INSTALLATION With the 1/4” UNC thread, the EYE-12 can be mounted onto a tripod. The UNC-threads can be found on the top and bottom sides. On the front, a filter/adapter lens can be attached: the M46x0.75. This is helpful i.e. when shorter distances than the MOD are necessary, a close-up lens can be attached (Minimum Optical Distance, Wide: 50mm and TELE: 500mm). When the EYE-12 is mounted into a housing (or ceiling) make sure to reserve space for the connected cables (about 50 to 100 mm, depending on the cable used). To mount the EYE-12 into suspended ceilings, use the optional available tile bridge. G IMPORTANT: Please give special attention to the specific country regulations for training and conferencing rooms. Failure to follow instructions can lead to severe injury! To avoid possible injury, ensure that the ceiling construction is able to support five times the required camera weight! For security reasons we are unable to provide fastening equipment for the ceiling mount with the camera. We request that you acquire the appropriate fastening material for your particular ceiling construction at your local hardware store. WolfVision will not take liability if substandard material is used or the installation is done incorrectly and not according to our instructions. [3 54.0 5/ 5 8" ] Dimensions USB TRIGGER LAN FREEZE 1 2 3 HELP 4 91.5 [3 5/8"] ZOOM MEMORY MENU 5 RS-232 IR-EXTERN RGB DVI 7 POWER AF 6 3 2 8 5 HELP 1 7 MEMORY 4 MENU FREEZE POWER 133.4 [5 1/4"] 123 [4 7/8"] 15 9 WHITE R C UN -20 1/4 IRIS ZOOM 61.5 [2 3/8"] Ø54.05 [Ø2 1/8"] 124.55 [4 7/8"] FOCUS 5 [1/4"] M 46x0.75 8 AF FOCUS WHITE IRIS 6 POWER 9