Download Dell OpenManage Server Administrator Version 2.3 Compatibility Guide
Transcript
Table 12-1. Resolved Issues for Server Agent Version 4.2.1 (continued) Problem Solution Intermittent incorrect fan probe readings of zero RPMs cause faulty alerts to be generated. Invalid fan probe readings also compromise the usability of Server Agent. Server Agent 4.2.1 prevents false alerts for fan probes based on incorrect readings of fan RPM values. This update also addresses usability issues caused by these incorrect fan RPM values. The incorrect fan RPM readings originate on PowerEdge systems that report systems management information to the management console using Server Agent version 4.0. Seven-character service tags display incorrectly. Formerly, certain combinations of characters and numbers in the seven-character service tag either did not display correctly or did not display at all. Server Agent 4.2.1 displays service tags correctly. False power supply fan readings. Server Agent Server Agent 4.2.1 corrects the problem of false reports high power supply fan RPM readings. The fan probe alerts. readings exceed the upper failure threshold and are reported as failures. Server Agent 4.2.0 The following subsections contain requirements, features, and open issues for Server Agent version 4.2.0. Release date: December 2000 Requirements Supported systems: Dell PowerEdge 300, 1300, 1400, 1550, 2300, 2400, 2450, 4300, 4350, 4400, 6300, 6350, 6400, 6450, 8450 Operating Systems • Red Hat Linux 7.0 (Kernel version: 2.2.16), Red Hat Linux SNMP agent: ucd-snmp version 4.1.2-8smux or later Historical Release Information for Legacy Systems 97