20 DTE Interface Signals CIRCUIT AB - SIGNAL GROUND CONNECTOR NOTATION: DGND DIRECTION: Not applicable This conductor directly connects the DTE circuit ground to the DCE circuit ground. CIRCUIT BA - TRANSMITTED DATA CONNECTOR NOTATION: TXD DIRECTION: To DCE This signal transfers the data generated by the DTE through the communication channel to one or more remote DCE data stations. CIRCUIT BB - RECEIVED DATA CONNECTOR NOTATION: RXD DIRECTION: From DCE This signal transfers the data generated by the DCE, in response to data channel line signals received from a remote DTE data station, to the DTE. CIRCUIT CA - REQUEST TO SEND CONNECTOR NOTATION: RTS DIRECTION: To DCE This signal controls the data channel transmit function of the local DCE and, on a half-duplex channel, the direction of the data transmission of the local DCE. CIRCUIT CB - CLEAR TO SEND CONNECTOR NOTATION: CTS DIRECTION: From DCE This signal indicates to the DTE whether the DCE is conditioned to transmit data on the communication channel.