Download NOTE - Motorola Solutions

Transcript
24 FPE Interface Specification
Example: <FS>B1Debit<FS>B2Credit
"C1" … "C30” - Pole display prompt 1 … Pole display prompt 30
Sets text to Pole display prompt. Optional.
9
NOTE: PDxxxx terminals process 1 to 30 pole display prompts. The length of the text which
can be displayed depends on terminal type and font used.
Field
Token
Parameter
Parameter
Description
Field ID
Scroll flag
Text to display
Example: <FS>C1NThis
Example: <FS>C2NThis
Example: <FS>C3NThis
Example: <FS>C4NThis
Example: <FS>C5NThis
Example: <FS>C6NThis
Example: <FS>C7YThis
9
text
text
text
text
text
text
text
Length
2-3
1
varies
goes
goes
goes
goes
goes
goes
goes
on
on
on
on
on
on
on
pole
pole
pole
pole
pole
pole
pole
Value
"C1" … "C30"
'Y' or 'N'
ASCII chars
display
display
display
display
display
display
display
line
line
line
line
line
line
line
one
two
three
four
five
six
seven
NOTE: If the Scroll flag is 'Y', any text at this screen position will be scrolled up to the next
screen position.
"DL" - Display Line
Allows displaying a specific format text line to the specific position of the screen. Optional.
9
NOTE: This token is processed on all types of terminals. The length of the text which can be
displayed depends on terminal type and font used.
Field
Description
Length
Value
Token
Field ID
2
"DL"
Parameter
Row
2
"00" - "15"
Parameter
Column
2
"00" - "42" Font dependant
Parameter
Display type
1
ASCII - Clear EOL 'C', Display Text 'D', Display
Text Blinking 'B', Display Text Marquee 'M'
Parameter
Delay
3
ASCII numeric - ms for marquee or blinking
"010" - "990" (10 ms increments)
Parameter
Foreground color
2
ASCII Hex "00" - "FF"
Parameter
Background color
2
ASCII Hex "00" - "FF"
Parameter
Font
1
ASCII numeric '0', '1', '2', '3', '4'
Text
Text to display
varies
Example: <FS>DL0112M10000FA2This text will marquee
“DT” – Screen saver timeout
Sets Screen saver timeout in second. Optional.
9
NOTE: This token is processed on PDxxxx terminals.
Field
Description
Length
Token
Field ID
2
Data
Timeout in seconds
1-9
Example: <FS>DT100
Value
“DT”
ASCII numeric