Download A.O. Smith ATI-340H-N Technical Documents
Transcript
Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER ■ Primary Heat Exchanger is constructed of HRS35, a Commercial-Grade Copper that is more resilient to erosion. HRS35 is 25x better at heat transfer than stainless steel thus stabilizing outgoing water temperatures quicker ■ Secondary Heat Exchanger is made of Type 316L Stainless Steel to protect against corrosion CONTINUOUS MAXIMUM FLOW RATES UP TO 10.0 GPM ENERGY STAR® QUALIFIED AVAILABLE IN NATURAL GAS OR PROPANE (LP) ATI 540H & AT0 540H CAN BE USED IN BOTH RESIDENTIAL AND COMMERCIAL APPLICATIONS INDOOR MODELS ATI-240H, ATI-340H, ATI-540H ELECTRONIC IGNITION - NO PILOT LIGHT INDOOR MODEL - INCLUDES A BUILT-IN TEMPERATURE CONTROLLER AND ADVANCED DIAGNOSTICS TO SIMPLIFY TROUBLESHOOTING OUTDOOR MODEL - INCLUDES A WALL MOUNT TEMPERATURE REMOTE CONTROLLER AND ADVANCED DIAGNOSTICS TO SIMPLIFY TROUBLESHOOTING FACTORY-INSTALLED POWER CORD INCLUDED FOR INDOOR MODELS EASY-LINK UP TO 4 UNITS (540H MODELS ONLY) ■ With no additional parts or accessories needed MULTI-LINK UP TO 20 UNITS (540H MODELS ONLY) COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: ■ Air-Fuel Ratio (AFR) Sensor ■ Exhaust & Water Temperature Safety Control ■ Overheat Cut-Off Fuse OUTDOOR MODELS ATO-240H, ATO-340H, ATO-540H INTERNAL FREEZE PROTECTION SYSTEM POWER DIRECT VENT DESIGN ■ ■ ■ Exhaust, 3" PVC Venting up to 70 Feet or 4" PVC Venting up to 100 Feet Provides flexible venting with PVC, CPVC, or ABS Pipe for Intake and Exhaust (solid core only). Canadian Installations Require ULCS636 Listed PVC or CPVC Pipe for Venting. Category IV Stainless Steel venting can also be used 540 model only ACCESSORIES ■ ■ ■ ■ Pipe Cover Neutralizer Kit Isolation Valve Kits Concentric Termination WARRANTY ■ 15-year limited warranty on heat exchanger in residential applications ■ 10-year limited warranty on heat exchanger in commercial applications ■ 5-year limited warranty on all parts ® ANSI Z21.10.3 CSA 4.3 Page 1 of 6 Revised March 2013 AOSRG46835 Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS GAS CONSUMPTION INPUT MODEL NUMBER FUEL TYPE MINIMUM BTU/H MAXIMUM BTU/H INLET GAS PRESSURE DIMENSIONS IN INCHES HOT/COLD MINIMUM MAXIMUM ENERGY MAX AND W.C. W.C. FACTOR GPM* GAS CONN. A HEIGHT B WIDTH C DEPTH UNIT WEIGHT (LBS) INDOOR ATI-240H-N Natural 15,000 160,000 5.0 10.5 0.95 6.6 3/4” NPT 23-5/8 17-3/4 11-1/4 58 ATI-240H-P Propane 13,000 160,000 8.0 14.0 0.95 6.6 3/4” NPT 23-5/8 17-3/4 11-1/4 58 ATI-340H-N Natural 15,000 180,000 5.0 10.5 0.95 8.0 3/4"NPT 23-5/8 17-3/4 11-1/4 58 ATI-340H-P Propane 13,000 180,000 8.0 14.0 0.95 8.0 3/4"NPT 23-5/8 17-3/4 11-1/4 58 ATI-540H-N Natural 15,000 199,000 5.0 10.5 0.95 10.0 3/4"NPT 23-5/8 17-3/4 11-1/4 59 ATI-540H-P Propane 13,000 199,000 8.0 14.0 0.95 10.0 3/4"NPT 23-5/8 17-3/4 11-1/4 59 OUTDOOR ATO-240H-N Natural 15,000 160,000 5.0 10.5 0.95 6.6 3/4” NPT 23-5/8 17-3/4 11-1/4 58 ATO-240H-P Propane 13,000 160,000 8.0 14.0 0.95 6.6 3/4” NPT 23-5/8 17-3/4 11-1/4 58 ATO-340H-N Natural 15,000 180,000 5.0 10.5 0.95 8.0 3/4"NPT 23-5/8 17-3/4 11-1/4 58 ATO-340H-P Propane 13,000 180,000 8.0 14.0 0.95 8.0 3/4"NPT 23-5/8 17-3/4 11-1/4 58 ATO-540H-N Natural 15,000 199,000 5.0 10.5 0.95 10.0 3/4"NPT 23-5/8 17-3/4 11-1/4 59 ATO-540H-P Propane 13,000 199,000 8.0 14.0 0.95 10.0 3/4"NPT 23-5/8 17-3/4 11-1/4 59 All dimensions are in inches. 15-150 psi Water Pressure. 40 psi or above is recommended for maximum flow. *Current numbers based on factory testing; 0.4 GPM required for continuous fire after initial ignition. Indoor models are certified from sea level to 10,100 ft. elevations. In accordance with ANSI Z21.10.3, CO emission does not exceed 400 PPM for normal input. The manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligation. For Technical Information call 1-877-737-2840. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Page 2 of 6 AOSRG46835 Residential/Commercial Gas Tankless Water Heaters INDOOR MODEL 11-1/4" (285 mm) 4" (101 mm) ∅ 4" (102 mm) Female 5-3/4" (147 mm) Exhaust 2-5/8" (65 mm) ∅ 4" (102 mm) Female 22-1/2" (570 mm) 23-5/8" (600 mm) 24-7/8" (631 mm) 6-1/4" (159mm) Intake 2-5/8" (68 mm) 17-3/4" (450 mm) 7" (180 mm) 10-3/4" (272mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 120 VAC 3" (77 mm) COLD 5/8" (17 mm) 5-3/4" (147 mm) 17-5/8" (448 mm) Condensate drain port 7-7/8" (199 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) HOT 5-1/2" (140 mm) HOT 4-3/4" (120 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 120 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) COLD 5/8" (17 mm) 120 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-1/8" (131 mm) HOT 4-3/4" (120 mm) Drain port 6-3/4" (170 mm) 6-1/4" (159 mm) For Technical Information call 1-877-737-2840. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Page 3 of 6 AOSRG46835 Residential/Commercial Gas Tankless Water Heaters OUTDOOR MODEL 17-3/4" (450 mm) 7" (180 mm) 11-1/4" (285 mm) 11" (281 mm) 22-1/2" (570 mm) 3-5/8" (92 mm) 1-1/2" (37 mm) 23-5/8" (600 mm) 24-7/8" (631 mm) 4-1/2" (114 mm) 10-3/4" (272 mm) HOT 4-3/4" (120 mm) 120 VAC 6-1/4" (159 mm) Drain port 6-3/4" (170 mm) COLD 5/8" (17 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2" (13 mm) 120 VAC 3" (77 mm) GAS (131 mm) HOT (140 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (120 mm) Condensate drain port 7-1/2" (189 mm) 120 VAC 6-1/4" (159 mm) Condensate drain port 7-7/8" (199 mm) COLD 6-3/4" (172 mm) GAS 5-1/8" (131 mm) 120 VAC 3" (77 mm) HOT 5-1/2" (140 mm) 17-5/8" (448 mm) COLD 5/8" (17 mm) For Technical Information call 1-877-737-2840. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Page 4 of 6 AOSRG46835 Residential/Commercial Gas Tankless Water Heaters FLOW RATE vs TEMPERATURE RISE 240H 340H Flow Rate vs. Temperature Rise 10.0 10.0 9.0 9.0 8.0 8.0 Flow Rate (GPM) 11.0 7.0 6.0 5.0 4.0 3.0 7.0 6.0 5.0 4.0 3.0 2.0 2.0 1.0 1.0 0.0 0.0 0 20 40 60 80 0 100 20 40 60 80 100 Temperature Rise (°F) Temperature Rise (°F) 540H Flow Rate vs. Temperature Rise 11.0 10.0 9.0 8.0 Flow Rate (GPM) Flow Rate (GPM) Flow Rate vs. Temperature Rise 11.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0 20 40 60 80 100 120 140 Temperature TemperatureRise Rise(°F) (˚F) Set temperature 125˚F (52˚C) or lower Set temperature 130˚F (55˚C) or higher For Technical Information call 1-877-737-2840. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Page 5 of 6 AOSRG46835 Residential/Commercial Gas Tankless Water Heaters PRESSURE LOSS + + 3UHVVXUH /RVV 3UHVVXUH /RVV ϱϬ ϭϮϬ ϱϬ ϰϱ ϭϬϬ ϯϱ Ϯϱ ϲϬ ϮϬ ,ĞĂĚ ;&ĞĞƚͿ ϴϬ ϯϬ ϭϬϬ ϰϬ ϯϱ WƌĞƐƐƵƌĞ >ŽƐƐ ;ƉƐŝͿ ϰϬ ϴϬ ϯϬ Ϯϱ ϲϬ ϮϬ ,ĞĂĚ ;&ĞĞƚͿ ϰϱ WƌĞƐƐƵƌĞ >ŽƐƐ ;ƉƐŝͿ ϭϮϬ ϰϬ ϭϱ ϰϬ ϭϱ ϭϬ ϭϬ ϮϬ ϱ ϮϬ Ϭ ϱ Ϭ Ϭ Ϭ )ORZ 5DWH *30 )ORZ 5DWH *30 + 3UHVVXUH /RVV ,ĞĂĚ ;&ĞĞƚͿ WƌĞƐƐƵƌĞ >ŽƐƐ ;ƉƐŝͿ )ORZ 5DWH ;'WDͿ *30 &ůŽǁƌĂƚĞ 6HWWHPSHUDWXUHÛ)Û&RU ORZHU 6HWWHPSHUDWXUHÛ)Û&RUKLJKHU Specification Water heater(s) shall be Model_________________ as manufactured by A. O. Smith Water Heaters, shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested. The heater shall be vented with 3” or 4” Schedule 40 PVC, CPVC, or ABS vent pipe, or stainless steel Category III vent pipe at a distance not to exceed 70’ (equivalent) for 3” vent or 100’ (equivalent) for 4” vent, terminating vertically or horizontally as prescribed. Intake air pipe may be of such material as ABS, PVC, galvanized B-Vent, corrugated aluminum or stainless steel, or Category IV stainless steel not to exceed 70’ (equivalent) for 3” vent or 100’ (equivalent) for 4” vent. The heater(s) shall be controlled by an onboard solid-state printed circuit board monitoring incoming and outgoing temperatures with factory installed thermistors, sensing and controlling flow rate to set point temperature, controlling both air and gas mixture inputs to maintain thermal combustion efficiency. The heater(s) shall also consist of inline fusing, a spark ignition and sensor system, aluminized stainless steel burners, an air-fuel ratio sensor, a hi-limit temperature switch, modulating and proportional gas valves, a freeze protection sensor with ceramic heating blocks, and an overheat cutoff fuse. The water heater(s) shall be CSA listed, exceed the energy efficiency requirements of ASHRAE 90.1b-1992, and shall comply with SCAQMD Rule 1146.2 Ultra-Low NOx Standards. For Technical Information call 1-877-737-2840. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice. Page 6 of 6 www.hotwater.com AOSRG46835