350-W Single Power Supply Input Voltages • 100 - 127 V at 50 / 60 Hz 6.0 A • 200 - 240 V at 50 / 60 Hz 3.0 A 350-W Single Power Supply Output Voltages Table 7 lists the total wattage available from the power subsystem for each voltage. For information about calculating the power usage for your configuration, see “Calculating Power Usage”. Table 7. Power Supply Output Capability Voltage 102 Maximum Current +3.3 V 6.8 A +5.0 V 10.9 A +5 V Standby 1.9 A +12.0 10.8 A -12.0 V 0.4 A Intel® Server System SR1630GPRX/SR1630HGPRX Service Guide