Download Unitech MS337

Transcript
SCANNER OPERATION
Miscellaneous Decode Features
³
1
1
8
1
1
3
³
1
1
8
1
0
3
* Optional Same Symbol Check - Requires 1
different character between successive bar codes
to consider the bar code “new”.
Normal Same Symbol Check - Requires 3
different characters between successive bar codes
to consider the bar code “new”.
Same Symbol Time Outs
The length of time before a bar code can be rescanned after it is removed from
the scan field is user-configurable in increments of 50 msecs to 6350 msecs
(6.35 sec).
³
9
1
8
9
0
0
³
8
1
8
9
0
0
³
1
1
8
9
1
7
~ Variable Same Symbol Time Out - In configuration
mode, scan this bar code followed by the appropriate
code byte sequence to set the same symbol time out
duration.
No Same Symbol Time Out
Infinite Same Symbol Time Out - The scanner will
not repetitively scan the same bar code. This
option overrides the symbol rescan time-outs.
LED Options
³
1
1
8
3
1
3
³
1
1
8
3
0
3
³
1
1
8
3
1
2
³
1
1
8
3
0
2
Flash Green LED if Rescan Allowed - This
indicates same symbol timeout has elapsed.
* Do Not Flash Green LED if Rescan Allowed
Reverse LED Functions - Red = Laser On
Green = Good Read
* Normal LED Functions - Green = Laser On
Red = Good Read
5