.4 MIN CIRCUIT AMPACITY 26.8 34.5 42.0 UNIT VOLTAGE (NAMEPLATE) ELECTRICAL SPECIFICATION (1) 40 50 60 SCROLL SCROLL SCROLL RATED LOAD AMPS 17.9 21.8 26.4 LOCKED ROTOR AMPS 112 117 134 CONDENSER HORSEPOWER 1/4 1/4 1/4 FAN MOTOR RPM MAX OVERCURRENT PROTECTION COMPRESSOR TYPE 1075 1075 1075 FULL LOAD AMPS 1.4 1.4 1.4 LOCKED ROTOR AMPS 2.9 2.9 2.9 CONDENSER FAN BLADE DIAMETER (INCHES) NUMBER OF BLADES 22/3 22/3 22/3 CONDENSER FACE AREA (SQ. FT.) 16.83 19.24 21.04 COIL NUMBER OF ROWS 2 2 2 FINS PER INCH 16 16 16 1/3 - 3 3/4 - 5 1- 5 7.6 EVAPORATOR HORSEPOWER - NUMBER OF SPEEDS BLOWER FULL LOAD AMPS 3.06 5.8 MOTOR LOCKED ROTOR AMPS 4.1 --- --- High T2/T3 T2/T3 MOTOR SPEED TAP - COOLING X-13 910 1050 1050 EVAPORATOR RPM DIAMETER X WIDTH (INCHES) 10 x 9 10 x 9 10 x 9 BLOWER RATED SCFM COOLING 1800 1300 1720 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 EVAPORATOR FACE AREA (SQ. FT.) 4.52 6.17 6.17 COIL NUMBER OF ROWS 4 4 4 FINS PER INCH 14 14 14 25 x 25 x 1 (2) 20 x 20 x 1 (2) 20 x 20 x 1 GENERAL FILTER SIZE * INFORMATION DRAIN SIZE (INCHES) 3/4" 3/4" 3/4" 0.072/0.063 0.080/0.065 0.084/0.076 REFRIGERANT CHARGE R410A (OZS.) 180 190 220 POWER SUPPLY CONDUIT KNOCKOUT SIZE (INCHES) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (INCHES) 1/2 1/2 1/2 22 / 50 22 / 50 22 / 50 660 / 420 660 / 420 660 / 420 SHIPPING WEIGHT (LBS.) 440 520 533 OPERATING WEIGHT (LBS.) 430 510 523 EXPANSION DEVICE (ID/OD) LO PRESSURE SWITCH OPENS / CLOSES PSIG HI PRESSURE SWITCH - OPENS PSIG OPENS / CLOSES PSIG (1) * Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 9 ACCESSORIES GPH13[24-60]M41* ACCESSORIES - GPC/GPH****M MODELS Part Number Description OT18-60A Outdoor Thermostat Kit w/Lockout Stat OT/EHR18-60 Emergency Heat Relay Kit HKR Electric Heat Kit PGC101/102/103 Roof Curb PEHH101/102 Horizontal Economizer For Heat Pump, Small and Medium Chassis PEHH103 Horizontal Economizer For Heat Pump, Large Chassis PEHC101/102 Horizontal Economizer For A/C, Small and Medium Chassis PEHC103 Horizontal Economizer For A/C, Large Chassis PGMDD101/102 Manual 25% Fresh Air Damper Downflow Application, Small and Medium Chassis PGMDD103 Manual 25% Fresh Air Damper Downflow Application, Large Chassis PGMDH102 Manual 25% Fresh Air Damper Horizontal Application, Medium Chassis PGMDH103 Manual 25% Fresh Air Damper Horizontal Application, Large Chassis PGMDMD101/102 Motorized 25% Fresh Air Damper Downflow Application,Small and Medium Chassis PGMDMD103 Motorized 25% Fresh Air Downflow Application, Large Chassis PGMDMH102 Motorized 25% Fresh Air Damper Horizontal Application, Medium Chassis PGMDMH103 Motorized 25% Fresh Air Damper Horizontal Application, Large Chassis GPC13MED102 Downflow Economizer For A/C, Medium Chassis GPC13MED103 Downflow Economizer For A/C, Large Chassis GPH13MED102 Downflow Economizer For Heat Pump, Medium Chassis GPH13MED103 Downflow Economizer For Heat Pump, Large Chassis GPH13MFR102 Internal Filter Rack, Medium Chassis GPH13MFR103 Internal Filter Rack, Large Chassis GPGHFR101-103 External Horizontal Filter Rack for Goodman/Amana Gas/Electric and Multi-position Package Units All Chassis SQRPG101/102 Square to Round Adapter w/ 16" Round Downflow Application, Medium Chassis SQRPG103 Square to Round Adapter w/ 18" Round Downflow Application, Large Chassis SQRPGH101/102 Square to Round Adapter w/ 16" Round Horizontal Application, Medium Chassis SQRPGH103 Square to Round Adapter w/ 18" Round Horizontal Application, Large Chassis CDK36 Flush Mount Concentric Duct Kit CDK36515 Flush Mount Concentric Duct Kit w/ Filter CDK36530 Step Down Concentric Duct Kit CDK36535 Step Down Concentric Duct Kit w/ Filter CDK4872 Flush Mount Concentric Duct Kit CDK4872515 Flush Mount Concentric Duct Kit w/ Filter CDK4872530 Step Down Concentric Duct Kit CDK4872535 Step Down Concentric Duct Kit w/ Filter NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. 10 GPH13[24-60]M41* BLOWER PERFORMANCE DATA Speed Low 230 Med 230 High 230 Low 230 Med 230 High 230 Low 230 Med 230 High 230 Low 230 Med 230 High 230 T1 (G) 230 T2 / T3 (W 2) 230 T4 / T5 (Y) 230 T1 (G) 230 T2 / T3 W2 230 T4 / T5 Y 230 GPH1360M41* GPH1348M41* GPH1342M41* GPH1336M41* GPH1330M41* Model GPH1324M41* Dry Coil Data Volts E.S.P (In. of H 2O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS 667 153 897 233 1242 373 1097 337 1253 397 596 150 841 229 1181 364 1059 330 1204 388 --------------784 224 1122 354 1016 324 1148 379 --------------713 217 1057 344 959 315 1097 369 --------------610 207 982 333 901 305 1033 356 ----- ------- ------- ------- --883 318 818 290 952 342 ----- ------- ------- ------- --719 298 648 271 777 313 --- ------- ------- ------- ----617 284 562 257 670 297 CFM WATTS CFM WATTS 1448 499 1122 338 1380 483 1078 330 1323 472 1032 321 1258 459 972 310 1194 446 915 300 1106 427 804 283 1008 410 687 264 864 382 558 250 CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM 1387 456 1521 534 1122 338 1387 456 1521 534 1,440 1331 440 1454 521 1078 330 1331 440 1454 521 1,395 1264 428 1388 510 1032 321 1264 428 1388 510 1,360 1209 412 1311 490 972 310 1209 412 1311 490 1,310 1119 399 1230 477 915 300 1119 399 1230 477 1,265 1041 382 1144 461 804 283 1041 382 1144 461 1,235 935 363 1055 442 687 264 935 363 1055 442 1,190 748 330 939 420 558 250 748 330 939 420 1,130 275 1,795 475 1,860 285 1,765 490 1,820 295 1,715 505 1,785 315 1,695 520 1,745 325 1,650 530 1,700 335 1,600 535 1,625 345 1,500 510 1,515 355 1,375 475 1,395 515 1,755 420 1,850 480 2,180 770 530 1,720 435 1,820 500 2,125 755 545 1,685 455 1,775 515 2,050 725 565 1,645 460 1,735 525 1,975 700 570 1,615 475 1,705 535 1,875 675 550 1,570 490 1,675 555 1,800 640 535 1,530 500 1,610 545 1,655 575 485 1,465 500 1,495 520 1,530 540 WATTS CFM WATTS CFM WATTS CFM WATTS NOTES: • • • • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H2O, for 2 row indoor coil; 0.2” H2O, for 3 row indoor coil; and 0.3” H2O, for 4 row indoor coil. Data shown does not include filter pressure drop, approx. 0.08” H2O. ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON. Reduce airflow by 2% for 208V operation. 11 12 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 BTU OUTPUT vs TEMPERATURE RISE CHART 150 BLOWER PERFORMANCE DATA TEMPERATURE RISE EXPANDED PERFORMANCE DATA * 75 70 22.8 0.74 19 1.68 7.3 229 111 21.1 0.71 19 1.64 7.1 222 108 23.9 0.88 21 1.71 7.4 233 114 23.2 0.84 22 1.70 7.4 231 113 21.4 0.81 22 1.66 7.2 224 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 825 723 22.1 0.72 20 1.69 7.3 241 116 24.6 0.78 19 1.74 7.6 251 121 23.9 0.75 20 1.73 7.5 249 120 21.8 0.59 16 1.68 7.3 239 115 23.7 0.61 16 1.72 7.4 246 119 24.4 0.64 16 1.73 7.5 249 120 23.9 0.55 17 1.74 7.5 255 127 26.7 0.59 16 1.79 7.7 265 132 25.9 0.57 16 1.78 7.7 263 131 23.9 0.41 12 1.73 7.5 252 126 25.9 0.43 12 1.77 7.6 260 129 26.7 0.45 12 1.78 7.7 263 131 25.6 0.35 11 1.79 7.7 266 135 28.6 0.38 11 1.85 8.0 277 141 27.8 0.36 11 1.83 7.9 274 139 - - - 20.9 0.84 22 1.78 7.7 252 115 23.4 0.91 21 1.83 7.9 262 120 22.7 0.87 22 1.82 7.8 259 119 20.6 0.73 19 1.76 7.6 249 114 22.3 0.76 19 1.80 7.8 257 118 23.0 0.80 18 1.82 7.8 259 119 21.6 0.75 20 1.81 7.8 271 123 24.1 0.81 19 1.87 8.0 282 128 23.4 0.77 20 1.85 8.0 279 127 21.3 0.61 17 1.80 7.7 268 122 23.1 0.64 16 1.84 7.9 276 125 23.8 0.67 16 1.85 8.0 279 127 23.3 0.57 17 1.87 8.0 286 134 26.0 0.61 16 1.93 8.3 298 140 25.3 0.59 17 1.91 8.2 295 138 23.4 0.43 13 1.85 8.0 283 133 25.3 0.44 12 1.90 8.1 292 137 26.1 0.46 12 1.91 8.2 295 138 25.0 0.36 12 1.92 8.3 298 143 27.9 0.40 11 1.99 8.5 310 149 27.1 0.38 11 1.97 8.4 307 147 - - - 20.4 0.86 22 1.88 8.2 286 120 22.8 0.93 21 1.94 8.4 298 125 22.1 0.89 22 1.93 8.4 295 124 20.1 0.75 19 1.87 8.1 283 119 21.8 0.78 19 1.91 8.3 292 122 22.4 0.82 18 1.93 8.4 295 124 21.0 0.77 21 1.92 8.4 308 128 23.5 0.83 19 1.98 8.6 321 133 22.8 0.79 20 1.97 8.5 317 132 20.8 0.63 17 1.90 8.3 305 126 22.6 0.65 16 1.95 8.5 314 130 23.2 0.68 16 1.97 8.5 317 132 22.8 0.58 17 1.98 8.6 325 139 25.4 0.63 16 2.04 8.8 338 145 24.7 0.60 17 2.03 8.8 335 144 22.8 0.44 13 1.96 8.5 322 138 24.7 0.45 12 2.01 8.7 332 142 25.5 0.47 12 2.03 8.8 335 144 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 723 825 927 927 23.5 0.77 18 1.69 7.4 231 113 MBh S/T Delta T KW AMPS HI PR LO PR 24.4 0.37 12 2.04 8.8 339 148 27.3 0.41 11 2.11 9.1 353 154 26.5 0.39 11 2.09 9.1 350 153 - - - 19.9 0.88 22 1.97 8.6 326 126 22.2 0.96 21 2.04 8.9 339 131 21.6 0.92 22 2.02 8.8 336 130 19.6 0.78 19 1.96 8.6 323 125 21.2 0.81 19 2.00 8.8 333 129 21.9 0.85 18 2.02 8.8 336 130 20.5 0.79 21 2.01 8.8 351 134 22.9 0.86 20 2.08 9.1 365 140 22.2 0.82 20 2.06 9.0 361 138 20.3 0.65 17 2.00 8.8 347 133 22.0 0.67 17 2.05 9.0 358 137 22.7 0.71 16 2.06 9.0 361 138 22.2 0.60 17 2.08 9.1 370 146 24.8 0.65 16 2.14 9.4 386 152 24.1 0.62 17 2.13 9.3 382 151 22.3 0.45 13 2.06 9.0 367 145 24.1 0.47 13 2.11 9.2 378 149 24.8 0.49 12 2.13 9.3 382 151 18.9 0.92 22 2.05 9.1 367 132 21.1 1.00 21 2.12 9.4 382 138 20.5 0.95 22 2.10 9.3 378 136 18.6 0.81 19 2.04 9.0 363 131 20.2 0.84 19 2.09 9.2 374 135 20.8 0.88 18 2.10 9.3 378 136 19.5 0.82 20 2.10 9.3 394 140 21.8 0.89 19 2.16 9.6 411 146 21.1 0.85 20 2.15 9.5 407 145 19.3 0.67 17 2.08 9.2 390 139 20.9 0.70 16 2.13 9.4 403 143 21.5 0.73 16 2.15 9.5 407 145 21.1 0.62 17 2.16 9.6 417 153 23.6 0.68 16 2.23 9.9 434 160 22.9 0.64 16 2.21 9.8 429 158 21.1 0.47 13 2.14 9.5 412 152 22.9 0.48 12 2.20 9.7 425 157 23.6 0.51 12 2.21 9.8 429 158 22.7 0.40 12 2.23 9.9 434 163 25.3 0.43 11 2.30 10.2 452 170 24.5 0.41 11 2.29 10.1 448 168 - - - 17.5 0.93 21 2.12 9.6 405 137 19.6 1.00 19 2.19 9.9 422 142 19.0 0.96 20 2.17 9.8 418 141 17.3 0.81 18 2.10 9.5 401 135 18.7 0.84 18 2.15 9.7 413 139 19.3 0.89 17 2.17 9.8 417 141 63 18.1 0.83 19 2.16 9.8 436 145 20.2 0.90 18 2.24 10.1 454 151 19.6 0.86 19 2.22 10.0 449 150 17.9 0.68 15 2.15 9.7 431 144 19.4 0.71 15 2.20 9.9 445 148 20.0 0.74 15 2.22 10.0 449 150 67 19.6 0.63 16 2.23 10.0 460 159 21.8 0.68 15 2.31 10.4 479 165 21.2 0.65 15 2.29 10.3 474 164 19.6 0.47 12 2.22 10.0 456 157 21.2 0.49 12 2.27 10.2 470 162 21.9 0.51 11 2.29 10.3 474 164 21.0 0.40 11 2.31 10.4 480 169 23.4 0.44 10 2.38 10.7 500 176 22.7 0.42 11 2.36 10.6 495 174 - - - 71 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 23.8 0.39 12 2.14 9.4 386 156 26.6 0.42 11 2.21 9.7 402 162 25.8 0.40 11 2.20 9.6 398 161 - - - 115 COOLING OPERATION Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MODEL: GPH1324M41* COOLING PERFORMANCE DATA GPH1324M41* 13 14 EXPANDED PERFORMANCE DATA * 85 24.0 0.96 26 1.72 7.5 236 115 22.2 0.93 26 1.68 7.3 229 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 825 723 22.6 0.89 26 1.72 7.4 246 119 24.5 0.93 25 1.76 7.6 254 122 25.2 0.97 24 1.77 7.7 256 123 23.7 0.81 24 1.77 7.6 260 129 25.7 0.84 24 1.81 7.8 268 133 26.4 0.88 23 1.82 7.9 271 135 25.3 0.65 21 1.82 7.9 271 138 27.4 0.68 21 1.86 8.0 279 142 28.2 0.71 20 1.88 8.1 282 144 21.7 0.96 26 1.80 7.8 257 118 23.5 1.00 26 1.85 7.9 265 121 24.2 1.00 24 1.86 8.0 267 123 22.1 0.93 26 1.84 7.9 276 125 23.9 0.96 26 1.88 8.1 285 129 24.7 1.00 24 1.90 8.2 288 130 23.1 0.84 25 1.90 8.1 292 137 25.1 0.87 24 1.94 8.3 301 141 25.8 0.91 23 1.96 8.4 304 142 24.7 0.68 21 1.95 8.4 304 146 26.8 0.70 21 2.00 8.6 314 150 27.6 0.74 20 2.02 8.6 317 152 21.2 0.98 27 1.91 8.3 292 122 22.9 1.00 26 1.96 8.5 301 126 23.6 1.00 23 1.97 8.6 304 127 21.6 0.95 26 1.95 8.5 314 130 23.4 0.99 26 2.00 8.7 324 134 24.1 1.00 24 2.01 8.7 327 136 22.6 0.86 25 2.01 8.7 332 142 24.5 0.89 24 2.06 8.9 342 147 25.2 0.93 23 2.07 9.0 345 148 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 927 24.8 1.00 25 1.73 7.5 238 116 MBh S/T Delta T KW AMPS HI PR LO PR 24.1 0.70 21 2.07 9.0 346 151 26.1 0.72 21 2.12 9.2 357 156 26.9 0.76 20 2.14 9.3 360 158 20.6 1.00 26 2.00 8.8 332 129 22.4 1.00 25 2.05 9.0 343 133 23.0 1.00 23 2.07 9.1 346 134 21.0 0.98 26 2.05 9.0 358 137 22.8 1.00 25 2.10 9.2 369 141 23.5 1.00 23 2.11 9.2 372 142 22.0 0.89 25 2.11 9.2 378 149 23.9 0.92 24 2.16 9.4 389 154 24.6 0.96 23 2.18 9.5 393 155 19.6 1.00 25 2.08 9.2 374 135 21.2 1.00 24 2.14 9.5 386 139 21.9 1.00 22 2.15 9.5 389 140 20.0 1.00 25 2.13 9.4 402 143 21.7 1.00 24 2.18 9.7 415 148 22.3 1.00 22 2.20 9.7 419 149 20.9 0.92 24 2.20 9.7 425 156 22.7 0.95 24 2.25 9.9 438 161 23.4 1.00 23 2.27 10.0 442 163 22.3 0.75 21 2.27 10.0 443 167 24.2 0.77 21 2.32 10.3 457 172 24.9 0.81 20 2.34 10.3 462 174 18.2 1.00 23 2.15 9.7 413 139 19.7 1.00 22 2.21 9.9 426 144 20.3 1.00 20 2.22 10.0 430 145 18.5 1.00 24 2.20 9.9 445 148 20.1 1.00 22 2.25 10.2 458 153 20.7 1.00 20 2.27 10.2 463 154 19.4 0.93 23 2.27 10.2 470 162 21.0 0.96 23 2.33 10.4 484 167 21.6 1.00 21 2.35 10.5 489 169 67 21.8 0.84 18 2.33 10.4 484 167 21.1 0.80 19 2.31 10.4 479 165 19.5 0.77 19 2.25 10.1 465 160 20.7 0.75 20 2.34 10.5 490 172 22.4 0.78 19 2.40 10.8 505 178 23.1 0.82 19 2.42 10.9 510 179 71 23.3 0.63 15 2.40 10.8 505 178 22.6 0.60 15 2.38 10.7 500 176 20.8 0.58 15 2.32 10.4 485 171 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 23.5 0.72 21 2.18 9.5 394 159 25.5 0.74 21 2.23 9.7 406 164 26.2 0.78 20 2.25 9.8 410 166 63 20.4 1.00 20 2.25 10.2 458 153 19.8 0.99 22 2.24 10.1 454 151 18.2 0.95 22 2.18 9.8 440 147 115 COOLING OPERATION Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2 23.7 25.3 27.1 22.6 23.1 24.7 26.4 21.5 22.0 23.5 25.1 19.9 S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.84 0.62 1.00 Delta T 23 22 19 15 24 23 20 16 23 23 20 16 22 23 20 16 21 22 19 16 20 927 KW 1.72 1.76 1.81 1.86 1.85 1.88 1.94 2.00 1.96 2.00 2.06 2.12 2.05 2.10 2.16 2.23 2.14 2.18 2.25 2.32 2.21 AMPS 7.5 7.6 7.8 8.0 7.9 8.1 8.3 8.6 8.5 8.7 8.9 9.2 9.0 9.2 9.4 9.7 9.5 9.7 9.9 10.3 9.9 HI PR 236 254 268 279 265 285 301 314 301 324 342 357 343 369 389 406 386 415 438 457 426 LO PR 115 122 133 142 121 129 141 150 126 134 147 156 133 141 154 164 139 148 161 172 144 MBh 23.6 24.1 25.8 27.6 23.1 23.6 25.2 26.9 22.5 23.0 24.6 26.3 22.0 22.5 25.7 20.9 21.3 22.8 24.4 19.3 24.0 S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 0.97 0.91 0.74 0.56 1.00 0.94 0.57 1.00 0.98 0.80 0.60 1.00 0.77 Delta T 24 23 20 16 24 23 20 16 24 23 20 16 24 24 16 23 23 20 16 22 21 2.15 80 825 KW 1.71 1.74 1.79 1.85 1.83 1.87 1.93 1.99 1.94 1.98 2.04 2.11 2.04 2.08 2.21 2.12 2.16 2.23 2.30 2.19 9.4 AMPS 7.4 7.6 7.7 8.0 7.9 8.0 8.3 8.5 8.4 8.6 8.8 9.1 8.9 9.1 9.7 9.4 9.6 9.9 10.2 9.9 HI PR 233 251 265 277 262 282 298 310 298 321 339 353 339 365 402 382 411 434 452 422 386 LO PR 114 121 132 141 120 128 140 149 125 133 145 155 131 140 162 138 146 160 170 142 152 MBh 21.8 22.3 23.8 25.5 21.3 21.8 23.3 24.9 20.8 21.3 22.7 24.3 20.3 20.7 22.2 23.7 19.3 19.7 21.0 22.5 17.9 S/T 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.01 0.94 0.77 0.57 1.01 Delta T 25 24 20 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 16 23 723 KW 1.67 1.70 1.75 1.81 1.79 1.83 1.88 1.94 1.90 1.93 1.99 2.06 1.99 2.03 2.09 2.16 2.07 2.11 2.18 2.25 2.14 AMPS 7.3 7.4 7.6 7.8 7.7 7.9 8.1 8.3 8.3 8.4 8.6 8.9 8.7 8.9 9.1 9.4 9.2 9.4 9.6 9.9 9.6 HI PR 226 244 257 268 254 273 289 301 289 311 328 342 329 354 374 390 370 398 421 439 409 LO PR 110 117 128 136 117 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 MODEL: GPH1324M41* COOLING PERFORMANCE DATA GPH1324M41* EXPANDED PERFORMANCE DATA * 75 70 27.6 0.74 18 2.18 9.4 229 108 25.5 0.71 18 2.14 9.2 223 105 28.9 0.88 20 2.22 9.6 234 110 28.1 0.84 21 2.20 9.5 232 109 25.9 0.81 21 2.15 9.3 225 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1050 920 1180 28.9 0.75 19 2.24 9.7 249 116 26.7 0.72 19 2.19 9.5 242 112 29.8 0.78 18 2.26 9.8 252 117 26.4 0.59 16 2.18 9.4 240 111 28.6 0.61 15 2.23 9.6 247 115 29.5 0.64 15 2.24 9.7 249 116 31.3 0.57 15 2.31 9.9 263 126 28.9 0.55 16 2.26 9.7 256 123 32.2 0.59 15 2.33 10.0 266 128 28.9 0.41 12 2.24 9.7 253 121 31.3 0.43 12 2.29 9.9 261 125 32.3 0.45 11 2.31 9.9 263 126 33.6 0.36 11 2.38 10.3 275 135 31.0 0.35 11 2.33 10.0 267 131 34.6 0.38 10 2.40 10.3 277 136 - - - 27.4 0.87 21 2.36 10.1 260 115 25.3 0.83 21 2.31 9.9 252 112 28.2 0.91 20 2.38 10.2 263 116 24.9 0.73 18 2.29 9.8 250 110 26.9 0.76 18 2.34 10.1 257 114 27.8 0.80 17 2.36 10.1 260 115 28.2 0.77 19 2.41 10.3 280 122 26.0 0.75 19 2.35 10.1 272 119 29.1 0.81 18 2.43 10.4 283 124 25.8 0.61 16 2.33 10.0 269 117 27.9 0.64 16 2.39 10.3 277 121 28.8 0.67 15 2.41 10.3 280 122 30.5 0.59 16 2.48 10.6 296 134 28.2 0.57 16 2.42 10.4 287 130 31.5 0.61 15 2.50 10.7 299 135 28.2 0.42 12 2.41 10.3 284 128 30.6 0.44 12 2.46 10.5 293 132 31.5 0.46 11 2.48 10.6 296 134 32.8 0.38 11 2.56 10.9 308 142 30.3 0.36 11 2.50 10.7 299 138 33.8 0.40 10 2.58 11.0 311 144 - - - 26.8 0.89 21 2.50 10.9 296 120 24.7 0.86 21 2.44 10.6 287 116 27.6 0.93 20 2.52 10.9 299 121 24.3 0.75 18 2.42 10.5 284 115 26.3 0.78 18 2.48 10.8 293 118 27.1 0.82 17 2.50 10.9 296 120 27.5 0.79 19 2.55 11.1 318 127 25.4 0.77 19 2.49 10.8 309 123 28.4 0.83 18 2.57 11.2 322 128 25.2 0.63 16 2.47 10.7 306 122 27.3 0.65 16 2.53 11.0 315 126 28.1 0.68 15 2.55 11.1 318 127 29.8 0.60 16 2.63 11.4 336 139 27.5 0.58 16 2.57 11.1 326 135 30.7 0.63 15 2.65 11.5 340 140 27.6 0.44 12 2.55 11.0 323 133 29.9 0.45 12 2.61 11.3 333 137 30.8 0.47 11 2.63 11.4 336 139 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 920 1050 1180 28.4 0.77 17 2.20 9.5 232 109 MBh S/T Delta T KW AMPS HI PR LO PR 32.0 0.39 11 2.72 11.7 351 148 29.5 0.37 11 2.65 11.5 340 143 33.0 0.41 10 2.74 11.8 354 149 - - - 26.1 0.92 21 2.63 11.5 337 126 24.1 0.88 21 2.56 11.2 327 122 26.9 0.96 20 2.65 11.6 340 127 23.7 0.78 18 2.54 11.1 324 121 25.7 0.81 18 2.60 11.4 334 124 26.4 0.85 17 2.63 11.5 337 126 24.8 0.79 20 2.62 11.4 352 130 26.9 0.82 19 2.68 11.7 363 134 27.7 0.86 19 2.70 11.8 366 135 24.6 0.65 16 2.60 11.4 348 128 26.6 0.67 16 2.66 11.6 359 132 27.4 0.71 15 2.68 11.7 363 134 29.1 0.62 16 2.76 12.0 383 146 26.8 0.60 16 2.70 11.8 371 141 30.0 0.65 15 2.79 12.1 387 147 26.9 0.45 12 2.68 11.7 368 140 29.1 0.47 12 2.74 12.0 379 144 30.0 0.49 11 2.76 12.0 383 146 24.8 0.95 21 2.73 12.1 379 132 22.9 0.92 21 2.67 11.8 368 128 25.5 1.00 20 2.75 12.2 383 133 22.5 0.81 18 2.64 11.7 364 126 24.4 0.84 18 2.71 12.0 375 130 25.1 0.88 17 2.73 12.1 379 132 25.5 0.85 19 2.79 12.4 408 140 23.6 0.82 19 2.72 12.1 396 136 26.3 0.89 18 2.81 12.5 412 141 23.3 0.67 16 2.70 12.0 392 134 25.3 0.70 15 2.77 12.3 404 139 26.0 0.73 15 2.79 12.4 408 140 27.6 0.64 16 2.88 12.7 431 153 25.5 0.62 16 2.81 12.4 418 148 28.5 0.68 15 2.90 12.8 435 154 25.6 0.47 12 2.78 12.3 414 147 27.7 0.48 12 2.85 12.6 426 151 28.5 0.51 11 2.88 12.7 431 153 29.7 0.41 11 2.97 13.1 449 163 27.4 0.40 11 2.90 12.8 436 158 30.5 0.43 10 2.99 13.2 454 164 - - - 23.0 0.96 19 2.82 12.7 419 136 21.2 0.92 20 2.75 12.4 406 132 23.7 1.00 18 2.84 12.8 423 137 20.8 0.81 17 2.73 12.3 402 131 22.6 0.84 17 2.80 12.6 415 135 23.3 0.88 16 2.82 12.7 419 136 63 23.6 0.86 18 2.88 13.0 451 145 21.8 0.83 18 2.81 12.7 437 140 24.4 0.90 17 2.91 13.1 455 146 21.6 0.68 15 2.79 12.6 433 139 23.4 0.70 14 2.86 12.9 446 143 24.1 0.74 14 2.88 13.0 451 145 67 25.6 0.65 15 2.97 13.4 476 158 23.6 0.63 15 2.90 13.0 462 153 26.4 0.68 14 3.00 13.5 481 160 23.7 0.47 11 2.88 12.9 457 152 25.6 0.49 11 2.95 13.3 471 156 26.4 0.51 11 2.97 13.4 476 158 27.5 0.42 10 3.07 13.8 496 168 25.4 0.40 10 3.00 13.5 481 163 28.3 0.44 10 3.10 13.9 501 170 - - - 71 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 31.2 0.40 11 2.85 12.4 399 155 28.8 0.38 11 2.78 12.1 387 151 32.2 0.42 10 2.88 12.5 403 157 - - - 115 COOLING OPERATION Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MODEL: GPH1330M41* COOLING PERFORMANCE DATA GPH1330M41* 15 16 EXPANDED PERFORMANCE DATA * 85 29.9 1.00 23 2.25 9.7 239 112 29.1 0.96 24 2.23 9.6 236 111 26.8 0.93 25 2.18 9.4 229 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 920 1180 29.6 0.93 24 2.28 9.8 255 118 27.3 0.89 24 2.23 9.6 247 115 30.5 0.97 23 2.30 9.9 257 119 26.9 0.83 22 2.21 9.5 244 113 31.0 0.84 23 2.35 10.1 269 129 28.6 0.81 23 2.29 9.9 261 125 31.9 0.88 22 2.37 10.2 271 130 28.8 0.67 19 2.28 9.8 258 124 33.1 0.68 20 2.42 10.4 280 137 30.5 0.65 20 2.36 10.2 272 133 34.1 0.71 19 2.44 10.5 283 139 30.8 0.50 15 2.34 10.1 269 132 28.4 1.00 25 2.40 10.3 265 117 26.2 0.96 25 2.34 10.0 257 114 29.2 1.00 23 2.42 10.4 268 119 25.7 0.92 24 2.32 10.0 255 113 28.9 0.96 24 2.45 10.5 286 125 26.7 0.93 25 2.39 10.2 277 121 29.8 1.00 23 2.46 10.6 288 126 26.3 0.86 23 2.37 10.2 274 120 30.3 0.87 23 2.52 10.8 302 136 28.0 0.84 23 2.46 10.5 293 132 31.2 0.91 22 2.54 10.9 305 138 28.1 0.70 20 2.44 10.5 290 131 32.3 0.70 20 2.60 11.1 315 145 29.8 0.68 20 2.54 10.9 305 141 33.3 0.74 19 2.62 11.2 318 147 30.0 0.52 16 2.52 10.8 302 139 27.7 1.00 24 2.54 11.0 302 122 25.6 0.98 25 2.48 10.8 293 118 28.5 1.00 22 2.56 11.1 305 123 25.1 0.94 24 2.46 10.7 290 117 28.2 0.99 24 2.59 11.2 325 130 26.1 0.95 25 2.53 11.0 315 126 29.1 1.00 23 2.61 11.3 328 131 25.7 0.88 23 2.51 10.9 312 125 29.6 0.89 23 2.67 11.6 343 142 27.3 0.86 23 2.61 11.3 333 137 30.5 0.93 22 2.70 11.7 346 143 27.4 0.72 20 2.59 11.2 329 136 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 920 1050 26.4 0.88 23 2.17 9.4 227 107 MBh S/T Delta T KW AMPS HI PR LO PR 31.6 0.72 20 2.76 11.9 358 151 29.1 0.70 20 2.69 11.7 347 146 32.5 0.76 19 2.78 12.0 361 152 29.3 0.54 16 2.67 11.6 344 145 27.0 1.00 24 2.67 11.7 344 128 24.9 1.00 25 2.60 11.4 333 124 27.8 1.00 22 2.69 11.8 347 129 24.5 0.97 24 2.58 11.3 330 123 27.6 1.00 24 2.72 11.9 370 136 25.4 0.98 25 2.66 11.6 359 132 28.4 1.00 22 2.75 12.0 374 138 25.1 0.91 23 2.64 11.5 355 131 28.9 0.92 23 2.81 12.2 391 149 26.6 0.88 24 2.74 12.0 379 144 29.7 0.96 22 2.83 12.3 395 150 26.8 0.74 20 2.72 11.9 375 143 25.7 1.00 22 2.78 12.3 387 134 23.7 1.00 24 2.71 12.0 375 130 26.4 1.00 21 2.80 12.4 391 136 23.3 1.01 23 2.69 11.9 371 129 26.2 1.00 23 2.83 12.6 416 143 24.2 1.00 24 2.77 12.3 404 139 27.0 1.00 21 2.86 12.7 420 144 23.8 0.94 22 2.74 12.2 400 137 27.4 0.95 23 2.92 12.9 439 156 25.3 0.92 23 2.85 12.6 426 151 28.2 1.00 22 2.95 13.0 444 157 25.4 0.77 20 2.83 12.5 422 150 29.2 0.77 20 3.02 13.3 458 166 27.0 0.75 20 2.95 13.0 445 161 30.1 0.81 19 3.04 13.5 463 168 27.2 0.57 16 2.92 12.9 440 159 23.8 1.00 21 2.87 12.9 427 139 22.0 1.00 22 2.80 12.6 414 135 24.5 1.00 19 2.89 13.0 432 140 21.6 1.01 22 2.78 12.5 410 133 24.2 1.00 21 2.93 13.2 460 148 22.4 1.00 22 2.86 12.9 446 143 25.0 1.00 19 2.95 13.3 464 149 22.0 0.95 21 2.84 12.8 442 142 25.4 0.96 21 3.02 13.6 486 161 23.4 0.93 22 2.95 13.3 471 156 26.2 1.00 20 3.05 13.7 490 163 23.6 0.77 18 2.93 13.2 466 155 67 26.3 0.84 17 3.02 13.6 486 161 25.5 0.80 18 3.00 13.5 481 160 27.1 0.78 18 3.12 14.0 506 172 25.0 0.75 19 3.05 13.7 491 167 27.9 0.82 18 3.15 14.2 511 173 25.2 0.58 15 3.02 13.6 486 165 71 28.1 0.63 14 3.12 14.0 506 172 27.3 0.60 14 3.10 13.9 501 170 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 30.8 0.74 20 2.90 12.6 407 158 28.4 0.72 20 2.83 12.3 395 154 31.7 0.78 19 2.92 12.7 411 160 28.6 0.55 16 2.81 12.2 391 152 63 24.6 1.00 19 2.93 13.2 460 148 23.9 0.99 21 2.91 13.1 455 146 115 COOLING OPERATION Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 29.4 30.1 32.1 34.3 28.7 29.4 31.4 33.5 28.0 28.7 30.6 32.7 27.4 28.0 29.9 31.9 26.0 26.6 28.4 30.3 24.1 S/T 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 Delta T 22 21 18 15 22 21 19 15 22 21 19 15 21 22 19 15 20 21 18 15 19 1180 KW 2.23 2.28 2.35 2.42 2.40 2.45 2.52 2.60 2.54 2.59 2.67 2.76 2.67 2.72 2.81 2.90 2.78 2.83 2.92 3.02 2.87 AMPS 9.6 9.8 10.1 10.4 10.3 10.5 10.8 11.1 11.0 11.2 11.6 11.9 11.7 11.9 12.2 12.6 12.3 12.6 12.9 13.3 12.9 HI PR 236 255 269 280 265 286 302 315 302 325 343 358 344 370 391 407 387 416 439 458 427 LO PR 111 118 129 137 117 125 136 145 122 130 142 151 128 136 149 158 134 143 156 166 139 MBh 28.6 29.2 31.2 33.3 27.9 28.5 30.5 32.6 27.2 27.8 29.7 31.8 26.6 27.1 31.0 25.2 25.8 27.6 29.5 23.4 29.0 S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.56 1.00 0.94 0.57 1.00 0.98 0.80 0.60 1.00 0.77 Delta T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 16 22 22 19 15 20 19 2.79 80 1050 KW 2.22 2.26 2.33 2.40 2.38 2.43 2.50 2.58 2.52 2.57 2.65 2.74 2.65 2.70 2.88 2.75 2.81 2.90 2.99 2.85 12.1 AMPS 9.6 9.8 10.0 10.3 10.2 10.4 10.7 11.0 10.9 11.2 11.5 11.8 11.6 11.8 12.5 12.2 12.5 12.8 13.2 12.8 HI PR 234 252 266 278 263 283 299 311 299 322 340 354 340 366 403 383 412 435 454 423 387 LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 157 133 141 154 164 137 147 MODEL: GPH1330M41* COOLING PERFORMANCE DATA GPH1330M41* EXPANDED PERFORMANCE DATA * 75 70 32.9 0.70 19 2.50 10.5 235 111 30.4 0.68 19 2.45 10.3 228 107 34.5 0.84 21 2.54 10.7 240 113 33.5 0.80 21 2.52 10.6 237 112 30.9 0.77 22 2.46 10.3 230 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1150 1008 1292 1150 1008 31.8 0.69 20 2.51 10.5 248 115 34.5 0.72 20 2.57 10.8 255 119 35.5 0.75 19 2.59 10.9 258 120 31.5 0.57 16 2.49 10.5 245 114 34.1 0.59 16 2.55 10.7 253 118 35.1 0.62 15 2.57 10.8 255 119 34.4 0.52 16 2.59 10.8 262 126 37.3 0.54 16 2.65 11.1 270 130 38.4 0.57 16 2.67 11.2 272 131 34.5 0.39 12 2.57 10.8 259 125 37.4 0.41 12 2.63 11.0 267 129 38.5 0.43 12 2.65 11.1 270 130 37.0 0.34 11 2.67 11.2 273 134 40.0 0.35 11 2.73 11.4 281 138 41.2 0.37 11 2.75 11.5 284 140 - - - 30.2 0.80 22 2.64 11.0 258 115 32.7 0.83 22 2.70 11.3 266 118 33.7 0.87 21 2.72 11.4 269 119 29.7 0.70 19 2.62 11.0 256 113 32.2 0.73 19 2.68 11.2 264 117 33.1 0.76 18 2.70 11.3 266 118 31.1 0.71 20 2.70 11.3 278 122 33.7 0.74 20 2.76 11.5 287 126 34.7 0.78 19 2.78 11.6 289 127 30.8 0.59 16 2.67 11.2 275 121 33.3 0.61 16 2.74 11.4 284 124 34.3 0.64 16 2.76 11.5 287 126 33.6 0.54 17 2.78 11.6 294 133 36.4 0.56 16 2.84 11.9 303 137 37.5 0.59 16 2.86 12.0 306 139 33.7 0.41 13 2.75 11.5 291 132 36.5 0.42 12 2.82 11.8 300 136 37.6 0.44 12 2.84 11.9 303 137 36.1 0.35 11 2.86 11.9 306 142 39.1 0.36 11 2.93 12.2 316 146 40.3 0.38 11 2.95 12.3 319 148 - - - 29.5 0.82 22 2.80 11.8 294 119 31.9 0.85 22 2.86 12.1 303 123 32.9 0.89 21 2.89 12.2 306 124 29.0 0.72 19 2.78 11.8 291 118 31.4 0.75 19 2.84 12.0 300 122 32.3 0.78 18 2.86 12.1 303 123 30.3 0.73 20 2.86 12.1 316 127 32.9 0.76 20 2.92 12.4 326 131 33.8 0.80 19 2.95 12.5 329 132 30.0 0.60 16 2.83 12.0 313 125 32.5 0.62 16 2.90 12.3 323 129 33.5 0.65 16 2.92 12.4 326 131 32.8 0.55 17 2.94 12.4 334 138 35.6 0.58 16 3.01 12.7 344 143 36.6 0.60 16 3.04 12.8 348 144 32.9 0.42 13 2.92 12.3 330 137 35.6 0.43 12 2.99 12.6 341 141 36.7 0.45 12 3.01 12.7 344 143 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 1292 33.9 0.74 18 2.52 10.6 237 112 MBh S/T Delta T KW AMPS HI PR LO PR 35.2 0.36 11 3.04 12.8 348 147 38.2 0.37 11 3.11 13.2 359 152 39.3 0.39 11 3.13 13.3 363 153 - - - 28.7 0.85 22 2.94 12.5 335 125 31.1 0.88 22 3.01 12.9 345 129 32.1 0.92 21 3.03 13.0 348 130 28.3 0.74 19 2.91 12.4 331 124 30.6 0.77 19 2.98 12.8 341 128 31.5 0.81 18 3.01 12.9 345 129 29.6 0.76 20 3.00 12.8 360 133 32.1 0.78 20 3.07 13.1 371 137 33.0 0.82 19 3.09 13.2 375 139 29.3 0.62 17 2.97 12.7 356 132 31.7 0.64 16 3.05 13.0 367 136 32.7 0.68 16 3.07 13.1 371 137 32.0 0.57 17 3.09 13.2 380 145 34.7 0.59 16 3.17 13.5 392 150 35.7 0.62 16 3.19 13.6 396 151 32.1 0.43 13 3.07 13.1 376 144 34.8 0.45 12 3.14 13.4 388 148 35.8 0.47 12 3.17 13.5 392 150 27.3 0.88 22 3.05 13.2 376 131 29.6 0.91 22 3.13 13.6 388 135 30.5 0.95 21 3.15 13.7 392 137 26.9 0.77 19 3.03 13.1 373 130 29.1 0.80 19 3.10 13.5 384 134 30.0 0.84 18 3.13 13.6 388 135 28.1 0.79 20 3.12 13.5 405 139 30.5 0.81 20 3.19 13.9 418 144 31.4 0.85 19 3.22 14.0 422 145 27.8 0.65 16 3.09 13.4 401 138 30.2 0.67 16 3.17 13.8 413 142 31.1 0.70 15 3.19 13.9 418 144 30.4 0.59 16 3.22 13.9 428 152 33.0 0.62 16 3.30 14.3 441 157 34.0 0.65 16 3.32 14.4 445 159 30.5 0.45 12 3.19 13.8 423 151 33.0 0.46 12 3.27 14.2 437 155 34.0 0.49 12 3.29 14.3 441 157 32.7 0.38 11 3.32 14.4 446 162 35.4 0.40 11 3.40 14.8 460 167 36.4 0.42 11 3.43 14.9 465 169 - - - 25.3 0.89 20 3.15 13.9 416 136 27.4 0.92 20 3.23 14.3 429 140 28.2 0.96 19 3.26 14.4 433 141 24.9 0.78 18 3.13 13.8 412 134 26.9 0.81 17 3.21 14.2 424 138 27.8 0.85 17 3.23 14.3 429 140 63 26.0 0.79 19 3.22 14.2 448 144 28.2 0.82 19 3.30 14.6 461 149 29.1 0.86 18 3.33 14.7 466 150 25.8 0.65 15 3.20 14.1 443 143 27.9 0.67 15 3.27 14.5 457 147 28.8 0.71 14 3.30 14.6 461 149 67 28.2 0.60 15 3.32 14.7 473 157 30.5 0.62 15 3.41 15.0 487 162 31.5 0.65 15 3.43 15.2 492 164 28.2 0.45 12 3.30 14.5 468 156 30.6 0.47 11 3.38 14.9 482 161 31.5 0.49 11 3.41 15.0 487 162 30.3 0.39 11 3.43 15.2 493 168 32.8 0.40 10 3.52 15.5 508 173 33.8 0.42 10 3.55 15.7 513 175 - - - 71 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 34.4 0.37 12 3.19 13.6 397 155 37.2 0.38 11 3.27 14.0 409 160 38.4 0.40 11 3.29 14.1 413 161 - - - 115 COOLING OPERATION Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7+/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MODEL: GPH1336M41* COOLING PERFORMANCE DATA GPH1336M41* 17 18 EXPANDED PERFORMANCE DATA * 85 80 37.0 0.80 24 2.69 11.3 275 132 39.5 0.65 21 2.77 11.6 287 141 40.7 0.68 20 2.79 11.7 290 143 33.9 0.95 26 2.75 11.5 272 121 34.9 1.00 25 2.77 11.6 274 122 33.3 0.91 24 2.72 11.4 269 119 30.7 0.88 25 2.66 11.1 261 116 34.5 0.92 25 2.80 11.7 292 128 35.6 0.96 24 2.82 11.8 295 130 34.0 0.85 23 2.78 11.6 289 127 31.4 0.82 24 2.72 11.4 281 123 36.1 0.83 24 2.89 12.0 309 140 37.2 0.87 23 2.91 12.1 312 141 36.3 0.69 20 2.86 12.0 306 139 33.5 0.67 20 2.80 11.7 297 134 38.6 0.67 21 2.98 12.4 322 149 39.7 0.71 20 3.00 12.5 325 151 38.8 0.52 16 2.95 12.3 319 148 35.8 0.50 16 2.88 12.0 309 143 33.1 0.98 26 2.91 12.3 309 125 34.0 1.00 24 2.93 12.4 312 127 32.5 0.93 24 2.89 12.2 306 124 30.0 0.90 25 2.82 11.9 297 120 33.7 0.94 25 2.97 12.6 333 133 34.7 0.99 24 2.99 12.7 336 135 33.2 0.87 23 2.95 12.5 329 132 30.6 0.84 24 2.88 12.2 319 128 35.3 0.85 24 3.06 12.9 351 145 36.3 0.89 23 3.09 13.1 355 147 35.5 0.71 20 3.04 12.8 348 144 32.7 0.69 20 2.97 12.5 337 140 38.8 0.72 20 3.18 13.5 370 156 37.9 0.53 16 3.13 13.3 363 153 35.0 0.51 16 3.06 12.9 352 149 33.2 1.00 24 3.08 13.2 355 133 31.7 0.96 24 3.03 13.0 348 130 29.3 0.93 25 2.96 12.6 338 126 29.8 0.97 26 2.98 12.7 341 128 1150 35.3 0.89 25 2.61 11.0 261 121 38.1 0.84 23 2.71 11.4 278 134 39.8 0.50 16 2.75 11.5 284 140 36.7 0.48 16 2.69 11.3 276 136 MBh 32.0 32.6 34.2 36.4 31.3 31.9 33.4 35.6 30.5 31.1 32.6 34.7 S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.94 0.91 0.82 0.67 Delta T 26 25 24 21 26 26 24 21 26 26 24 21 1008 KW 2.50 2.55 2.63 2.71 2.68 2.74 2.82 2.91 2.84 2.90 2.99 3.08 AMPS 10.5 10.7 11.0 11.4 11.2 11.4 11.8 12.1 12.0 12.3 12.6 13.1 HI PR 235 253 267 278 264 284 299 312 300 323 341 355 LO PR 111 118 129 137 117 124 136 145 121 129 141 150 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 34.7 0.92 25 2.56 10.7 242 114 MBh S/T Delta T KW AMPS HI PR LO PR 36.4 0.93 24 2.63 11.0 263 123 37.2 0.67 20 2.67 11.2 272 131 34.3 0.65 20 2.61 10.9 264 127 32.2 1.00 26 3.05 13.1 352 132 35.7 0.96 24 2.58 10.8 245 115 MBh S/T Delta T KW AMPS HI PR LO PR 34.8 0.82 23 2.59 10.9 258 120 32.1 0.79 23 2.53 10.6 250 117 37.6 0.69 21 3.16 13.4 366 155 1292 1008 1150 34.1 0.88 24 2.54 10.7 240 113 31.4 0.85 24 2.48 10.4 233 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 30.3 0.94 26 3.04 13.0 367 136 32.9 0.97 26 3.12 13.3 379 140 33.9 1.00 24 3.14 13.4 383 141 32.4 0.90 23 3.09 13.2 375 139 29.9 0.87 24 3.02 12.9 364 134 31.8 0.85 25 3.14 13.4 388 148 34.4 0.88 24 3.22 13.7 400 153 35.5 0.92 23 3.24 13.8 404 154 34.6 0.73 20 3.19 13.6 396 151 31.9 0.71 21 3.12 13.3 384 147 30.6 1.00 24 3.18 13.8 396 138 31.6 1.00 22 3.20 13.9 400 139 30.1 1.00 24 3.15 13.7 392 137 27.8 0.96 24 3.08 13.4 380 132 31.2 1.00 25 3.25 14.1 426 147 32.2 1.00 23 3.27 14.2 430 148 30.8 0.94 23 3.22 14.0 422 145 28.4 0.90 23 3.14 13.6 409 141 32.7 0.91 24 3.35 14.5 450 160 33.7 0.96 23 3.38 14.6 454 162 32.9 0.76 20 3.32 14.4 445 159 30.3 0.74 20 3.24 14.0 432 154 34.9 0.74 21 3.46 15.0 469 171 35.9 0.78 20 3.49 15.1 474 172 35.1 0.57 16 3.43 14.9 465 169 32.4 0.55 16 3.35 14.5 451 164 28.4 1.00 23 3.28 14.5 437 143 29.2 1.00 21 3.31 14.6 442 144 27.9 1.00 22 3.26 14.4 433 141 25.7 0.97 23 3.18 14.0 420 137 28.9 1.00 23 3.36 14.8 471 152 29.8 1.00 21 3.38 15.0 475 153 28.5 0.94 22 3.33 14.7 466 150 26.3 0.91 22 3.25 14.4 452 146 30.3 0.92 22 3.46 15.3 497 166 31.2 0.96 21 3.49 15.4 502 167 30.4 0.77 19 3.43 15.2 492 164 28.1 0.74 19 3.35 14.8 477 159 67 31.4 0.81 18 3.46 15.3 497 166 32.3 0.75 19 3.58 15.8 518 176 33.3 0.78 19 3.61 15.9 524 178 32.5 0.57 15 3.55 15.7 513 175 30.0 0.55 15 3.46 15.3 498 169 71 33.5 0.60 14 3.58 15.8 518 176 33.9 28.3 28.8 30.2 32.2 26.2 26.7 28.0 29.8 0.69 1.00 0.97 0.88 0.71 1.00 0.98 0.89 0.72 21 26 26 24 21 24 24 23 20 3.24 3.10 3.17 3.27 3.37 3.21 3.27 3.38 3.49 13.8 13.5 13.7 14.2 14.6 14.2 14.5 14.9 15.4 405 384 413 436 455 424 457 482 503 158 134 142 155 165 138 147 161 171 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 36.7 0.71 21 3.32 14.2 417 163 37.8 0.75 20 3.35 14.3 421 164 37.0 0.55 16 3.29 14.1 413 161 34.1 0.53 16 3.21 13.7 401 156 63 29.4 1.00 21 3.36 14.8 471 152 115 COOLING OPERATION Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7+/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 35.1 35.9 38.3 41.0 34.3 35.0 37.4 40.0 33.5 34.2 36.5 39.0 32.6 33.4 35.6 38.1 31.0 31.7 33.9 36.2 28.7 S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 Delta T 23 22 19 15 23 22 19 15 24 22 19 15 23 22 20 16 22 23 19 15 20 1292 KW 2.56 2.61 2.69 2.77 2.75 2.80 2.89 2.98 2.91 2.97 3.06 3.16 3.05 3.12 3.22 3.32 3.18 3.25 3.35 3.46 3.28 AMPS 10.7 11.0 11.3 11.6 11.5 11.7 12.0 12.4 12.3 12.6 12.9 13.4 13.1 13.3 13.7 14.2 13.8 14.1 14.5 15.0 14.5 HI PR 242 261 275 287 272 292 309 322 309 333 351 366 352 379 400 417 396 426 450 469 437 LO PR 114 121 132 141 121 128 140 149 125 133 145 155 132 140 153 163 138 147 160 171 143 MODEL: GPH1336M41* COOLING PERFORMANCE DATA GPH1336M41* EXPANDED PERFORMANCE DATA * 75 70 38.1 0.70 19 2.84 12.4 225 105 35.1 0.67 19 2.77 12.2 218 102 39.9 0.83 21 2.88 12.6 229 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 41.0 0.74 19 2.94 12.9 247 114 39.4 0.58 16 2.89 12.7 242 111 36.4 0.56 17 2.83 12.4 234 108 40.6 0.61 16 2.91 12.8 244 113 44.4 0.56 16 3.02 13.2 260 124 43.2 0.40 12 2.98 13.0 255 122 39.9 0.39 13 2.91 12.7 248 118 44.5 0.42 12 3.00 13.1 258 123 47.7 0.36 11 3.11 13.6 272 132 - - 38.9 0.86 21 3.09 13.5 257 113 37.2 0.72 19 3.04 13.3 252 111 34.3 0.70 19 2.97 13.0 244 107 38.3 0.76 18 3.06 13.4 255 112 40.1 0.77 19 3.15 13.8 277 120 38.5 0.60 16 3.10 13.5 271 118 35.6 0.58 17 3.03 13.2 263 114 39.7 0.63 16 3.12 13.7 274 119 43.4 0.58 16 3.24 14.1 292 131 42.2 0.42 13 3.19 13.9 286 129 39.0 0.40 13 3.12 13.6 278 125 43.5 0.44 12 3.22 14.0 289 130 46.6 0.38 11 3.34 14.6 305 140 - - 38.0 0.88 21 3.27 14.5 292 117 36.3 0.74 19 3.22 14.2 287 115 33.5 0.72 19 3.14 13.9 278 112 37.4 0.78 18 3.24 14.4 290 116 MBh 38.7 39.8 43.1 46.3 37.8 38.9 42.1 45.2 36.9 S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 Delta T 22 20 16 11 22 20 17 11 22 1300 KW 2.86 2.92 3.00 3.09 3.06 3.12 3.22 3.32 3.24 AMPS 12.5 12.8 13.1 13.5 13.4 13.7 14.0 14.5 14.4 HI PR 227 244 258 269 255 274 289 302 290 LO PR 106 113 123 131 112 119 130 138 116 MBh 35.7 36.8 39.8 42.7 34.9 35.9 38.9 41.7 34.1 S/T 0.77 0.68 0.52 0.33 0.79 0.71 0.54 0.35 0.81 Delta T 22 20 17 11 22 21 17 12 22 1139 KW 2.80 2.85 2.93 3.02 2.99 3.05 3.14 3.24 3.17 AMPS 12.3 12.5 12.8 13.2 13.1 13.3 13.7 14.1 14.0 HI PR 220 237 250 261 247 266 281 293 281 LO PR 103 109 119 127 108 115 126 134 113 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction access fittings. 1461 1139 1300 1461 39.2 0.73 18 2.86 12.5 227 106 MBh S/T Delta T KW AMPS HI PR LO PR 42.4 0.60 16 3.44 15.2 332 136 41.2 0.43 13 3.38 15.0 326 134 38.0 0.41 13 3.31 14.6 316 130 42.4 0.45 12 3.41 15.1 329 135 38.0 41.1 0.75 0.57 20 17 3.31 3.41 14.7 15.1 312 329 124 135 35.1 38.0 0.73 0.55 21 17 3.23 3.33 14.3 14.7 302 319 120 131 (TVA) conditions 39.1 0.79 19 3.34 14.8 315 125 37.6 0.62 16 3.28 14.5 308 122 34.7 0.60 17 3.21 14.2 299 119 38.7 0.65 16 3.31 14.7 312 124 44.1 0.37 11 3.52 15.6 343 144 40.7 0.35 12 3.43 15.2 333 139 45.5 0.39 11 3.55 15.7 347 145 - - 36.0 0.87 22 3.40 15.2 330 122 33.2 0.84 23 3.32 14.8 320 118 37.1 0.91 21 3.43 15.3 333 123 35.4 0.77 19 3.38 15.1 327 121 32.7 0.74 19 3.30 14.7 317 117 36.5 0.80 18 3.40 15.2 330 122 34.2 0.75 21 3.39 15.2 344 126 37.1 0.78 20 3.47 15.5 355 130 38.2 0.82 20 3.50 15.6 358 131 36.7 0.64 17 3.45 15.4 351 129 33.9 0.62 17 3.37 15.0 341 125 37.8 0.67 16 3.47 15.5 355 130 40.1 0.59 17 3.58 16.0 375 142 37.0 0.57 17 3.50 15.6 364 137 41.3 0.62 16 3.61 16.1 379 143 40.2 0.44 13 3.55 15.8 371 140 37.1 0.43 13 3.47 15.5 360 136 41.4 0.46 12 3.58 16.0 375 142 35.2 0.95 21 3.57 16.2 375 129 33.6 0.80 19 3.51 15.9 367 127 31.0 0.77 19 3.43 15.5 356 123 34.6 0.83 18 3.54 16.0 371 128 36.3 0.85 19 3.64 16.5 403 137 34.9 0.66 16 3.58 16.3 395 135 32.2 0.64 17 3.50 15.9 383 131 35.9 0.70 16 3.61 16.4 399 136 39.3 0.64 16 3.76 17.0 426 150 38.2 0.46 12 3.70 16.7 417 147 35.2 0.44 13 3.61 16.3 405 143 39.3 0.48 12 3.73 16.9 422 148 42.1 0.41 11 3.88 17.6 444 160 - - 32.6 0.96 20 3.68 17.0 414 134 31.2 0.80 18 3.63 16.7 406 131 28.8 0.77 18 3.54 16.3 394 127 32.1 0.84 17 3.65 16.9 410 132 63 33.6 0.86 18 3.76 17.4 446 142 32.3 0.67 15 3.70 17.1 437 139 29.8 0.65 16 3.61 16.7 424 135 33.3 0.70 15 3.73 17.2 441 141 67 36.4 0.65 15 3.88 17.9 471 155 35.4 0.46 12 3.82 17.6 461 152 32.7 0.45 12 3.73 17.2 447 148 36.4 0.49 11 3.85 17.8 466 154 39.0 0.42 10 4.01 18.5 491 165 - - 71 43.1 34.2 35.2 38.1 40.9 31.7 32.6 35.3 37.9 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40 12 22 20 16 11 20 19 15 11 3.69 3.54 3.61 3.73 3.84 3.66 3.73 3.85 3.97 16.5 16.0 16.4 16.9 17.4 16.9 17.2 17.8 18.4 391 371 399 422 440 410 441 466 486 151 128 136 149 158 132 141 154 164 39.7 31.6 32.5 35.2 37.8 29.2 30.1 32.6 35.0 0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.60 0.38 12 22 20 17 12 21 19 16 11 3.61 3.45 3.53 3.64 3.75 3.57 3.64 3.76 3.88 16.1 15.7 16.0 16.5 17.0 16.5 16.8 17.3 17.9 379 360 387 409 427 398 428 452 471 146 124 132 144 153 128 136 149 159 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 44.4 0.40 11 3.72 16.6 395 152 - - 115 COOLING OPERATION Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MODEL: GPH1342M41* COOLING PERFORMANCE DATA GPH1342M41* 19 20 EXPANDED PERFORMANCE DATA * 85 40.1 0.91 26 2.90 12.7 232 108 37.0 0.88 26 2.84 12.4 225 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1300 1139 37.7 0.85 26 2.89 12.7 242 111 40.9 0.88 25 2.96 13.0 249 115 42.1 0.92 24 2.98 13.1 252 116 39.5 0.77 24 2.98 13.0 255 122 42.8 0.80 24 3.05 13.3 263 125 44.1 0.83 23 3.07 13.4 266 127 42.1 0.62 21 3.07 13.4 266 129 45.6 0.65 21 3.14 13.8 274 134 47.0 0.68 20 3.16 13.9 277 135 36.1 0.91 27 3.04 13.3 252 111 39.1 0.95 26 3.11 13.6 260 114 40.3 0.99 25 3.13 13.7 262 115 36.8 0.88 26 3.10 13.5 271 118 39.9 0.91 26 3.17 13.9 280 121 41.1 0.96 25 3.20 14.0 282 123 38.6 0.79 25 3.19 13.9 286 128 41.8 0.82 24 3.27 14.3 295 132 43.0 0.86 23 3.29 14.4 298 134 41.2 0.64 21 3.29 14.4 299 137 44.6 0.67 21 3.37 14.7 308 141 45.9 0.70 20 3.40 14.8 311 142 35.3 0.94 27 3.22 14.2 287 115 38.2 0.97 26 3.29 14.6 295 119 39.4 1.00 25 3.32 14.7 298 120 36.0 0.90 26 3.28 14.5 308 122 39.0 0.94 26 3.36 14.9 318 126 40.1 0.98 25 3.39 15.0 321 127 37.7 0.81 25 3.38 14.9 326 134 40.8 0.84 24 3.47 15.3 336 138 42.0 0.89 23 3.49 15.4 339 139 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 1461 41.3 0.96 25 2.92 12.8 234 109 MBh S/T Delta T KW AMPS HI PR LO PR 40.2 0.66 21 3.49 15.4 340 142 43.5 0.69 21 3.57 15.8 350 147 44.8 0.72 20 3.60 15.9 354 148 34.4 0.97 27 3.38 15.1 326 121 37.3 1.00 26 3.46 15.4 336 124 38.4 1.00 24 3.48 15.6 340 126 35.1 0.93 26 3.45 15.4 351 128 38.0 0.97 26 3.53 15.8 362 132 39.1 1.00 25 3.56 15.9 366 134 36.7 0.84 25 3.55 15.8 371 140 39.8 0.87 25 3.64 16.2 382 145 41.0 0.91 24 3.67 16.4 386 146 32.7 1.00 26 3.51 15.9 367 127 35.4 1.00 25 3.59 16.3 379 130 36.5 1.00 23 3.62 16.4 382 132 33.3 0.97 26 3.58 16.3 395 135 36.1 1.00 26 3.67 16.7 407 139 37.2 1.00 23 3.70 16.8 411 140 34.9 0.87 25 3.69 16.7 417 147 37.8 0.91 24 3.79 17.1 430 152 38.9 0.95 23 3.82 17.3 434 153 37.2 0.71 21 3.81 17.3 435 157 40.3 0.73 21 3.91 17.7 449 161 41.5 0.77 20 3.94 17.9 453 163 30.3 1.00 24 3.62 16.7 406 131 32.8 1.00 23 3.71 17.2 418 135 33.8 1.00 21 3.74 17.3 422 136 30.9 0.98 24 3.70 17.1 437 139 33.4 1.00 24 3.79 17.5 450 144 34.4 1.00 22 3.82 17.7 455 145 32.3 0.88 23 3.82 17.6 461 152 35.0 0.91 23 3.91 18.0 475 157 36.1 0.96 22 3.94 18.2 480 158 67 36.3 0.80 18 3.91 18.0 475 157 35.2 0.76 19 3.88 17.9 471 155 32.5 0.74 19 3.79 17.5 456 151 34.5 0.71 20 3.94 18.2 481 162 37.4 0.74 20 4.04 18.7 496 167 38.5 0.78 19 4.07 18.8 501 169 71 38.8 0.60 15 4.04 18.7 496 167 37.6 0.57 15 4.01 18.5 491 165 34.7 0.55 15 3.91 18.0 476 160 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 39.2 0.68 22 3.66 16.4 387 149 42.5 0.71 21 3.75 16.8 399 154 43.7 0.74 20 3.78 16.9 403 156 63 33.9 1.00 21 3.79 17.5 450 144 32.9 0.94 22 3.76 17.4 446 142 30.4 0.90 22 3.67 17.0 432 138 115 COOLING OPERATION Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 40.6 41.5 44.3 47.3 39.6 40.5 43.3 46.2 38.7 39.5 42.2 45.1 37.7 38.6 41.2 44.0 35.9 36.6 39.1 41.8 33.2 S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 Delta T 23 22 19 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 1461 KW 2.90 2.96 3.05 3.14 3.11 3.17 3.27 3.37 3.29 3.36 3.47 3.57 3.46 3.53 3.64 3.75 3.59 3.67 3.79 3.91 3.71 AMPS 12.7 13.0 13.3 13.8 13.6 13.9 14.3 14.7 14.6 14.9 15.3 15.8 15.4 15.8 16.2 16.8 16.3 16.7 17.1 17.7 17.2 HI PR 232 249 263 274 260 280 295 308 295 318 336 350 336 362 382 399 379 407 430 449 418 LO PR 108 115 125 134 114 121 132 141 119 126 138 147 124 132 145 154 130 139 152 161 135 MBh 39.4 40.2 43.0 46.0 38.5 39.3 42.0 44.9 37.6 38.4 41.0 43.8 36.6 37.4 42.8 34.8 35.6 38.0 40.6 32.2 40.0 S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.55 0.99 0.93 0.76 0.57 1.00 0.73 Delta T 24 23 20 16 25 24 20 16 25 24 20 16 25 24 16 24 23 20 16 23 21 3.61 80 1300 KW 2.88 2.94 3.02 3.11 3.09 3.15 3.24 3.34 3.27 3.34 3.44 3.55 3.43 3.50 3.72 3.57 3.64 3.76 3.88 3.68 16.1 AMPS 12.6 12.9 13.2 13.7 13.5 13.8 14.1 14.6 14.5 14.8 15.2 15.7 15.3 15.6 16.6 16.2 16.5 17.0 17.6 17.0 HI PR 229 247 260 272 257 277 292 305 293 315 332 347 333 359 395 375 403 426 444 414 379 LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 152 129 137 150 160 134 143 MBh 36.4 37.1 39.7 42.4 35.5 36.3 38.8 41.4 34.7 35.4 37.8 40.5 33.8 34.6 36.9 39.5 32.1 32.8 35.1 37.5 29.8 S/T 0.84 0.79 0.64 0.48 0.87 0.82 0.66 0.50 0.89 0.84 0.68 0.51 0.92 0.86 0.70 0.53 0.96 0.90 0.73 0.55 0.96 Delta T 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 23 1139 KW 2.82 2.87 2.96 3.04 3.02 3.08 3.17 3.27 3.19 3.26 3.36 3.46 3.35 3.42 3.52 3.64 3.48 3.55 3.67 3.78 3.60 AMPS 12.3 12.6 12.9 13.3 13.2 13.4 13.8 14.3 14.1 14.4 14.8 15.3 15.0 15.3 15.7 16.2 15.8 16.1 16.6 17.1 16.6 HI PR 222 239 253 264 249 268 284 296 284 305 322 336 323 348 367 383 364 391 413 431 402 LO PR 104 110 120 128 110 117 127 135 114 121 132 141 120 127 139 148 125 133 146 155 130 MODEL: GPH1342M41* COOLING PERFORMANCE DATA GPH1342M41* EXPANDED PERFORMANCE DATA * 75 70 44.2 0.76 18 3.26 13.6 238 108 40.8 0.73 18 3.19 13.3 231 104 46.3 0.90 20 3.31 13.8 243 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 47.7 0.81 18 3.38 14.1 261 117 45.9 0.63 16 3.33 13.8 256 114 42.3 0.61 16 3.25 13.5 249 111 47.2 0.66 15 3.36 14.0 259 116 51.6 0.61 15 3.49 14.5 276 127 50.2 0.44 12 3.43 14.2 271 125 46.4 0.42 12 3.35 13.9 262 121 51.7 0.46 11 3.46 14.4 273 126 55.4 0.39 10 3.60 14.9 288 136 - - 45.3 0.94 20 3.56 14.7 273 116 43.2 0.79 18 3.51 14.5 267 114 39.9 0.76 18 3.42 14.2 259 110 44.5 0.82 17 3.53 14.6 270 115 46.6 0.84 19 3.64 15.1 293 123 44.8 0.66 16 3.58 14.8 288 121 41.3 0.63 16 3.50 14.5 279 117 46.1 0.69 15 3.61 14.9 290 122 50.4 0.63 15 3.75 15.5 310 135 49.1 0.45 12 3.69 15.2 304 132 45.3 0.44 12 3.60 14.9 294 128 50.5 0.48 11 3.72 15.4 307 133 54.1 0.41 11 3.87 16.0 323 143 - - 44.2 0.96 20 3.78 15.9 310 121 42.2 0.81 18 3.72 15.6 304 118 38.9 0.78 18 3.63 15.2 295 115 43.4 0.85 17 3.75 15.7 307 119 MBh 45.0 46.3 50.1 53.8 43.9 45.2 49.0 52.6 42.9 S/T 0.86 0.77 0.58 0.38 0.89 0.80 0.60 0.39 0.92 Delta T 21 19 16 11 21 19 16 11 21 1720 KW 3.29 3.36 3.46 3.57 3.53 3.61 3.72 3.84 3.75 AMPS 13.7 14.0 14.4 14.8 14.6 14.9 15.4 15.9 15.7 HI PR 241 259 273 285 270 290 307 320 307 LO PR 109 116 126 134 115 122 133 142 119 MBh 41.5 42.8 46.3 49.7 40.6 41.8 45.2 48.5 39.6 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.88 Delta T 21 19 16 11 21 20 16 11 21 1507 KW 3.21 3.28 3.38 3.48 3.45 3.52 3.63 3.75 3.66 AMPS 13.4 13.6 14.0 14.5 14.3 14.6 15.0 15.5 15.4 HI PR 233 251 265 277 262 282 298 310 298 LO PR 105 112 122 130 111 118 129 138 116 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction access fittings. 1933 1507 1720 1933 45.6 0.80 17 3.29 13.7 240 109 MBh S/T Delta T KW AMPS HI PR LO PR 49.2 0.65 15 3.99 16.7 352 140 47.9 0.47 12 3.92 16.4 345 137 44.2 0.45 12 3.83 16.0 335 133 49.3 0.49 11 3.95 16.5 349 139 44.2 47.8 0.82 0.62 19 16 3.83 3.95 16.1 16.6 330 349 127 139 40.8 44.1 0.79 0.60 20 16 3.74 3.86 15.7 16.1 320 338 123 134 (TVA) conditions 45.5 0.86 19 3.86 16.2 334 128 43.7 0.67 16 3.80 15.9 327 126 40.4 0.65 16 3.71 15.6 317 122 45.0 0.71 15 3.83 16.1 330 127 51.3 0.40 11 4.08 17.1 364 148 47.4 0.38 11 3.98 16.7 353 143 52.8 0.42 11 4.12 17.2 367 149 - - 41.9 0.95 21 3.94 16.7 350 125 38.6 0.91 21 3.85 16.3 339 122 43.1 0.99 20 3.98 16.8 353 127 41.2 0.83 18 3.91 16.6 346 124 38.0 0.80 19 3.82 16.2 336 120 42.4 0.87 18 3.94 16.7 350 125 39.8 0.82 20 3.93 16.6 365 129 43.1 0.85 19 4.03 17.1 376 133 44.4 0.89 19 4.06 17.2 380 135 42.7 0.69 16 4.00 16.9 372 132 39.4 0.67 16 3.90 16.5 361 128 43.9 0.73 15 4.03 17.1 376 133 46.6 0.64 16 4.16 17.6 397 146 43.0 0.62 16 4.06 17.1 385 141 48.0 0.67 15 4.19 17.7 401 147 46.7 0.48 12 4.12 17.4 393 144 43.1 0.46 12 4.02 17.0 381 140 48.1 0.50 12 4.16 17.6 397 146 41.0 1.00 19 4.14 17.8 397 133 39.1 0.86 18 4.07 17.5 389 130 36.1 0.83 18 3.97 17.1 378 126 40.3 0.91 17 4.11 17.6 393 131 42.2 0.92 18 4.23 18.2 427 141 40.5 0.72 16 4.16 17.9 419 138 37.4 0.70 16 4.06 17.4 406 134 41.7 0.76 15 4.20 18.0 423 140 45.6 0.70 15 4.37 18.7 451 154 44.4 0.50 12 4.30 18.4 442 151 41.0 0.48 12 4.19 18.0 429 146 45.7 0.52 11 4.33 18.6 447 153 49.0 0.45 10 4.51 19.4 471 164 - - 37.9 1.00 18 4.28 18.8 439 137 36.2 0.87 17 4.21 18.4 430 135 33.4 0.84 17 4.11 18.0 417 130 37.3 0.91 16 4.25 18.6 434 136 63 39.1 0.93 17 4.38 19.2 472 146 37.5 0.73 15 4.30 18.8 463 143 34.6 0.70 15 4.20 18.4 449 139 38.7 0.76 14 4.34 19.0 468 145 67 42.3 0.70 14 4.52 19.8 499 159 41.1 0.50 11 4.44 19.4 489 156 38.0 0.49 11 4.33 18.9 474 152 42.4 0.53 11 4.48 19.6 494 158 45.4 0.45 10 4.67 20.4 520 170 - - 71 50.1 39.8 40.9 44.3 47.6 36.8 37.9 41.0 44.0 0.41 0.98 0.88 0.66 0.43 0.99 0.89 0.67 0.43 11 21 19 16 11 19 18 15 10 4.29 4.11 4.20 4.33 4.48 4.25 4.34 4.48 4.63 18.2 17.7 18.0 18.6 19.2 18.6 19.0 19.6 20.3 414 393 423 447 466 435 468 494 515 155 131 140 153 162 136 145 158 168 46.2 36.7 37.8 40.9 43.9 34.0 35.0 37.9 40.7 0.40 0.95 0.85 0.64 0.41 0.95 0.85 0.65 0.42 11 21 20 16 11 20 18 15 10 4.19 4.01 4.09 4.22 4.36 4.14 4.23 4.37 4.52 17.7 17.2 17.6 18.1 18.7 18.1 18.5 19.1 19.8 402 382 411 434 452 422 454 479 500 150 127 136 148 158 132 140 153 163 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 51.6 0.43 11 4.33 18.3 419 157 - - 115 COOLING OPERATION Design Subcooling, 12 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 +/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MODEL: GPH1348M41* COOLING PERFORMANCE DATA GPH1348M41* 21 22 EXPANDED PERFORMANCE DATA * 85 54.7 0.73 19 3.65 15.2 294 139 46.9 1.00 22 3.62 15.0 278 118 47.8 1.00 23 3.70 15.3 299 126 50.0 0.94 22 3.81 15.7 316 137 53.4 0.76 19 3.93 16.3 330 146 45.8 1.00 22 3.84 16.1 316 123 46.6 1.00 22 3.93 16.5 340 131 48.8 0.96 22 4.05 17.0 359 143 43.3 1.00 23 4.01 17.0 357 128 40.0 1.00 24 3.91 16.6 346 124 51.2 0.91 22 3.54 14.7 282 130 MBh 46.6 47.5 49.7 53.1 45.5 46.4 48.6 51.8 44.4 45.3 47.4 50.6 S/T 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.92 0.74 Delta T 25 24 23 20 24 25 23 20 24 24 23 20 1720 KW 3.34 3.41 3.51 3.62 3.59 3.67 3.78 3.90 3.81 3.89 4.02 4.15 AMPS 13.9 14.2 14.6 15.1 14.9 15.2 15.6 16.1 16.0 16.3 16.8 17.4 HI PR 245 264 279 291 275 296 313 326 313 337 356 371 LO PR 111 118 129 137 117 125 136 145 122 130 141 151 MBh 43.0 43.8 45.9 49.0 42.0 42.8 44.8 47.8 41.0 41.8 43.8 46.7 S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 0.98 0.88 0.72 Delta T 25 25 23 20 25 25 24 20 25 25 24 20 1507 KW 3.26 3.33 3.43 3.54 3.51 3.58 3.69 3.81 3.72 3.80 3.92 4.05 AMPS 13.6 13.8 14.2 14.7 14.5 14.8 15.2 15.7 15.6 15.9 16.4 17.0 HI PR 238 256 270 282 267 287 304 317 304 327 345 360 LO PR 108 114 125 133 114 121 132 141 118 126 137 146 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 1933 48.9 1.00 23 3.44 14.3 267 119 44.6 1.00 21 4.04 17.1 360 129 48.0 1.00 23 3.37 14.0 248 112 52.1 0.78 19 4.18 17.5 375 152 MBh S/T Delta T KW AMPS HI PR LO PR 44.2 1.00 24 4.10 17.3 384 136 40.8 1.00 25 3.99 16.9 372 132 45.5 1.00 22 4.13 17.5 388 137 46.3 0.95 23 4.23 17.9 405 149 42.7 0.91 24 4.12 17.4 393 144 47.7 0.99 23 4.26 18.0 409 150 42.4 1.00 20 4.21 18.1 405 135 43.2 1.00 21 4.30 18.5 436 144 45.3 1.00 22 4.44 19.1 461 157 48.3 0.84 19 4.59 19.7 480 167 39.3 1.00 19 4.35 19.1 448 140 40.0 1.00 19 4.45 19.5 482 149 41.9 1.00 20 4.60 20.1 509 163 67 42.1 0.87 17 4.56 19.9 504 161 40.9 0.83 18 4.52 19.8 499 159 37.8 0.80 18 4.41 19.3 484 155 44.7 0.84 18 4.75 20.8 531 173 71 45.1 0.65 14 4.71 20.6 525 171 43.7 0.62 14 4.67 20.4 520 170 40.4 0.60 15 4.55 19.9 505 165 49.4 41.2 42.0 44.0 46.9 38.1 38.9 40.7 43.4 0.77 1.00 1.00 0.98 0.80 1.00 1.00 0.99 0.80 20 22 22 23 20 20 21 22 19 4.37 4.17 4.27 4.40 4.55 4.32 4.41 4.56 4.71 18.5 17.9 18.3 18.9 19.6 18.9 19.3 19.9 20.6 423 401 432 456 476 443 477 504 525 158 134 143 156 166 139 147 161 171 45.6 38.0 38.7 40.6 43.3 35.2 35.9 37.6 40.1 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78 21 23 24 23 20 21 22 22 19 4.26 4.07 4.16 4.30 4.44 4.21 4.30 4.44 4.59 18.0 17.5 17.9 18.4 19.1 18.4 18.8 19.4 20.1 410 389 419 442 461 430 463 489 510 153 130 138 151 161 134 143 156 166 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 50.8 0.81 19 4.40 18.6 427 160 63 39.5 1.00 19 4.41 19.3 477 147 38.3 1.00 20 4.38 19.2 472 146 35.4 0.98 21 4.27 18.7 458 142 115 COOLING OPERATION Design Subcooling, 12 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 +/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 47.2 48.2 51.5 55.0 46.1 47.1 50.3 53.8 45.0 46.0 49.1 52.5 43.9 44.8 47.9 51.2 41.7 42.6 45.5 48.6 38.6 S/T 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.59 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.86 0.64 1.00 Delta T 22 21 19 15 22 22 19 15 21 22 19 15 21 21 19 15 20 20 19 15 18 1933 KW 3.34 3.41 3.51 3.62 3.59 3.67 3.78 3.90 3.81 3.89 4.02 4.15 4.01 4.10 4.23 4.37 4.17 4.27 4.40 4.55 4.32 AMPS 13.9 14.2 14.6 15.1 14.9 15.2 15.6 16.1 16.0 16.3 16.8 17.4 17.0 17.3 17.9 18.5 17.9 18.3 18.9 19.6 18.9 HI PR 245 264 279 291 275 296 313 326 313 337 356 371 357 384 405 423 401 432 456 476 443 LO PR 111 118 129 137 117 125 136 145 122 130 141 151 128 136 149 158 134 143 156 166 139 MBh 45.8 46.8 50.0 53.4 44.7 45.7 48.8 52.2 43.7 44.6 47.7 51.0 42.6 43.5 49.7 40.5 41.3 44.2 47.2 37.5 46.5 S/T 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.00 0.94 0.77 0.57 1.00 0.97 0.59 1.00 1.00 0.82 0.61 1.00 0.79 Delta T 23 22 19 15 23 22 20 16 23 22 20 16 23 23 16 22 22 19 16 20 20 4.19 80 1720 KW 3.31 3.38 3.49 3.60 3.56 3.64 3.75 3.87 3.78 3.86 3.99 4.12 3.98 4.06 4.33 4.14 4.23 4.37 4.51 4.28 17.7 AMPS 13.8 14.1 14.5 14.9 14.7 15.1 15.5 16.0 15.9 16.2 16.7 17.2 16.8 17.2 18.3 17.8 18.2 18.7 19.4 18.8 HI PR 243 261 276 288 273 293 310 323 310 334 352 367 353 380 419 397 428 451 471 439 401 LO PR 110 117 127 136 116 123 135 143 121 128 140 149 127 135 157 133 141 154 164 137 147 MBh 42.3 43.2 46.1 49.3 41.3 42.2 45.1 48.2 40.3 41.2 44.0 47.0 39.3 40.2 42.9 45.9 37.3 38.2 40.8 43.6 34.6 S/T 0.91 0.86 0.70 0.52 0.94 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.04 0.97 0.79 0.59 1.05 Delta T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 1507 KW 3.24 3.30 3.40 3.51 3.48 3.55 3.66 3.78 3.69 3.77 3.89 4.01 3.88 3.96 4.09 4.22 4.04 4.13 4.26 4.40 4.18 AMPS 13.5 13.7 14.1 14.6 14.4 14.7 15.1 15.6 15.5 15.8 16.3 16.8 16.4 16.8 17.3 17.9 17.4 17.7 18.3 18.9 18.3 HI PR 236 254 268 279 264 285 301 313 301 324 342 356 343 369 389 406 385 415 438 457 426 LO PR 106 113 124 132 112 120 131 139 117 124 136 145 123 131 143 152 129 137 149 159 133 MODEL: GPH1348M41* COOLING PERFORMANCE DATA GPH1348M41* EXPANDED PERFORMANCE DATA * 75 70 53.3 0.70 19 4.01 16.9 239 105 49.2 0.67 19 3.92 16.5 232 101 55.8 0.83 21 4.07 17.1 244 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1800 1577 2023 57.5 0.74 19 4.15 17.5 262 113 51.0 0.56 17 4.00 16.8 249 108 55.2 0.58 16 4.09 17.2 257 111 56.9 0.61 16 4.12 17.3 260 112 62.2 0.56 16 4.28 18.0 277 124 55.8 0.39 13 4.12 17.3 263 118 60.5 0.40 12 4.21 17.7 272 121 62.3 0.42 12 4.25 17.8 274 123 66.7 0.36 11 4.41 18.6 289 132 - - - 54.5 0.86 21 4.37 18.3 274 113 48.0 0.70 20 4.20 17.6 260 107 52.0 0.72 19 4.30 18.0 268 110 53.6 0.76 18 4.34 18.2 271 112 56.1 0.77 20 4.46 18.7 294 120 49.8 0.58 17 4.29 18.0 280 114 53.9 0.60 17 4.39 18.4 289 118 55.6 0.63 16 4.43 18.6 291 119 60.7 0.58 16 4.60 19.3 311 131 54.5 0.40 13 4.42 18.5 296 124 59.1 0.42 13 4.53 19.0 305 128 60.9 0.44 12 4.56 19.1 308 130 65.2 0.38 11 4.75 19.9 324 139 - - - 53.2 0.88 21 4.64 19.7 311 117 46.9 0.72 20 4.46 18.9 296 111 50.8 0.74 19 4.56 19.4 305 115 52.3 0.78 19 4.60 19.6 308 116 MBh 54.2 55.8 60.4 64.8 52.9 54.5 59.0 63.3 51.7 S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 Delta T 22 20 17 11 22 20 17 12 22 1800 KW 4.04 4.12 4.25 4.38 4.34 4.43 4.56 4.71 4.60 AMPS 17.0 17.3 17.8 18.4 18.2 18.6 19.1 19.7 19.6 HI PR 241 260 274 286 271 291 308 321 308 LO PR 106 112 123 131 112 119 130 138 116 MBh 50.0 51.5 55.7 59.8 48.8 50.3 54.4 58.4 47.7 S/T 0.77 0.68 0.52 0.33 0.79 0.71 0.54 0.35 0.81 Delta T 22 21 17 12 23 21 17 12 23 1577 KW 3.95 4.03 4.15 4.28 4.24 4.32 4.46 4.60 4.49 AMPS 16.6 16.9 17.4 18.0 17.8 18.1 18.7 19.3 19.1 HI PR 234 252 266 277 263 283 299 311 299 LO PR 102 109 119 127 108 115 126 134 112 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA High and low pressures are measured at the liquid and suction access fittings. 2023 54.9 0.73 18 4.04 17.0 241 106 MBh S/T Delta T KW AMPS HI PR LO PR 59.3 0.60 16 4.88 20.8 354 136 53.2 0.41 13 4.69 19.9 336 129 57.7 0.43 13 4.81 20.4 346 133 59.4 0.45 12 4.84 20.6 350 135 53.2 57.6 0.75 0.57 20 17 4.70 4.85 20.0 20.6 331 350 123 135 49.1 53.1 0.73 0.55 21 17 4.59 4.73 19.5 20.1 322 340 120 131 (TVA) conditions 54.8 0.79 20 4.74 20.2 335 125 48.6 0.60 17 4.55 19.3 318 118 52.7 0.62 17 4.66 19.8 328 122 54.2 0.65 16 4.70 20.0 331 123 61.8 0.37 12 5.00 21.3 365 143 57.0 0.35 12 4.88 20.8 354 139 63.6 0.39 11 5.04 21.5 369 145 - - - 50.4 0.87 22 4.83 20.8 351 122 46.5 0.84 23 4.72 20.3 340 118 51.9 0.91 22 4.87 20.9 354 123 45.7 0.74 20 4.68 20.1 337 117 49.6 0.77 19 4.79 20.6 347 121 51.0 0.80 19 4.83 20.8 351 122 47.9 0.75 21 4.82 20.7 366 126 51.9 0.78 21 4.94 21.2 378 130 53.4 0.82 20 4.98 21.4 381 131 47.4 0.62 17 4.78 20.5 363 124 51.4 0.64 17 4.90 21.0 374 128 52.9 0.67 16 4.94 21.2 377 130 56.2 0.59 17 5.09 21.9 399 141 51.8 0.57 17 4.97 21.3 387 137 57.9 0.62 16 5.13 22.0 403 143 51.9 0.43 13 4.93 21.1 383 136 56.3 0.44 13 5.05 21.7 395 140 58.0 0.46 12 5.09 21.9 399 141 49.3 0.95 21 5.07 22.1 399 129 43.5 0.77 19 4.87 21.2 379 123 47.1 0.80 19 4.99 21.8 391 126 48.5 0.83 18 5.03 22.0 395 128 50.8 0.85 20 5.18 22.6 429 137 45.0 0.64 17 4.97 21.7 408 130 48.8 0.66 17 5.10 22.3 420 134 50.3 0.70 16 5.14 22.4 425 136 55.0 0.64 16 5.35 23.3 453 150 49.3 0.44 13 5.13 22.4 431 142 53.5 0.46 13 5.26 22.9 444 147 55.1 0.48 12 5.30 23.1 448 148 59.0 0.41 11 5.52 24.1 472 159 - - - 45.7 0.96 20 5.24 23.3 440 133 40.3 0.77 18 5.03 22.4 419 127 43.6 0.80 18 5.16 22.9 432 131 44.9 0.84 17 5.20 23.1 436 132 63 47.0 0.85 18 5.36 23.9 474 142 41.7 0.65 16 5.14 22.9 451 135 45.2 0.67 15 5.27 23.5 465 139 46.6 0.70 15 5.31 23.7 469 140 67 50.9 0.65 15 5.53 24.6 501 155 45.7 0.45 12 5.31 23.6 476 147 49.5 0.46 12 5.44 24.2 491 152 51.0 0.49 11 5.48 24.4 495 153 54.6 0.42 10 5.71 25.5 522 165 - - - 71 60.3 47.9 49.3 53.4 57.3 44.4 45.7 49.4 53.0 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40 12 22 20 17 12 21 19 16 11 5.26 5.03 5.14 5.30 5.48 5.20 5.31 5.49 5.67 22.6 22.0 22.5 23.1 23.9 23.1 23.7 24.4 25.2 416 395 425 449 468 436 469 496 517 151 128 136 148 158 132 140 153 163 55.6 44.2 45.5 49.3 52.9 40.9 42.1 45.6 49.0 0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.59 0.38 12 22 21 17 12 21 19 16 11 5.13 4.91 5.01 5.17 5.34 5.07 5.18 5.35 5.53 22.0 21.4 21.9 22.6 23.3 22.6 23.1 23.8 24.6 403 383 412 435 454 423 455 481 501 146 124 132 144 153 128 136 149 158 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 62.1 0.40 11 5.30 22.8 420 152 - - - 115 COOLING OPERATION Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7 +/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MODEL: GPH1360M41* COOLING PERFORMANCE DATA GPH1360M41* 23 24 EXPANDED PERFORMANCE DATA * 85 57.8 0.96 25 4.13 17.4 249 109 56.1 0.91 26 4.10 17.3 246 108 51.8 0.88 27 4.01 16.9 239 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1577 2023 1800 1577 52.8 0.85 26 4.09 17.2 257 111 57.2 0.88 26 4.19 17.6 265 115 58.9 0.92 25 4.22 17.8 268 116 52.0 0.79 24 4.06 17.1 255 110 55.3 0.77 25 4.21 17.7 271 121 59.9 0.79 24 4.31 18.1 280 125 61.7 0.83 23 4.35 18.3 283 126 55.6 0.64 21 4.18 17.6 269 120 59.0 0.62 21 4.34 18.3 283 129 63.9 0.64 21 4.45 18.7 292 133 65.8 0.68 20 4.48 18.9 295 135 59.4 0.48 17 4.31 18.1 280 128 50.6 0.91 27 4.30 18.0 268 110 54.8 0.95 26 4.41 18.5 276 114 56.4 0.99 25 4.44 18.6 279 115 49.7 0.87 25 4.27 17.9 265 109 51.6 0.88 26 4.39 18.4 288 117 55.9 0.91 26 4.50 18.9 297 121 57.5 0.96 25 4.53 19.0 300 122 50.8 0.82 24 4.36 18.3 286 116 54.0 0.79 25 4.53 19.0 305 128 58.5 0.82 25 4.64 19.4 314 132 60.3 0.86 24 4.67 19.6 317 134 54.3 0.66 21 4.49 18.8 302 127 57.6 0.64 22 4.67 19.6 318 137 62.4 0.67 21 4.78 20.1 327 141 64.3 0.70 20 4.82 20.2 331 142 58.0 0.50 17 4.63 19.4 315 135 49.4 0.94 27 4.56 19.4 305 115 53.5 0.97 27 4.67 19.9 314 118 55.1 1.00 25 4.71 20.1 317 119 48.5 0.89 25 4.53 19.3 302 114 50.3 0.90 26 4.66 19.8 328 122 54.5 0.94 26 4.77 20.3 338 126 56.2 0.98 25 4.81 20.5 342 127 49.6 0.84 24 4.62 19.7 325 121 52.7 0.81 25 4.81 20.4 346 133 57.1 0.84 25 4.92 20.9 357 137 58.8 0.89 24 4.96 21.1 361 139 53.0 0.68 21 4.77 20.2 343 132 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 50.9 0.84 25 3.98 16.7 236 103 MBh S/T Delta T KW AMPS HI PR LO PR 56.2 0.66 22 4.96 21.1 361 142 60.9 0.69 21 5.08 21.6 372 146 62.8 0.72 20 5.12 21.8 376 148 56.6 0.51 17 4.92 20.9 358 141 48.2 0.97 27 4.79 20.6 347 121 52.2 1.00 27 4.91 21.1 358 124 53.8 1.00 24 4.95 21.3 361 126 47.3 0.92 25 4.75 20.4 344 119 49.1 0.93 27 4.89 21.0 374 128 53.2 0.97 26 5.02 21.6 385 132 54.8 1.00 25 5.06 21.8 389 134 48.4 0.86 24 4.86 20.9 370 127 51.4 0.84 25 5.05 21.7 395 140 55.7 0.87 25 5.18 22.2 407 144 57.4 0.91 24 5.22 22.4 411 146 51.7 0.70 21 5.01 21.5 391 139 45.8 1.00 27 4.99 21.8 391 126 49.6 1.00 25 5.11 22.3 403 130 51.1 1.00 23 5.15 22.5 407 132 45.0 0.96 25 4.95 21.6 387 125 46.7 0.97 26 5.10 22.3 420 134 50.5 1.00 26 5.22 22.8 433 139 52.1 1.00 24 5.27 23.0 438 140 46.0 0.90 24 5.05 22.1 416 133 48.9 0.87 25 5.26 22.9 444 147 52.9 0.90 24 5.39 23.5 458 151 54.5 0.95 24 5.44 23.7 462 153 49.1 0.73 21 5.22 22.7 439 145 52.1 0.71 22 5.43 23.7 463 156 56.5 0.73 21 5.57 24.3 477 161 58.2 0.77 20 5.61 24.5 482 163 52.5 0.55 17 5.39 23.5 458 155 42.4 1.00 25 5.16 22.9 432 131 45.9 1.00 23 5.29 23.5 445 135 47.3 1.00 21 5.33 23.7 449 136 41.7 0.96 23 5.12 22.8 427 129 43.2 0.98 25 5.27 23.5 464 139 46.8 1.00 24 5.40 24.1 479 143 48.2 1.00 22 5.45 24.3 484 145 42.6 0.90 22 5.23 23.3 460 138 45.3 0.88 23 5.44 24.2 490 152 49.0 0.91 23 5.58 24.8 506 156 50.5 0.96 22 5.62 25.0 511 158 45.5 0.74 20 5.39 24.0 486 150 67 50.8 0.80 18 5.58 24.8 506 156 49.3 0.76 19 5.53 24.6 501 155 48.3 0.71 20 5.62 25.0 511 162 52.3 0.74 20 5.76 25.7 527 167 53.9 0.78 19 5.81 25.9 533 168 48.6 0.55 16 5.57 24.8 506 160 71 54.3 0.60 15 5.76 25.7 527 167 52.7 0.57 15 5.71 25.5 522 165 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 54.9 0.68 22 5.21 22.4 411 149 59.4 0.71 21 5.35 23.0 424 154 61.2 0.74 21 5.39 23.2 428 155 55.3 0.53 17 5.17 22.2 407 148 63 47.5 1.00 22 5.40 24.1 479 143 46.1 0.94 22 5.36 23.9 474 142 115 COOLING OPERATION Design Subcooling, 9 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 7 +/-2 °F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 56.8 58.0 62.0 66.3 55.5 56.7 60.6 64.7 54.2 55.3 59.1 63.2 52.8 54.0 57.7 61.7 50.2 51.3 54.8 58.6 46.5 S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 Delta T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 2023 KW 4.10 4.19 4.31 4.45 4.41 4.50 4.64 4.78 4.67 4.77 4.92 5.08 4.91 5.02 5.18 5.35 5.11 5.22 5.39 5.57 5.29 AMPS 17.3 17.6 18.1 18.7 18.5 18.9 19.4 20.1 19.9 20.3 20.9 21.6 21.1 21.6 22.2 23.0 22.3 22.8 23.5 24.3 23.5 HI PR 246 265 280 292 276 297 314 327 314 338 357 372 358 385 407 424 403 433 458 477 445 LO PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 MBh 55.1 56.3 60.2 64.4 53.9 55.0 58.8 62.9 52.6 53.7 57.4 61.4 51.3 52.4 59.9 48.7 49.8 53.2 56.9 45.1 56.0 S/T 0.87 0.82 0.66 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.96 0.90 0.54 0.99 0.93 0.76 0.57 1.00 0.73 Delta T 25 24 20 16 25 24 21 17 25 24 21 17 25 24 17 25 24 21 16 23 21 5.14 80 1800 KW 4.07 4.15 4.28 4.41 4.37 4.46 4.60 4.75 4.64 4.74 4.88 5.04 4.87 4.98 5.30 5.07 5.18 5.35 5.52 5.24 22.0 AMPS 17.1 17.5 18.0 18.6 18.3 18.7 19.3 19.9 19.7 20.2 20.8 21.5 20.9 21.4 22.8 22.2 22.6 23.3 24.1 23.3 HI PR 244 262 277 289 274 294 311 324 311 335 354 369 354 381 420 399 429 453 473 440 403 LO PR 107 113 124 132 113 120 131 139 117 125 136 145 123 131 152 129 137 150 159 133 143 MODEL: GPH1360M41* COOLING PERFORMANCE DATA GPH1360M41* HEATING PERFORMANCE DATA GPH13[24-42]M41* EXPANDED PERFORMANCE DATA MODEL: GPH1324M41* HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 MBh 28.9 27.4 25.8 24.1 23.0 22.3 20.7 19.1 16.7 15.4 14.2 Delta T 32.4 30.7 28.9 27.0 25.8 25.0 23.2 21.4 18.8 17.3 15.9 KW 2.14 2.10 2.06 2.01 1.99 1.97 1.94 1.89 2.32 2.26 2.21 AMPS 10.4 9.8 9.2 8.8 8.5 8.4 8.0 7.7 7.4 7.1 6.9 COP 3.96 3.82 3.67 3.50 3.38 3.30 3.13 2.95 2.11 1.99 1.88 EER 13.5 13.1 12.5 12.0 11.5 11.3 10.7 10.1 7.2 6.8 6.4 HI PR 379 364 350 334 326 320 308 295 283 270 260 LO PR 135 126 118 108 102 98 90 80 73 65 57 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. 17 13.4 15.1 2.18 6.7 1.80 6.2 253 53 15 12.9 14.5 2.16 6.7 1.75 6.0 249 51 10 11.6 13.0 2.10 6.4 1.61 5.5 239 43 MODEL: GPH1330M41* MBh Delta T KW AMPS COP EER HI PR LO PR 65 36.2 31.9 2.74 13.6 3.87 13.2 375 131 60 34.3 30.2 2.68 12.7 3.74 12.8 359 122 5 10.3 11.5 2.05 6.1 1.47 5.0 230 37 0 9.0 10.1 2.00 5.8 1.31 4.5 221 31 -5 7.6 8.6 1.95 5.5 1.15 3.9 213 27 -10 6.3 7.0 1.89 5.1 0.97 3.3 205 22 HEATING OPERATION 55 32.3 28.4 2.63 12.0 3.59 12.3 346 114 50 30.2 26.6 2.58 11.4 3.42 11.7 330 105 47 28.8 25.4 2.55 11.1 3.30 11.3 323 99 45 27.9 24.6 2.53 10.9 3.23 11.0 316 95 Outdoor Ambient Temperature 40 35 30 25 25.9 23.9 21.2 19.6 22.9 21.1 18.7 17.3 2.48 2.43 2.29 2.24 10.4 9.9 9.6 9.2 3.06 2.88 2.71 2.55 10.5 9.8 9.2 8.7 304 292 280 267 88 78 70 63 20 18.0 15.9 2.19 8.9 2.40 8.2 256 55 17 17.0 15.0 2.17 8.7 2.30 7.9 250 51 15 16.4 14.4 2.15 8.6 2.23 7.6 246 49 10 14.7 13.0 2.10 8.2 2.05 7.0 236 42 5 13.0 11.5 2.05 7.8 1.86 6.4 227 36 0 11.4 10.0 2.00 7.5 1.66 5.7 218 30 -5 9.7 8.6 1.95 7.0 1.46 5.0 210 27 -10 7.9 7.0 1.90 6.5 1.22 4.2 203 21 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. MODEL: GPH1336M41* HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 MBh 43.0 40.7 38.3 35.8 34.2 33.1 30.8 28.4 24.4 22.6 20.8 Delta T 34.6 32.8 30.8 28.8 27.5 26.7 24.8 22.9 19.7 18.2 16.7 KW 3.10 3.04 2.98 2.92 2.89 2.86 2.81 2.75 2.36 2.31 2.26 AMPS 15.4 14.4 13.6 12.9 12.5 12.3 11.7 11.1 10.7 10.3 9.9 COP 4.06 3.92 3.76 3.58 3.46 3.39 3.21 3.02 3.03 2.86 2.69 EER 13.9 13.4 12.8 12.2 11.8 11.6 11.0 10.3 10.4 9.8 9.2 HI PR 403 386 371 355 347 340 327 314 300 287 276 LO PR 137 127 119 109 103 99 91 81 73 66 58 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. 17 19.6 15.8 2.24 9.7 2.57 8.8 269 54 15 18.9 15.2 2.22 9.6 2.50 8.5 264 52 10 17.0 13.6 2.17 9.2 2.29 7.8 254 44 MODEL: GPH1342M41* 5 15.0 12.1 2.12 8.7 2.08 7.1 244 38 0 13.1 10.6 2.07 8.3 1.85 6.3 234 32 -5 11.2 9.0 2.02 7.8 1.62 5.5 226 28 -10 9.2 7.4 1.97 7.2 1.36 4.6 218 22 HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 MBh 50.3 47.6 44.8 41.9 40.0 38.8 36.0 33.2 27.5 25.4 23.4 28.5 27.6 25.6 23.6 19.6 18.1 16.7 Delta T 35.8 33.9 31.9 29.8 3.45 3.38 3.34 3.31 3.25 3.18 2.31 2.27 2.23 KW 3.58 3.52 AMPS 17.6 16.5 15.6 14.8 14.3 14.1 13.4 12.8 12.3 11.9 11.4 3.50 3.42 3.24 3.05 3.48 3.27 3.07 COP 4.11 3.96 3.80 3.62 14.0 13.5 13.0 12.4 12.0 11.7 11.1 10.4 11.9 11.2 10.5 EER 323 310 298 285 278 273 262 252 241 230 221 HI PR LO PR 141 131 122 112 106 102 94 84 75 67 59 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. 17 22.1 15.7 2.20 11.2 2.94 10.0 216 55 15 21.3 15.1 2.18 11.1 2.85 9.7 212 53 10 19.1 13.6 2.14 10.6 2.61 8.9 204 45 5 16.9 12.0 2.09 10.0 2.36 8.1 196 39 14.8 10.5 2.05 9.6 2.11 7.2 188 33 -5 12.6 9.0 2.01 9.0 1.84 6.3 181 29 -10 10.3 7.3 1.96 8.3 1.54 5.3 175 22 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. 25 HEATING PERFORMANCE DATA GPH13[48-60]M41* EXPANDED PERFORMANCE DATA MODEL: GPH1348M41* HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 MBh 57.2 54.1 51.0 47.6 45.5 44.1 41.0 37.8 32.8 30.2 27.8 Delta T 30.8 29.1 27.4 25.6 24.5 23.7 22.0 20.3 17.6 16.3 15.0 KW 3.90 3.83 3.75 3.68 3.63 3.60 3.53 3.46 2.48 2.43 2.38 AMPS 19.0 17.7 16.7 15.8 15.3 15.0 14.3 13.7 13.1 12.6 12.1 COP 4.29 4.14 3.97 3.79 3.66 3.58 3.39 3.20 3.86 3.64 3.42 EER 14.7 14.1 13.6 13.0 12.5 12.2 11.6 10.9 13.2 12.4 11.7 HI PR 372 357 343 328 320 314 302 290 278 265 255 LO PR 130 121 113 104 98 95 87 77 70 62 55 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. 17 26.3 14.2 2.36 11.9 3.27 11.2 249 51 15 25.3 13.6 2.34 11.8 3.17 10.8 244 49 10 22.7 12.2 2.29 11.2 2.91 9.9 235 42 MODEL: GPH1360M41* 5 20.1 10.8 2.24 10.6 2.63 9.0 226 36 17.6 9.5 2.19 10.1 2.35 8.0 217 30 -5 15.0 8.1 2.14 9.5 2.05 7.0 209 26 -10 12.3 6.6 2.09 8.7 1.72 5.9 202 21 HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 MBh 69.8 66.0 62.2 58.1 55.5 53.8 50.0 46.1 39.1 36.1 33.3 Delta T 35.9 34.0 32.0 29.9 28.5 27.7 25.7 23.7 20.1 18.6 17.1 KW 4.80 4.71 4.62 4.53 4.47 4.44 4.35 4.26 2.41 2.36 2.32 AMPS 24.1 22.5 21.2 20.1 19.4 19.1 18.1 17.3 16.7 16.0 15.4 COP 4.25 4.10 3.94 3.76 3.63 3.55 3.36 3.17 4.76 4.47 4.19 EER 14.5 14.0 13.5 12.8 12.4 12.1 11.5 10.8 16.3 15.3 14.3 HI PR 385 369 354 339 331 325 312 300 287 274 263 LO PR 134 124 116 107 101 97 89 80 72 64 56 Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed. 17 31.4 16.2 2.30 15.0 4.00 13.7 257 52 15 30.3 15.6 2.28 14.9 3.88 13.2 252 50 10 27.1 14.0 2.24 14.2 3.54 12.1 243 43 5 24.1 12.4 2.20 13.4 3.20 10.9 233 37 21.0 10.8 2.16 12.8 2.84 9.7 224 31 -5 17.9 9.2 2.12 12.0 2.47 8.4 216 27 -10 14.7 7.5 2.08 11.0 2.06 7.1 208 21 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. 26 WIRING DIAGRAMS GPH13[24-42]M41AB LPS SEE NOTE #8 SEE NOTE #7 YL/PK BK 1 RD G YL BL EBTDR R XFMR-R YL C SPEED UP BL K1 NO K1 COM M1 NC M2 2 PU 3 BL 24V BK RD PU HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. C YL LVJB PU WH YL H C 3 F R-DFT RD DFT RCCF SA RD PLF 6 9 2 5 8 1 4 7 PU RD RD BL BK GR S C R 2 SPEED OPTIONAL COMP CHS FC RVC C COMPONENT LEGEND C COMP C C S 2 POLE ONLY SEE NOTE 7 HVDR RCCF H F S.A. CM SEE NOTE 5 EBTDR M2 BR 1 3 2 4 N O P 3 L F 1 SEE NOTE 2 M1 BR C CCR CH CHS CM COMP DC DFT EBTDR EM FC GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF R T1 EBTDR NC COM EM FC 208-240 SEE NOTE 4 SA TR 2 1 BK BK L2 CH T2 WARNING SEE NOTE #3 SUPPLY VOLTAGE 208-240/1/60 SEE NOTE 3 CHS RD CM FC L1 RD EM BR BK CH BK YL BR HIGH BR DFT SEE NOTE #3 RD T H E R M O S T A T CONTROL BOX PU BK LOW BK 3 SPEED ++ BK PU (COM) BK Y R G W1 O W2 C BR PU (TRANS240V) PU (M1) RD RD EM BR BR BL SEE NOTE #5 HPS YL RD GR WH OR BR BL RD R PU BL/PK BR WH HVDR BK BL/PK PU RD BK R DF1 RD YL W DF2 RD BK PU BK RD SEE NOTE #6 C PU O-RV LVDR L1 2 0 8 2 4 0 / 1 / 6 0 GND O CCR PU T1 BK OR BK OR CNT PS2 L2 PU BK C-RV R-PS1 DC BK BK 4 BR PU C C Y PU T2 3 2 RD BK Y RD RD 1 BL BL BL 208 240 C RD GR PU SEE NOTE 4 PU BK YL/PK BLOWER INTERLOCK RELAY CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ELECTRONIC BLOWER TIME DELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE BK BL BR GR OR PU RD WH YL WIRE CODE BLACK BLUE BROWN GREEN ORANGE PURPLE RED WHITE YELLOW 3 TR 24V EBTDR NOTES: R C G DFT RVC R C-RV O-RV R O W R-DFT DC Y R-PS1 DFT PS2 C CNT LPS 4 P L 5 F 6 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR "COM" WITH LEAD ON EBTDR "M1" OR "M2". 3. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TERMINAL 2 ON TRANSFORMER. 5. START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 6. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE. 7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION. 8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V). C HPS SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION R W2 O W1 Y THERMOSTAT G C 208-240/1/60 0140G01745-A Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WIRING DIAGRAMS GPH13[48-60]M41AB SEE NOTE 8 SEE NOTE 3 PU LPS SEE NOTE 7 BK PU PU YL/PK 1 2 3 C 208 240 YL/PK PU BL 24V YL BK BL RD C BL BL BK BK YL 2 0 8 2 4 0 / 1 / L2 T2 RD BL SEE NOTE 5 L1 T1 PU BK BL BK PU RD PU GR GND GR 60 Y C C C Y C-RV PU WARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. OR RD O PS2 CCR YL BK O-RV LVDR RD PU CNT R-PS1 DC PU OR RD RD BR WH PU GR WH W LVJB R YL BL BL DF2 WH H C F YL RD GR WH OR BR BL PLF BK R HVDR GR 3 6 9 2 5 8 1 4 7 R-DFT DF1 DFT RD YL RCCF RD BR RD BR PU YL RD BL/PK CONTROL BOX RD RD ++ BK BK PU SA SEE NOTE 4 WH GR R G W1 O W2 C YL PU RD PU BR BK BL/PK C L G N 1 2 3 4 5 SEE NOTE 6 PU CH BK YL RD RD BK CHS S C R DFT T H E R M O S T A T WH RD GR CM BK BK HPS EM BK COMP RVC BK SEE NOTE 6 SEE NOTE 2 L1 L2 SUPPLY VOLTAGE 208-240/1/60 T2 C R T1 C COMP C S 2 POLE ONLY SEE NOTE 7 COMPONENT LEGEND C CCR CH CHS CM COMP DC DFT EM GND HVDR LPS LVDR LVJB PLF RVC RCCF C H HVDR RCCF F S.A. CM SEE NOTE 4 SEE NOTE 6 CHS CH SEE NOTE 2 N L EM 3 G 1 SA TR HPS 2 SEE NOTE 3 1 2 O-RV C-RV W WIRE CODE BK BLACK BL BLUE BR BROW N GR GREEN OR ORANGE PU PURPLE RD RED WH W HITE YL YELLOW NOTES: DFT RVC O FIELD WIRING HIGH VOLTAGE LOW VOLTAGE 3 TR R FACT ORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGE 208-240 24V R CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT EVAPORATOR MOTOR EQUIPMENT GROUND HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SW ITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER HIGH PRESSURE SWITCH DFT R-DFT DC Y R-PS1 PS2 C CNT LPS HPS 2 3 1 EM C 4 5 SEE NOTE 2 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTO R SPEED MOVE W HITE AND YELLOW LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3 FOR 208 VOLT TRANSFORMER O PERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTORY EQUIPPED W HEN REQUIRED 5. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION. 8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V). 6 PLF C R W2 O W1 Y THERMOSTAT G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C 208-240/1/60 0140G01640-A Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 28