Download ABUS FU8006 security or access control system
Transcript
3.5 Accessing the alarm centre In order to not trigger an alarm when leaving (Ext Time) or entering (Ent Time) the area, a delay time must be defined for accessing the centre in Partition 01. Access the installer menu and set the exit or entry delay under the “Partitions” menu item. In our example, the ground floor (Partition 01) is set as follows: Opening detector OD13-GF-HA Type: Final Exit Motion sensor MS4-GF-HA Type: Entry Route In the installer menu: When the house is exited, the system is activated within 10 seconds. When returning to the house, you have 120 seconds to disable the system. Æ Select the Partitions menu item. MS4-GF-HA Select Partions 01. Å Exit = 10 seconds C OD13-GF-HA Entrance = 120 seconds Æ Select the “Name” menu item, then enter a new name for the partition: Ground floor Select the type: Time Set 10 seconds for the exit delay time and 120 seconds for the entry delay time. You must deactivate the system within 120 seconds and may not enter any other areas where the detectors are not set to Entry Route. 18