Download Dacor Food Warmer RWDV User's Manual
Transcript
DWD, ERWD, EWD, IWD, MRWD, MWDH, MWDV, OWD, RWDV Document # PG02-002 24”, 27”, 30”, 36” Wide Warming Drawers Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated DWD ERWD 3 1/2” (8.9 cm) 1” (2.5 cm) MRWD30B (only) 1 7/16” (3.7 cm) EWD 3 7/16” (8.7 cm) 1 1/8” (2.9 cm) All other MRWD series 1” (2.5 cm) Revised 01/18/12 Page 1/3 PLANNING GUIDE Electrical Circuit Required Total Connected Load Minimum Ambient Operating Temperature 120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit 4.0 Amp. @ 120 Vac, 60 Hz. 32°F (0°C) 1” (2.5 cm) 10 1/8” (25.7 cm) MWDH, MWDV, RWDV 3 1/4” (8.3 cm) A 1” (2.5 cm) Drawer Face Dimensions (MWD Series Shown) Handle Dimensions - side view Mounting hole 9 places 40” (101.6 cm) 3-prong 120 Vac power cord 9" (22.9 cm) 1/2" (1.3 cm) B C Chassis 10" (25.4 cm) Chassis without drawer inserted 1/2" (1.3 cm) 23 3/8” (59.4 cm) Chassis Dimensions (A) Drawer Face Width (B) Chassis Face Width (C) Chassis Width DWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) ERWD27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm) ERWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) EWD24 24” (61.0 cm) 23 5/8” (60.0 cm) 22 1/4” (56.5 cm) EWD27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm) EWD30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) EWD36 36” (91.4 cm) 35 5/8” (90.5 cm) 34 1/4” (87.0 cm) MRWD27 26 3/4” (67.9 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm) MRWD30 29 3/4” (75.6 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) MWDH27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm) MWDH30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) MWDV27 27” (68.6 cm) 26 5/8” (67.6 cm) 25 1/4” (64.1 cm) MWDV30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) RWDV30 30” (76.2 cm) 29 5/8” (75.2 cm) 28 1/4” (71.8 cm) Model 5/64" (2 mm) Drawer open 23 13/16” (60.5 cm) Overall Dimensions - Top View (EWD Series Shown) Warming Drawer Overall Dimensions All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 Document # PG02-002 DWD, ERWD, EWD, IWD, MRWD, MWDH, MWDV, OWD, RWDV Revised 01/18/12 Page 2/3 24”, 27”, 30”, 36” Wide Warming Drawers Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated C B Chassis PLANNING GUIDE Electrical Circuit Required Total Connected Load Minimum Ambient Operating Temperature 120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit 4.0 Amp. @ 120 Vac, 60 Hz. 32°F (0°C) E 5/16” (8 mm) D A Drawer open Drawer Face Dimensions (IWD/OWD Series Shown) F 40" (101.6 cm) 3 prong 120 Vac power cord Mounting hole, 9 places Overall Dimensions - IWD/OWD Series Top View ** ** ** ** G Chassis without drawer installed ** = OWD24 mounting holes Chassis Dimensions (IWD/OWD Shown) Model (A) Dimension Drawer Face Width (B) Dimension Chassis Width (C) Dimension Chassis Face Width IWD24 22 5/16” (56.7 cm) 22 1/4” (56.5 cm) 22 3/8” (56.8 cm) IWD27 25 5/16” (64.3 cm) 25 1/4” (64.1 cm) 25 3/8” (64.5 cm) IWD30 28 5/16” (71.9 cm) 28 1/4” (71.8 cm) 28 3/8” (72.1 cm) OWD24 22 1/2” (57.1 cm) 22 1/2” (57.1 cm) 22 1/2” (57.1 cm) All specifications subject to change without notice. (D) Dimension Drawer Face Height (E) Dimension Chassis Depth (F) Dimension Drawer Depth (G) Dimension Chassis Height 8 15/16” (22.7 cm) 23 3/8” (59.4 cm) 23 13/16” (60.5 cm) 9 1/16” (23.0 cm) 11 7/8” (30.2 cm) 20” (50.8 cm) 18” (45.7 cm) 11 7/8” (30.2 cm) www.dacor.com Phone: (800) 793-0093 DWD, ERWD, EWD, IWD, MRWD, MWDH, MWDV, OWD, RWDV Document # PG02-002 24”, 27”, 30”, 36” Wide Warming Drawers Cabinet/countertop tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated Warming drawer 36" typ. (91.4 cm) C PLANNING GUIDE warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • This appliance must be installed in accordance with the accompanying installation instructions. 3/4" min.* (1.9 cm) D 120 Vac electrical outlet Warming drawer C 3/4" min.* (1.9 cm) Mounting platform must be 3/4" (1.9 cm) thick and support 100 lbs. A B 1 1/2" (3.8 cm) Typical countertop Cooktop 27"/30"/36" Dacor single wall oven Warming drawer D Warming drawer 120 Vac elect. Warming drawer 120 Vac elect. C D Toe kick A Model DWD30 ERWD27 ERWD30 EWD24 EWD27 EWD30 EWD36**** IWD24 IWD27 IWD30 MRWD27 MRWD30 MWDH27 MWDH30 MWDV27 MWDV30 OWD24***** RWDV30 Revised 01/18/12 Page 3/3 36" typ. (91.4 cm) C A B C 3/4” min.* (1.9 cm) 120 Vac electrical outlet 3/4" min.* (1.9 cm) (A) Cutout Width 28 1/2” (72.4 cm) 25 1/2” (64.8 cm) 28 1/2” (72.4 cm) 22 1/2” (57.2 cm) 25 1/2” (64.8 cm) 28 1/2” (72.4 cm) 34 1/2” (87.6 cm) 22 1/2” (57.2 cm) 25 1/2” (64.8 cm) 28 1/2” (72.4 cm) 25 1/2” (64.8 cm) 28 1/2” (72.4 cm) 25 1/2” (64.8 cm) 28 1/2” (72.4 cm) 25 1/2” (64.8 cm) 28 1/2” (72.4 cm) 22 5/8” (57.5 cm) 28 1/2” (72.4 cm) (B) Min. Width to Adjacent Doors/ Drawers 30 1/4” (76.8 cm)* 27 1/4” (69.2 cm)* 30 1/4” (76.8 cm)* 24 1/4” (61.6 cm)* 27 1/4” (69.2 cm)* 30 1/4” (76.8 cm)* 36 1/4” (92.1 cm)* ** ** ** 27” (68.6 cm)* 30” (76.2 cm)* 27 1/4” (69.2 cm)* 30 1/4” (76.8 cm)* 27 1/4” (69.2 cm)* 30 1/4” (76.8 cm)* 24 1/4” (61.6 cm)*** 30 1/4” (76.8 cm)* (C) Cutout Height (D) Min. Vertical Gap Between Cutouts 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 9 1/8” (23.2 cm) 11 15/16” (30.3 cm) 9 1/8” (23.2 cm) 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* NA 1 1/16” (2.7 cm) 1 1/16” (2.7 cm) 1 1/16” (2.7 cm) 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* 1 1/4” (3.2 cm)* NA 1 1/4” (3.2 cm)* Min. Cutout Depth 24” (61.0 cm) 20 1/8” (51.1 cm) 24” (61.0 cm) * Bare minimum spacing to allow for ventilation and avoid scraping on DWD, ERWD, EWD, MRWD, MWDH, MWDV and RWDV series models. ** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller than the cutout. The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel must exceed the appropriate cutout dimensions (A and C above) to cover the hole. Allow 1/4" minimum additional space on the top, bottom and sides from the custom front panel edge to prevent scraping against adjacent doors, drawers and the countertop. *** OWD24 with optional factory front panel kit only. Bare minimum spacing shown to avoid scraping. Gap above and below cutout is 3/4” minimum. See ** above for OWD24 with custom front panel. **** Model EWD36 cannot be installed above or below another warming drawer (any type). ***** Model OWD24 cannot be installed above, below or adjacent to a wall oven or warming drawer (any type). All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093